| Complementary |
| Synchronisation time between inputs | < 0.5 ms |
| Power dissipation in W | 3 W |
| Maximum number of I/O expansion module | 14 with 128 discrete output(s) for input; 14 with 32.0 discrete output(s) for output |
| Integrated connection type | Backplane expansion bus; USB 2.0 port |
| Data storage equipment | SD card (optional) |
| Inductive load | 2.4 mH |
| Load capacitance | 0.82 µF |
| Safety level | Can reach category 4 conforming to ISO 13849-1; Can reach PL = e conforming to ISO 13849-1; Type 4 conforming to IEC 61496-1; SILCL 3 conforming to IEC 62061 |
| Quality labels | CE |
| Local signalling | 1 LED green with PWR marking for power ON; 1 LED green with RUN marking for RUN (status); 1 LED red with E IN marking for internal error; 1 LED red with E EX marking for external error; 1 LED orange with COM marking for communication; 1 LED blue with EN marking for master enable; 8 LEDs yellow with IN marking for input status; 2 LEDs green/red with OUT marking for output status; 2 LEDs yellow with RST marking for restart signal; 2 LEDs yellow with STATUS marking for output channel |
| Connections - terminals | 2 captive screw terminals, removable terminal block; 1 captive screw terminals, removable terminal block |
| Mounting support | Omega 35 mm DIN rail conforming to EN 50022 |
| Depth | 114.5 mm |
| Height | 99 mm |
| Width | 22.5 mm |
| Net weight | 0.155 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | IEC 61496-1; ISO 13849-1; IEC 61508; IEC 61800-5-1; IEC 62061 |
| Product certifications | TÜV; RCM; cULus |
| IP degree of protection | IP20 |
| Ambient air temperature for operation | -10…55 °C |
| Ambient air temperature for storage | -20…85 °C |
| Relative humidity | 10…95 % |
| Pollution degree | 2 |
| [Uimp] rated impulse withstand voltage | 4 kV conforming to IEC 61800-5-1 |
| Safety reliability data | PFHd = 1.35E-8 1/h high; DC > 99 %; MTTFd < 100 years |
| Insulation | 250 V AC between power supply and housing conforming to IEC 61800-5-1 |
| Overvoltage category | II |
| Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2; Electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3; Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3 |
| Vibration resistance | +/-0.35 mm (f= 10…55 Hz) conforming to IEC 61496-1 |
| Shock resistance | 10 gn (duration = 16 ms) for 1000 shocks on each axis conforming to IEC 61496-1 |
| service life | 20 year(s) |
| Logistical informations |
| Country of origin | IT |
| Main |
| Range of product | Modicon Safety automation |
| Device short name | XPSMCM |
| Electrical connection | Screw terminal |
| Product or component type | Modular safety controller CPU kit |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Number of inputs | 8 digital for input connection; 4 digital for interlock start/restart or external device monitoring |
| Number of outputs | 4 safety outputs OSSD for contactor/drive connection; 4 test for line control outputs; 4 configurable for diagnostic connection |
| Discrete input voltage | 24 V |
| Discrete output current | 400 mA |
| Discrete input current | 400 mA |
| Discrete input type | Safety input; PNP |
| Discrete output type | PNP |
| Kit composition | 1 safety controller CPU; 1 backplane expansion connector |
| Backplane connector | With |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.500 cm |
| Package 1 Width | 12.500 cm |
| Package 1 Length | 16.000 cm |
| Package 1 Weight | 264.000 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 15.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 1.841 kg |