| Complementary |
| Synchronisation time between inputs | Unlimited |
| Type of start | Automatic/manual/monitored |
| Power consumption in W | 2.0 W 48...240 V DC |
| Power consumption in VA | 6.0 VA 48...240 V AC 50/60 Hz |
| Input protection type | Internal, electronic |
| safety outputs | 4 NO + 1 NC |
| safety inputs | 0 |
| Input compatibility | Normally closed circuit conforming to ISO 14119; XC limit switch conforming to ISO 14119; Mechanical contact conforming to ISO 14119; Normally closed circuit conforming to ISO 13850 |
| input terminal | Power supply |
| [Ie] rated operational current | 5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact; 3 A AC-1 for normally closed relay contact; 1 A AC-15 for normally closed relay contact; 3 A DC-1 for normally closed relay contact; 1 A DC-13 for normally closed relay contact |
| control outputs | 0 |
| [Ith] conventional free air thermal current | 6 A |
| Associated fuse rating | 10 A gG for NO relay output circuit conforming to IEC 60947-1 |
| Minimum output current | 10 mA for relay output |
| Minimum output voltage | 5 V for relay output |
| Response time | 60 ms at 48...240 V AC/DC |
| [Ui] rated insulation voltage | 300 V (pollution degree 2) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category II conforming to IEC 60947-1 |
| Local signalling | LED green with power marking for power ON; LED red with error marking for error; LED yellow with state marking for status; LED yellow with start1 marking for start input; LED yellow with start2 marking for start input |
| Mounting support | 35 mm symmetrical DIN rail |
| Depth | 120 mm |
| Height | 100 mm |
| Width | 22.5 mm |
| Net weight | 0.200 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Ambient air temperature for operation | -25…55 °C |
| Standards | IEC 60947-5-1; IEC 61508-1 functional safety standard; IEC 61508-2 functional safety standard; IEC 61508-3 functional safety standard; IEC 61508-4 functional safety standard; IEC 61508-5 functional safety standard; IEC 61508-6 functional safety standard; IEC 61508-7 functional safety standard; ISO 13849-1 functional safety standard; IEC 62061 functional safety standard |
| Product certifications | TÜV; cULus |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529; IP40 (housing) conforming to IEC 60529; IP54 (mounting area) conforming to IEC 60529 |
| Relative humidity | 5…95 % non-condensing |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range of product | Harmony Safety Automation |
| Product or component type | Safety module |
| Safety module name | XPSBAC |
| Safety module application | For emergency stop and protective guard applications |
| Function of module | Emergency stop button with 2 NC contacts; Guard monitoring with 1 or 2 limit switches |
| Safety level | Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1; Can reach SILCL 3 for normally open relay contact conforming to IEC 62061; Can reach SIL 3 for normally open relay contact conforming to IEC 61508; Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1; Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061; Can reach SIL 1 for normally closed relay contact conforming to IEC 61508 |
| Electrical circuit type | NC pair |
| Connections - terminals | Removable screw terminal block, 0.2...2.5 mm² solid or flexible; Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor; Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor; Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel; Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel |
| [Us] rated supply voltage | 48...240 V AC - 15...10 %; 48...240 V DC - 20...20 % |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.500 cm |
| Package 1 Width | 14.800 cm |
| Package 1 Length | 15.500 cm |
| Package 1 Weight | 306.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.623 kg |
The Harmony XPS Basic safety relays implement basic safety functions. The focus is on classic functions and easy operation with many switching contacts. It can be operated directly without any settings and has a realizable safety function. For this purpose, the mechanical break contacts of emergency stop/stop buttons, position or cable pull switches are integrated into the supply circuit of the safety relay. This means that the safety function can be implemented in a single or two-channel (redundant) version. Automatic, manual or monitored start is available on separate inputs for the start function. This safety switching device has 4 safe relay make contacts and 2 relay break contacts as outputs. The supply voltage is 48-240 VAC/DC and the connections are made via removable screw terminals. Applications up to safety level PL e in category 4 or SIL3 can be implemented. Installation is carried out by snapping onto a top hat rail or screwing onto mounting plates. A uniquely numbered locking strap is included to protect the settings under the transparent cover. A wide range of approvals enable international use. Thanks to the Green Premium eco-label, you can receive detailed information on material content, environmental impact and circular economy that supports your sustainability goals.