| Complementary |
| Product compatibility | Lexium 32M |
| Range compatibility | Altivar Process ATV600; Altivar Machine ATV340 except Sercos drives; Altivar 32; Altivar Machine ATV320; Lexium 32; Altivar Process Modular; Altivar Process ATV900 |
| Communication port protocol | CANopen, CANmotion |
| Electrical connection | 1 male connector SUB-D 9, CANopen, CANmotion |
| Contractual warranty |
| Warranty (in months) | 18 |
| Logistical informations |
| Country of origin | DE |
| Main |
| Range of product | Altivar |
| Product or component type | Communication module |
| Accessory / separate part category | Communication accessories |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.700 cm |
| Package 1 Width | 6.300 cm |
| Package 1 Length | 9.000 cm |
| Package 1 Weight | 73.000 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15 cm |
| Package 2 Width | 15 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 1.976 kg |
The communication module VW3A3618 from Schneider Electric is an integrated component of the Altivar product range, specifically designed for integrating drive systems into industrial control and automation networks. It serves as an interface for transmitting control and status information via the CANopen and CANmotion protocols, enabling bidirectional communication between the drive and higher-level control systems such as PLCs or SCADA systems. The module features a 9-pin SUB-D connector, serving as the physical interface and establishing the connection to CAN bus systems. This interface is designed for integration into existing industrial communication infrastructures, with CANopen and CANmotion protocols forming the basis for data transmission. CANopen is a widely used, open fieldbus protocol, particularly employed in automation technology, while CANmotion is specifically optimized for controlling drives and motion systems.
Applications
The module is intended for use in industrial environments, particularly in installations based on the Altivar product family. It is compatible with a wide range of drive systems, including Altivar Process ATV600, Altivar Machine ATV340 (excluding Sercos drives), Altivar 32, Altivar Machine ATV320, Lexium 32, Altivar Process Modular, and Altivar Process ATV900. Compatibility with the Lexium 32M series highlights its use in applications requiring high precision and reliability in motion control, such as manufacturing automation, packaging industry, or machine building. The communication card enables remote control, monitoring, and diagnostics of drives via the CAN bus network, enhancing system integration and maintenance efficiency.
Functions and Features in Detail
The module supports communication via CANopen and CANmotion protocols, making it suitable for both general control tasks and specific motion control applications. The connection is established through a 9-pin SUB-D connector, serving as a standard interface in industrial automation. This connector provides a mechanically robust and electrically reliable connection, designed for industrial environments. The communication card is designed as a plug-and-play component, installed into the corresponding drives of the Altivar family to extend their network capability. Integration requires no additional software or hardware modifications to the control system, as the protocols are standardized and supported by most industrial control systems.
Technology Explained Simply
The communication card acts as a bridge between the drive and the higher-level control system. Commands such as start, stop, speed adjustment, or positioning are transmitted to the drive via the CAN bus network, while status messages such as operating state, error codes, or actual values are returned. The CANopen and CANmotion protocols ensure structured and reliable data transmission, with CANmotion specifically optimized for precise control of motion sequences. The use of the SUB-D9 connector ensures a mechanically stable connection, resistant to vibrations and mechanical stress in production environments.
Compatibility and Accessories
The module is specifically developed for integration into drives from the Altivar product family, including models ATV600, ATV340 (excluding Sercos drives), ATV320, Altivar 32, Lexium 32, and ATV900. Compatibility with the Lexium 32M series emphasizes its use in high-precision motion applications. As accessories, various CANopen cables are available, including models with different lengths (50 m, 100 m, 300 m) and different protection ratings (IP20), as well as cables for harsh conditions. Additionally, termination resistors and various SUB-D9 sockets and plugs are available, facilitating cabling and integration into existing systems. These components enable flexible and application-specific network setups, with cable and connector selection based on environmental conditions and requirements for mechanical stability.
Installation and Mounting
Mounting is performed by installing the communication module into the corresponding Altivar drive. The exact installation instructions are provided in the respective drive manual for the relevant product series. The physical connection is made via the 9-pin SUB-D connector, which is connected to the CAN bus network. The electrical connection is established through the network, with the communication card functioning as part of the network. Configuration of communication parameters is done via the control system or using special configuration software provided by Schneider Electric. Installation does not require special tools, as the module is inserted into designated slots.
Operational Advantages
Integrating the communication module enables centralized control and monitoring of multiple drives via a common network, reducing system complexity and simplifying maintenance. The use of CANopen and CANmotion protocols ensures standardized and reliable communication, guaranteeing interoperability with various control systems. Remote control and diagnostics of drives via the network allow for faster fault detection and resolution, increasing operational uptime. The use of the SUB-D9 connector ensures a mechanically stable connection that functions reliably even under industrial loads. Compatibility with a broad range of Altivar drives makes the module a flexible solution for various automation applications.