| Complementary |
| Electrical connection | Terminal 16 mm² 4 AWG |
| maximum earth leakage current | 7.6 mA at 400 V 50 Hz TN; 7.6 mA at 400 V 50 Hz TT |
| power supply voltage | 380…480 V; 200…240 V |
| Tolerance | 10 % |
| Mechanical robustness | Shocks class 3M4 conforming to IEC 60721-3-3; Vibrations class 3M4 conforming to IEC 60721-3-3 |
| Width | 90 mm |
| Height | 283 mm |
| Depth | 165 mm |
| Net weight | 5.2 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| IP degree of protection | IP20mounting side by side; IP21with kit VW3A47904 |
| Relative humidity | 5…95 % without condensation conforming to IEC 61800-5-1 |
| Ambient air temperature for operation | -10…50 °C (without current derating); 50…60 °C (with current derating 1.5 % per °C) |
| Ambient air temperature for storage | -40…70 °C |
| Operating altitude | 0...1000 m without current derating; 1000...4000 m with current derating 1 % per 100 m |
| Standards | IEC 61800-3 |
| Logistical informations |
| Country of origin | CN |
| Main |
| Range of product | Altivar |
| Product or component type | EMC input filter |
| Range compatibility | Altivar Process ATV900; Altivar Process ATV600 |
| Product specific application | Radio interference input filter |
| [In] rated current | 50 A |
| Thermal losses | 8 W |
| Network number of phases | Three phase |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 29.000 cm |
| Package 1 Width | 37.500 cm |
| Package 1 Length | 52.500 cm |
| Package 1 Weight | 6.242 kg |
| Unit Type of Package 2 | P06 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 75.000 cm |
| Package 2 Width | 60.000 cm |
| Package 2 Length | 80.000 cm |
| Package 2 Weight | 35.240 kg |
Three-phase supply voltage 200-240 V 50 Hz. EMC radio interference suppression filter, for frequency converter, for ATV630D11M3 converter, category C3, 50 m. Filter rated current 7.6 mA. The max. lengths are only examples as they vary according to the stray capacitance of the motors and cables used. For motors connected in parallel, the length of all cables must be taken into account. The values indicated depend on the nominal switching frequency of the converter. This frequency depends on the nominal size of the converter. Max. length of the shielded cable according to IEC/EN 61800-3 category C2 (50m). Max. length of the shielded cable according to IEC/EN 61800-3 category C3. For more stringent requirements, additional EMC input filters can be used. They reduce conducted emissions to values below category C1, C2 or C3 of the IEC/EN 61800-3 standard. The use of these additional filters is only possible in TN networks (connection to neutral conductor) or TT networks (connection of the neutral conductor to earth). According to the standard IEC/EN 61800-3, Appendix D2.1, filters in IT systems (isolated or neutral earthed impedance) can lead to the fact that the continuous insulation monitoring only takes place in random operation.