| Additional features |
| Network contamination level | Contaminated |
| [Gh/Sn] harmonic load | 25…50 % |
| [THDU] Total harmonic distortion of voltage | 4…7 % |
| Tuning factor | 4,2 |
| Tuning frequency | 210 Hz |
| Power per stage | 50 kvar |
| Step-by-step construction | 50 + 4 x 100 |
| Connector position | Bottom |
| Controller type | PowerLogic PFC controller VPL6 |
| Capacitor technology | PowerLogic PFC capacitor + filter choke |
| Pole description | 3P |
| Capacitor tolerance | -5 % to 10 % |
| [Ui] Rated insulation voltage | 800 V |
| [Uimp] Rated impulse voltage withstand | 8 kV |
| Max. permissible voltage | 1.1 x Un (8 hours over 24 hours) corresponds to IEC 60831 |
| [Imp] max. continuous current | Capacitor: 1.8 x inch at 480 V complies with IEC 60831; Battery: 1.31 x inch at 400 V complies with IEC 61439-2; Battery: 1.19 x inch at 415 V complies with IEC 61439-2 |
| Protection of main input switch | Without protection |
| [Icw] rated short-time current withstand | 35 kA at 1 s (Icw) |
| Step protection type | Overload: harmonic control by PowerLogic PFC controller; Short-circuit: fuse |
| Accessibility for operation | front side |
| Colour | Grey (RAL 7035) |
| Maximum weight | 952 kg |
| Height | 2200 mm |
| Width | Capacitor: 800 mm; detuned choke: 600 mm |
| Depth | 600 mm |
| Supplied accessories | Auxiliary transformer |
| Internal voltage converter | 400/230 V - 1000 VA |
| Function available | alarm contact; generator set ejection contact |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Supply voltage | 400 V AC 50 Hz; 415 V AC 50 Hz |
| Reactive power indication | 450 kvar |
| Operating mode | Automatic |
| Product series | PowerLogic |
| Device short name | Automatic capacitor bank with filter circuit choke |
| Product or component type | Capacitor bank |
| Mounting |
| Standards | IEC 61439-2; IEC 61921; IEC 61439-1 |
| Product certifications | ASEFA; EAC; CE |
| Mounting location | Indoor |
| Degree of protection (IP) | Environment: IP31; Safety: IPxx B |
| Degree of protection (IK) | IK10 |
| Relative humidity | 0…95 % |
| Operating ambient temperature | -5…45 °C |
| Average ambient air temperature for operation | 35°C (annual); 45°C (over 24 hours) |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 80,0 cm |
| VPE 1 width | 156,0 cm |
| VPE 1 length | 238,0 cm |
| Packaging weight (Lbs) | 635,0 kg |
The low-voltage reactive power compensation from the PowerLogic PFC family helps to avoid contractual penalties from energy suppliers. Energy savings, lower operating costs and reduce CO² emissions through reactive power compensation of inductive loads. This hardware is compatible with the power management software to take advantage of the benefits of digital power supply and enable seamless integration into EcoStruxture Power. Intelligent monitoring and measurement functions are available for safe operation. To optimize operation and maintenance in a wide range of applications, both in commercial and industrial areas. This version, suitable for mains voltage 400V 50Hz, delivers reactive power up to 450kvar with a detuning factor of 5.7%. The compensation is automatically set by the reactive power controller of the PowerLogic PFC controller family. It is designed for mains harmonic voltages up to 7% or mains harmonic currents up to 20%, where the mains is defined as a polluted harmonic network. The PowerLogic PFC Capacitor Banks IEC range is certified to CE, IEC 61921, IEC 61439 Part 1 and IEC61439 Part 2. It contains high life expectancy capacitors from the PFC capacitor family designed to IEC831 Part 1 and IEC831 Part 2. And contain an intelligent controller with Modbus communication RS485. The RAL7035 enclosure is a floor standing system with a connection coming from below. The external dimensions of the enclosure are 1400mm width, 600mm depth, 2200mm height and a maximum product weight of 952kg. As standard the enclosures are IP31. Optional kits are available to easily convert them to IP54. This product is particularly suitable for reactive power compensation applications with variable or unstable loads.