| Complementary |
| Maximum braking power | 80 kW |
| Permanent braking power | 60 kW (at constant power and at engage threshold) |
| Load factor | 0.05 for 150 kW at constant power and at engage threshold; 0.15 for 120 kW at constant power and at engage threshold; 0.5 for 95 kW at constant power and at engage threshold; 1 for 75 kW at constant power and at engage threshold |
| Activation threshold | 395 V DC +/- 1 % |
| Maximum DC bus voltage | 450 V |
| Width | 216 mm |
| Height | 658 mm |
| Depth | 303 mm |
| Net weight | 15.5 kg |
| Volume of cooling air | 166 m3/h |
| Operating position | Vertical +/- 10 degree |
| Mechanical robustness | Vibrations class 3M4 conforming to IEC 60721-3-3 |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| IP degree of protection | IP20; IP21 (on top) |
| Ambient air temperature for operation | -10…50 °C |
| Ambient air temperature for storage | -40…70 °C |
| Main |
| Range compatibility | Altivar Process ATV900 |
| Product compatibility | Variable speed drive ATV930 without braking chopper 55 kW 200...240 V; Variable speed drive ATV930 without braking chopper 75 kW 200...240 V |
| Thermal losses | 400 W |
| Minimum resistor value to associate | 1.4 Ohm |
| Protection type | Integrated thermal protection by thermal probe |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 26.4 cm |
| Package 1 Width | 42.0 cm |
| Package 1 Length | 62.0 cm |
| Package 1 Weight | 21.5 kg |
Braking module for ATV930D55M3C - D75M3C frequency converters. Continuous power 60 kW, maximum power 80 kW, losses at continuous power 400 W, percentage of conduction time 5% at 150 kW, 15% at 120 kW, 50% at 95 kW, minimum resistance value 1 ¿. Supply voltage 200-240 V 50/60 Hz. Cable (converter - braking module), cross-section 3 x 120 mm², maximum length 10 m. Cable (braking module - resistors), cross-section 3 x 120 mm², maximum length 10 m. Braking modules allow Altivar Process frequency converters to operate during braking to a standstill or in generator mode by dissipating the energy in the braking resistor. Brake modules offer protection class IP 20. Thermal protection is provided by an integrated temperature sensor. Areas of application: machines with a large moment of inertia, machines with slow and fast cycles, high-performance machines performing vertical movements.