| Complementary |
| Fixing collar material | Zamak |
| Height | 50 mm |
| Width | 30 mm |
| Depth | 59 mm |
| Net weight | 0.13 kg |
| Resistance to high pressure washer | 7000000 Pa at 55 °C, distance : 0.1 m |
| Shape of signaling unit head | Rectangular |
| Type of operator | spring return |
| Operator profile | 1 flush - 1 projecting push-buttons - 1 central pilot light |
| Operators description | Green ''I'' - red ''O'' |
| Contacts type and composition | 1 NO + 1 NC |
| Contact operation | Slow-break |
| Contacts usage | Standard contacts |
| Positive opening | With conforming to IEC 60947-5-1 appendix K |
| Operating travel | 1.5 mm (NC changing electrical state); 2.6 mm (NO changing electrical state); 4.3 mm (total travel) |
| Operating force | 3.5 N NC changing electrical state; 3.8 N NO changing electrical state |
| Mechanical durability | 1000000 cycles |
| Connections - terminals | Screw clamp terminals, = 1 x 0.22 mm² without cable end conforming to IEC 60947-1 |
| Tightening torque | 0.8…1.2 N.m conforming to IEC 60947-1 |
| Shape of screw head | Cross compatible with JIS No 1 screwdriver; Cross compatible with Philips no 1 screwdriver; Cross compatible with pozidriv No 1 screwdriver; Slotted compatible with flat Ø 4 mm screwdriver; Slotted compatible with flat Ø 5.5 mm screwdriver |
| Contacts material | Silver alloy (Ag/Ni) |
| Short-circuit protection | 10 A cartridge fuse type gG conforming to IEC 60947-5-1 |
| [Ith] conventional free air thermal current | 10 A conforming to IEC 60947-5-1 |
| [Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
| [Ie] rated operational current | 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1; 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1; 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1; 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1 |
| Electrical durability | 1000000 cycles, AC-15, 2 A at 230 V, operating rate |
| Electrical reliability | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to IEC 60947-5-4; Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to IEC 60947-5-4 |
| Signalling type | Steady |
| Bulb base | Integral LED |
| [Us] rated supply voltage | 24 V AC/DC at 50/60 Hz |
| Supply voltage limits | 19.2…30 V DC; 21.6…26.4 V AC |
| Current consumption | 18 mA |
| Service life | 100000 h at rated voltage and 25 °C |
| Surge withstand | 1 kV conforming to IEC 61000-4-5 |
| Compatibility code | XB4 |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Protective treatment | TH |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -40…70 °C |
| Electrical shock protection class | Class I conforming to IEC 60536 |
| IP degree of protection | IP66 conforming to IEC 60529; IP69K conforming to IEC 60529; IP69 conforming to IEC 60529 |
| Enclosure Type | UL type 4X/13 |
| IK degree of protection | IK06 conforming to IEC 50102 |
| Standards | IEC 60947-1; IEC 60947-5-1; CSA C22.2 No 14; JIS C8201-5-1; IEC 60947-5-5; IEC 60947-5-4; UL 508; JIS C8201-1 |
| Product certifications | CSA; LROS (Lloyds register of shipping); BV; UL listed; DNV |
| Vibration resistance | 5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27; 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |
| Resistance to fast transients | 2 kV conforming to IEC 61000-4-4 |
| Resistance to electromagnetic fields | 10 V/m conforming to IEC 61000-4-3 |
| Resistance to electrostatic discharge | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2; 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 |
| Electromagnetic emission | Class B conforming to IEC 55011 |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range of product | Harmony XB4 |
| Product or component type | Illuminated double-headed push-button |
| Device short name | XB4 |
| Bezel material | Chromium plated metal |
| Head type | Standard |
| Mounting diameter | 22.5 mm |
| Colour of marking | White marking when green, red or black caps; Black marking when white caps |
| Light source | Protected LED |
| Light source colour | White |
| Device presentation | Complete product |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.500 cm |
| Package 1 Width | 5.500 cm |
| Package 1 Length | 9.000 cm |
| Package 1 Weight | 124.800 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 100 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 12.905 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 800 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 60.000 cm |
| Package 3 Weight | 111.240 kg |
The XB4BW73731B5 is an illuminated double pushbutton from the Harmony XB4 series by Schneider Electric, specifically designed for use in industrial and building technology applications. The device features a robust metal housing construction with chrome-plated bezel material and is designed for mounting in a hole with a diameter of 22.5 mm. It combines two actuation elements – a green button labeled 'I' and a red button labeled 'O' – along with a centrally positioned indicator light serving as a permanent signal lamp. The labeling is white on green, red, or black button plates, as well as black on white button plates, enabling clear visual distinction. The light source is a protected white LED, powered via an integrated holder. The supply voltage is 24 V AC/DC, with operating voltage ranging from 19.2 to 30 V DC and 21.6 to 26.4 V AC. The current consumption is 18 mA. The LED's service life is specified as 100000 hours under rated voltage and at a temperature of 25 °C.
Applications
This double pushbutton is suitable for applications requiring clear visual status indication and mechanical actuation, such as in manufacturing automation, building automation, or process control. The robust construction with protection class up to IP69K makes the device suitable for environments subject to high mechanical stress, moisture, or cleaning processes using high-pressure cleaners ( 7000000 Pa at 55 °C, distance 0.1 m). The operating temperature ranges from -40 °C to +70 °C, both for storage and operation, ensuring broad applicability in various climatic conditions.
Functions and Equipment in Detail
The device features a reset-type actuation, with the two buttons positioned differently: one is flush, the other protruding. The electrical equipment includes a normally closed contact (1Oe) and a normally open contact (1S), operated in a staged switching manner. The contacts are made of a silver alloy (Ag/Ni) and are designed for standard applications. The actuation forces are 3.5 N for the normally closed contact and 3.8 N for the normally open contact, with a total actuation stroke of 4.3 mm. The mechanical service life is specified as 1000000 cycles, while the electrical service life under AC-15 conditions at 2 A and 230 V is also 1000000 cycles. The contacts are protected by a 10 A cartridge fuse type gG, ensuring safe operational reliability.
Technology Explained Simply
The screw terminals on the rear of the device enable secure and reliable connections with cables from 0.22 mm², with tightening torques ranging from 0.8 to 1.2 Nm. The screw heads are compatible with Phillips screwdrivers types JIS No. 1, Philips No. 1, and Position No. 1, as well as flat screwdrivers with Ø 4 mm and Ø 5.5 mm. The rated insulation voltage is 600 V (pollution degree 3), the rated impulse voltage withstand is 6 kV, and the impulse voltage withstand is 1 kV according to IEC 61000-4-5. The conventional thermal current in free air is 10 A, and the rated operating currents are defined for various load types: 3 A at 240 V (AC-15), 6 A at 120 V (AC-15), 0.1 A at 600 V (DC-13), 0.27 A at 250 V (DC-13), 0.55 A at 125 V (DC-13), and 1.2 A at 600 V (AC-15). Electrical reliability is described by the failure rate Λ < 10exp(-6) at 5 V and 1 mA, and Λ < 10exp(-8) at 17 V and 5 mA in a clean environment.
Compatibility and Accessories
The device is part of the modular Harmony XB4 system, allowing it to be combined with various individual components. Suitable accessories include, for example, the labeling field ZBYLEG201001 (200x100 mm, adhesive type), the illuminated emergency stop/hold XB5AS84W3B41, the wall cabinet Sarel NSYS3D4420 (400x400x200 mm, RAL 7035), and the pushbutton XB4FA31 (30 mm, 1S, green). These components enable flexible adaptation to specific requirements and mounting conditions.
Mounting and Installation
Mounting is performed in a hole with a diameter of 22.5 mm, with the retaining flange made of Zamak. The connection terminals are located on the rear of the device and are designed for cable connections. Mounting is done via screw connection, with the specified tightening torques to be observed. The operating temperature range of -40 to +70 °C allows installation in a wide variety of environments, including industrial facilities with high temperature fluctuations.
Operational Advantages
The XB4BW73731B5 offers high mechanical and electrical service life, extending maintenance intervals and enhancing operational reliability. The integrated LED indicator enables clear status visualization, even in poorly lit environments. The IP69K protection class ensures high resistance to dust, water, and high-pressure cleaning, securing its use in demanding environments. The modular design allows flexible adaptation to different requirements, enabling use in both new installations and modernizations. Certifications and product standards enable international use. The Green Premium environmental label provides information on material contents, environmental impacts, and circular economy, supporting the implementation of sustainability goals.