| Complementary |
| Synchronisation time between inputs | 0.5 s; 2 s |
| Type of start | Automatic/manual/monitored |
| Power consumption in W | 2 W 24 V DC |
| Power consumption in VA | 5 VA 24 V AC 50/60 Hz |
| Input protection type | Internal, electronic |
| safety outputs | 2 NO immediate; 1 NO configurable |
| safety inputs | 2 positive safety input 24 V DC 5 mA |
| maximum wire resistance | 500 Ohm |
| Time delay range | 0...900 s off delay |
| Input compatibility | Normally closed circuit conforming to ISO 14119; Mechanical contact conforming to ISO 14119; OSSD pair conforming to IEC 61496-1-2; Normally closed circuit conforming to ISO 13850; 3-wire proximity sensors PNP |
| [Ie] rated operational current | 5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact |
| control outputs | 3 on/off configurable pulsed output |
| Input/output type | Semiconductor output 24 V DC, 20 mA Z1, not safety-related |
| [Ith] conventional free air thermal current | 12 A |
| Associated fuse rating | 6 A gG for NO relay output circuit conforming to IEC 60947-1 |
| Minimum output current | 20 mA for relay output |
| Minimum output voltage | 24 V for relay output |
| Maximum response time on input open | 20 ms |
| [Ui] rated insulation voltage | 250 V (pollution degree 2) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category II conforming to IEC 60947-1 |
| Local signalling | LED green with power marking for power ON; LED red with error marking for error; LED yellow with state 1 marking for safety output instantaneous; LED yellow with state 2 marking for safety output delayed; LED yellow with start 1 marking for start; LED yellow with start 2 marking for start; LED yellow with S12 marking for safety input S12; LED yellow with S22 marking for safety input S22 |
| Mounting support | 35 mm symmetrical DIN rail |
| Depth | 120 mm |
| Height | 100 mm |
| Width | 22.5 mm |
| Net weight | 0.350 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | IEC 60947-5-1; IEC 61508-1 functional safety standard; IEC 61508-2 functional safety standard; IEC 61508-3 functional safety standard; IEC 61508-4 functional safety standard; IEC 61508-5 functional safety standard; IEC 61508-6 functional safety standard; IEC 61508-7 functional safety standard; ISO 13849-1 functional safety standard; IEC 62061 functional safety standard |
| Product certifications | TÜV; cULus |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529; IP40 (housing) conforming to IEC 60529; IP54 (mounting area) conforming to IEC 60529 |
| Ambient air temperature for operation | -25…55 °C |
| Ambient air temperature for storage | -25…85 °C |
| Relative humidity | 5…95 % non-condensing |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range of product | Harmony Safety Automation |
| Product or component type | Safety module |
| Safety module name | XPSBAT |
| Safety module application | For emergency stop and protective guard applications; For OSSD monitoring |
| Function of module | Emergency stop button with 2 NC contacts; Guard monitoring with 1 or 2 limit switches; Light curtain monitoring; RFID switch; Monitoring of electro-sensitive protection equipment (ESPE) |
| Safety level | Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1; Can reach SILCL 3 for normally open relay contact conforming to IEC 62061; Can reach SIL 3 for normally open relay contact conforming to IEC 61508; Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1; Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061; Can reach SIL 1 for normally closed relay contact conforming to IEC 61508 |
| Electrical circuit type | NC pair; OSSD pair |
| Connections - terminals | Removable screw terminal block, 0.2...2.5 mm² solid or flexible; Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor; Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor; Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel; Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel |
| [Us] rated supply voltage | 24 V AC - 15...10 %; 24 V DC - 20...20 % |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.800 cm |
| Package 1 Width | 13.800 cm |
| Package 1 Length | 15.500 cm |
| Package 1 Weight | 285.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.292 kg |
The Harmony XPS Basic safety relays implement basic safety functions. This device can be used to understand classic safety applications with a switch-off delay and to define the start function. The switch-off delay time and one of the two safety functions can be set on the rotary switches on the front. Mechanical break contacts from emergency stop/stop buttons, position, magnetic, pull-wire switches, as well as light curtains or RFID safety switches with OSSD outputs can be connected to the inputs. A safety function can be operated via the two inputs in a two-channel (redundant) version. Automatic, manual or monitored start is available on separate inputs for the start function. This safety switching device has 2 safe, undelayed relay make-contacts and optionally delayed 1 safe make-contact and 1 semiconductor signal output. The switch-off delayed time function (e.g. stop category 1 or 2, SS1 or SS2) can be set in steps from 0.1 second to 15 minutes. The supply voltage is 24 VAC and 24 VDC and the connections are made via removable screw terminals. Applications up to safety level PL e in category 4 or SIL3 can be realized. Installation is done by snapping onto a top hat rail or screwing onto mounting plates. A uniquely numbered locking strap is included to protect the settings under the transparent cover. A wide range of approvals enable international use. Thanks to the Green Premium environmental label, you can receive detailed information on material content, environmental impact and circular economy that supports your sustainability goals.