| Complementary |
| Network pollution level | Polluted |
| [Gh/Sn] harmonic pollution rate | 25…50 % |
| [THDU] total harmonic distorsion of voltage | 4…7 % |
| Tuning factor | 3.8 |
| Tuning frequency | 190 Hz |
| Power per step | 50 kvar |
| Step composition | 2x50 + 7x100 |
| Location of connection | Bottom |
| Controller type | PowerLogic PFC Controller VPL12 |
| capacitor technology | PowerLogic PFC Capacitor + Detuned Reactor |
| Poles description | 3P |
| Capacitance tolerance | - 5 % to 10 % |
| [Ui] rated insulation voltage | 800 V |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Maximum permissible voltage | 1.1 x Un (8 hours over 24 hours) conforming to IEC 60831 |
| [Imp] maximum permanent current | Capacitor: 1.8 x In at 480 V conforming to IEC 60831; Battery: 1.19 x In at 400 V conforming to IEC 61439-2; Battery: 1.19 x In at 415 V conforming to IEC 61439-2 |
| main incomer protection | Circuit breaker protection |
| Breaking capacity | Icu 65 kA |
| Control type | Rotary handle |
| Step protection type | Overload: harmonic control from PowerLogic PFC Controller; Short-circuit: fuse |
| Accessibility for operation | Front |
| Colour | Grey (RAL 7035) |
| maximum weight | 1904 kg |
| Height | 2200 mm |
| Width | Capacitor: 1600 mm; Detuned reactor: 1200 mm |
| Depth | 600 mm |
| Provided equipment | Auxiliary transformer |
| Internal voltage transformer | 400/230 V - 1000 VA |
| Function available | GenSet shedding contact; Alarm contact |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | IEC 61921; IEC 61439-1; IEC 61439-2 |
| Product certifications | EAC; ASEFA; CE |
| Mounting location | Indoor |
| IP degree of protection | Environment: IP31; Safety: IPxx B |
| IK degree of protection | IK10 |
| Relative humidity | 0…95 % |
| Ambient air temperature for operation | -5…45 °C |
| Average ambient air temperature for operation | 35 °C (annual) ; 45 °C (over 24 hours) |
| Logistical informations |
| Country of origin | FR |
| Main |
| Network rated voltage | 400 V AC 50 Hz; 415 V AC 50 Hz |
| Reactive power rating | 800 kvar |
| Operating mode | Automatic |
| Range | PowerLogic |
| Device short name | automatic capacitor bank with detuned reactor |
| Product or component type | Capacitor bank |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 230 cm |
| Package 1 Width | 160 cm |
| Package 1 Length | 156 cm |
| Package 1 Weight | 1892 kg |
The low-voltage reactive power compensation from the PowerLogic PFC family helps to avoid contractual penalties from energy suppliers. Energy savings, lower operating costs and reduce CO² emissions through reactive power compensation of inductive loads. This hardware is compatible with the power management software to take advantage of the benefits of digital power supply and enable seamless integration into EcoStruxture Power. Intelligent monitoring and measurement functions are available for safe operation. To optimize operation and maintenance in a wide range of applications, both in commercial and industrial areas. This version, suitable for mains voltage 400V 50Hz, delivers reactive power up to 800kvar with a detuning factor of 7%. The compensation is automatically set by the reactive power controller of the PowerLogic PFC controller family. It is designed for mains harmonic voltages up to 7% or mains harmonic currents up to 20%, where the mains is defined as a polluted harmonic network. The PowerLogic PFC Capacitor Banks IEC range is certified to CE, IEC 61921, IEC 61439 Part 1 and IEC61439 Part 2. It contains capacitors with a long life expectancy from the PFC capacitor family, designed according to IEC831 Part 1 and IEC831 Part 2. And contain an intelligent controller with Modbus communication RS485. The RAL7035 enclosure is a floor standing system with a connection coming from below, protected by a circuit breaker. The external dimensions of the enclosure are 2 x 1400 mm width, 600 mm depth, 2200 mm height and a maximum product weight of 2x 952 kg. As standard, the enclosures are IP31. Optional kits are available to easily convert them to IP54. This product is particularly suitable for reactive power compensation applications with variable or unstable loads.