Schneider Electric XALD363M, EAN: 3389110114515

Schneider Electric XALD363M enclosure 2 push buttons 1 indicator 230 V green red

Industrial Material > Control devices / Pilot devices > Built-Command and signaling devices

Schneider Electric XALD363M enclosure 2 push buttons 1 indicator 230 V green red

Lieske Part No. 960722
Mfg Part No XALD363M
EAN-Code 3389110114515
Manufacturer Schneider Electric
Here only 88,35 EUR
105,14 EUR incl. VAT

Further information for Schneider Electric XALD363M enclosure 2 push buttons 1 indicator 230 V green red

Complementary
AC control voltage 50 HZ230 V
Cable entry2 knock-outs for cable entry, clamping capacity: 14 mm; 2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12 mm
AC control voltage 60 HZ230 V
Net weight0.261 kg
DC control voltage125…600 V
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
Number of command positions2
Number of indicator lights1
Colour of markingWhite marking when green, red or black caps; Black marking when white caps
Number of push buttons2
Positive openingWith conforming to IEC 60947-5-1 appendix K
Operating travel1.5 mm (NC changing electrical state); 2.6 mm (NO changing electrical state); 4.3 mm (total travel)
Operating force3.5 N NC changing electrical state; 3.8 N NO changing electrical state
Mechanical durability10000000 cycles
Number of selector switches0
Connections - terminalsScrew clamp terminals, = 1 x 0.22 mm² without cable end conforming to IEC 60947-1
Tightening torque0.8…1.2 N.m conforming to IEC 60947-1
Number of key switches0
Shape of screw headCross compatible with Philips no 1 screwdriver; Cross compatible with pozidriv No 1 screwdriver; Slotted compatible with flat Ø 4 mm screwdriver; Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to IEC 60947-1
Number of mushroom-shaped push-buttons0
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
[Ie] rated operational current6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1; 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1; 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1; 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate
Electrical reliabilityΛ < 10exp(-6) at 5 V, 1 mA conforming to IEC 60947-5-4; Λ < 10exp(-8) at 17 V, 5 mA conforming to IEC 60947-5-4
Signalling typeSteady
Supply voltage limits195…264 V AC
Current consumption14 mA
Number of contacts as normally closed contact1
Service life100000 h at rated voltage and 25 °C
Surge withstand1 kV conforming to IEC 61000-4-5
Number of contacts as normally open contact1
Number of contacts as change-over contact0
Housing materialPlastic
Housing colourGrey
Emergency power offNo
Contractual warranty
Warranty (in months)18
Environment
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
Overvoltage categoryClass II conforming to IEC 60536
IP degree of protectionIP66 conforming to IEC 60529; IP67; IP69; IP69K
NEMA degree of protectionNEMA 13; NEMA 4X
IK degree of protectionIK05 conforming to IEC 62262
StandardsIEC 60947-1; IEC 60947-5-4; JIS C8201-5-1; CSA C22.2 No 14; IEC 60947-5-5; IEC 60947-5-1; UL 508; JIS C8201-1
Vibration resistance5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27; 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Resistance to fast transients2 kV conforming to IEC 61000-4-4
Resistance to electromagnetic fields10 V/m conforming to IEC 61000-4-3
Resistance to electrostatic discharge6 kV on contact (on metal parts) conforming to IEC 61000-4-2; 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
Electromagnetic emissionClass B conforming to IEC 55011
Logistical informations
Country of originFR
Main
Range of productHarmony XALD
Product or component typeComplete control station
Device short nameXALD
Product destinationFor XB5 Ø 22 mm control and signalling units
Control station applicationStart-Stop function
Colour of base of enclosureLight grey (RAL 7035)
Colour of coverDark grey (RAL 7016)
MaterialPolycarbonate
Operator profile2 flush push-buttons - 1 central pilot light
Operators descriptionGreen ''I'' 1 NO - red ''O'' 1 NC
Control station composition1 flush push-button, green 1 NO I marking; 1 flush push-button, red 1 NC O marking; 1 pilot light
Marking locationMarking on push-button
Contact operationSlow-break
Light sourceIntegrated and protected LED
Light source colourRed
[Us] rated supply voltage230 V AC
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.1 cm
Package 1 Width9.8 cm
Package 1 Length14.1 cm
Package 1 Weight289 g
Unit Type of Package 2S03
Number of Units in Package 225
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight7.713 kg
Unit Type of Package 3P06
Number of Units in Package 3200
Package 3 Height77 cm
Package 3 Width60 cm
Package 3 Length80 cm
Package 3 Weight70.916 kg
3 command points Light gray RAL 7 35 cover dark gray RAL 7
6
Indicator light, red, LED module, 23 V AC
Button sunk, green, symbol I,
S
Recessed pushbutton, red, symbol O,
NC Type: XALD363M item:
ST.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/960722
qrcode für Schneider Electric XALD363M enclosure 2 push buttons 1 indicator 230 V green red