Mechanical durability30 Mcycles
Electrical durability2 Mcycles 9 A AC-3 at Ue 440 V; 1.2 Mcycles 15 A AC-1 at Ue 440 V
Maximum operating rate3600 cyc/mn AC-3
Operating time< 100 ms closing; < 30 ms opening
Safety performance levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Protection typeThermal overload protection; Motor overheat; Overcurrent; Undercurrent; Jam; Long start; Stall; Rapid cycle lockout; Phase sequence; Rapid restart lockout; Phase reversal; Phase loss; Phase unbalance; Ground current
Monitoring typeTime device ON; Time device switch ON; Number of faults; Number of switching cycles; Number of device power cycles; Average current Iavg; Average voltage Vavg; Max current Imax; Max voltage Vmax; Active and reactive power with voltage module; Active and reactive energy with voltage module; True power factor with voltage module
Local signalling1 LED (green/red) for DS (device status); 1 LED (green/red) for LS (load status)
StandardsEN/IEC 60947-1; EN/IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1
Product certificationsEAC; CSA; CCC; UL
Mounting modeHorizontal and vertical (35 mm symmetrical DIN rail)
Connections - terminalsScrew-clamp terminals 1 cable(s) 1…4 mm² (16 AWG...12 AWG) rigid; Screw-clamp terminals 2 cable(s) 1…4 mm² (16 AWG...12 AWG) rigid; Screw-clamp terminals 1 cable(s) 1.5…4 mm² (16 AWG...12 AWG) flexible without cable end; Screw-clamp terminals 2 cable(s) 1.5…4 mm² (16 AWG...12 AWG) flexible without cable end; Screw-clamp terminals 1 cable(s) 1…4 mm² (16 AWG...12 AWG) flexible with cable end; Screw-clamp terminals 2 cable(s) 1…2.5 mm² (16 AWG...14 AWG) flexible with cable end
Tightening torque1.7 N.m - with screwdriver flat Ø 6 mm; 1.7 N.m - with screwdriver Philips No 2
Width45 mm
Height116 mm
Depth115 mm
Net weight0.656 kg
Contractual warranty
Warranty (in months)18
Environment
Ambient air temperature for storage-25…70 °C
Ambient air temperature for operation-10…50 °C without derating; 50…60 °C with current derating
Relative humidity5…95 %
Operating altitude0...2000 m without derating
IP degree of protectionIP20
Pollution degree2
Protective treatmentTC
Fire resistance960 °C conforming to UL 94; 850 °C conforming to IEC 60695-2-1; 650 °C conforming to IEC 60695-2-12
Shock resistance15 gn (duration = 11 ms) conforming to IEC 60068-2-27
Vibration resistance1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Logistical informations
Country of originFR
Main
RangeTeSys
Product nameTeSys island
Device short nameTPRST
Product or component typeMotor starter
Motor starter typeDirect on line
Device presentationDirect starter connected to an automation controller through a bus coupler; Operational only when connected to a bus coupler
Function availableUpstream voltage presence detection; Electrical line and load protection; Power and energy monitoring when connected with TPRVM voltage module
Product compatibilityTPRBC bus coupler; TPRVM voltage interface module
Poles description3P (3 NO)
Utilisation categoryAC-1; AC-2; AC-3; AC-4; AC-3e
Motor power kW2.2 kW at 230 V 50 Hz (AC-3); 4 kW at 380...415 V 50 Hz (AC-3); 4 kW at 440 V 50 Hz (AC-3); 5.5 kW at 500 V 50 Hz (AC-3); 5.5 kW at 690 V 50 Hz (AC-3)
motor power HP (UL / CSA)0.33 hp at 120 V AC 60 Hz for 1 phase motors; 1 hp at 240 V AC 60 Hz for 1 phase motors; 2 hp at 208 V AC 60 Hz for 3 phases motors; 2 hp at 240 V AC 60 Hz for 3 phases motors; 5 hp at 480 V AC 60 Hz for 3 phases motors; 7.5 hp at 600 V AC 60 Hz for 3 phases motors
[Ie] rated operational current9 A (at
[Ith] conventional free air thermal current15 A (at 50 °C)
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
Overvoltage categoryIII
Thermal protection adjustment range0.18…9 A
Thermal overload classClass 5…30
ResetRemotely or automatically
Irms rated making capacity250 A at 440 V conforming to IEC 60947
Rated breaking capacity250 A at 440 V conforming to IEC 60947
[Icw] rated short-time withstand current210 A 40 °C - 1 s; 105 A 40 °C - 10 s; 61 A 40 °C - 1 min; 30 A 40 °C - 10 min
Average impedance2.5 mOhm - Ith 15 A 50 Hz
Power dissipation per pole0.2 W AC-3 - Ith 9 A; 0.56 W AC-1 - Ith 15 A
[Uc] control circuit voltage24 V DC supplied by the bus coupler
Current consumption160 mA contactor sealed; 160 mA contactor closing
Power dissipation in W3.5 W at Ie AC-3
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width12.500 cm
Package 1 Length13.000 cm
Package 1 Weight711.000 g
Unit Type of Package 2S02
Number of Units in Package 214
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight10.252 kg
TeSys island - load management system up to 80A. Direct starter, 9 A, 4 kW for standard applications. Connection screw terminals, status LED. Device width 45 mm, for DIN rail mounting. 3-pole load output. Optimized for single-phase to three-phase loads, no control wiring required. Rated voltage 400 V, according to AC-3. TeSys island - Industry 4.0 optimized load management system with IIOT protocols. Load output card for measuring relevant values. Functions switching, overload protection, monitoring.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1780043
qrcode für Schneider Electric TPRST009 direct starter 9A