Schneider Electric TPRSS038, EAN: 3606489832810

Schneider Electric TPRSS038 direct starter 38A

Industrial Material > Automation > Industrial bus systems

Schneider Electric TPRSS038 direct starter 38A

Lieske Part No. 1780062
Mfg Part No TPRSS038
EAN-Code 3606489832810
Manufacturer Schneider Electric
Here only 230,13 EUR
273,85 EUR incl. VAT

Further information for Schneider Electric TPRSS038 direct starter 38A

Complementary
Mechanical durability30 Mcycles
Electrical durability1.4 Mcycles 38 A AC-3 at Ue 440 V; 2 Mcycles 40 A AC-1 at Ue 440 V
Maximum operating rate3600 cyc/mn AC-3
Operating time< 100 ms closing; < 30 ms opening
Safety functionSafe stop: category 0 conforming to IEC 60204-1 when associated with a TPRSM module; Safe stop: category 1 conforming to IEC 60204-1 when associated with a TPRSM module
Safety integrity levelSIL 2 conforming to IEC 61508 in single channel system architecture; SILCL 2 conforming to IEC 62061 in single channel system architecture; PL = d category 2 conforming to ISO 13849-1 in single channel system architecture
Safety performance levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Protection typeThermal overload protection; Motor overheat; Overcurrent; Undercurrent; Jam; Long start; Stall; Rapid cycle lockout; Rapid restart lockout; Phase sequence; Phase reversal; Phase loss; Phase unbalance; Ground current
Monitoring typeTime device ON; Time device switch ON; Number of faults; Number of switching cycles; Number of device power cycles; Average current Iavg; Average voltage Vavg; Max current Imax; Max voltage Vmax; Active and reactive power with voltage module; Active and reactive energy with voltage module; True power factor with voltage module
Local signalling1 LED (green/red) for DS (device status); 1 LED (green/red) for LS (load status)
StandardsEN/IEC 60947-1; EN/IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1
Product certificationsCSA; EAC; UL; CCC
Mounting modeHorizontal and vertical (35 mm symmetrical DIN rail)
Connections - terminalsScrew-clamp terminals 1 cable(s) 1.5…10 mm² (16 AWG...8 AWG) rigid; Screw-clamp terminals 2 cable(s) 1.5…10 mm² (16 AWG...8 AWG) rigid; Screw-clamp terminals 1 cable(s) 2.5…10 mm² (14 AWG...8 AWG) flexible without cable end; Screw-clamp terminals 2 cable(s) 2.5…10 mm² (14 AWG...8 AWG) flexible without cable end; Screw-clamp terminals 1 cable(s) 1.5…10 mm² (16 AWG...10 AWG) flexible with cable end; Screw-clamp terminals 2 cable(s) 1.5…6 mm² (16 AWG...10 AWG) flexible with cable end
Tightening torque2.5 N.m - with screwdriver flat Ø 6 mm; 2.5 N.m - with screwdriver Philips No 3
Width45 mm
Height121 mm
Depth115 mm
Net weight0.718 kg
Contractual warranty
Warranty (in months)18
Environment
Ambient air temperature for storage-25…70 °C
Ambient air temperature for operation-10…50 °C without derating; 50…60 °C with current derating
Relative humidity5…95 %
Operating altitude0...2000 m without derating
IP degree of protectionIP20
Pollution degree2
Protective treatmentTC
Fire resistance960 °C conforming to UL 94; 850 °C conforming to IEC 60695-2-1; 650 °C conforming to IEC 60695-2-12
Shock resistance15 gn (duration = 11 ms) conforming to IEC 60068-2-27
Vibration resistance1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Logistical informations
Country of originFR
Main
RangeTeSys
Product nameTeSys island
Device short nameTPRSS
Product or component typeSIL motor starter
Motor starter typeDirect on line
Device presentationDirect starter connected to an automation controller through a bus coupler; Operational only when connected to a bus coupler
Function availableUpstream voltage presence detection; Electrical line and load protection; Power and energy monitoring when connected with TPRVM voltage module; Safe stop function available when connected with a TPRSM module
Product compatibilityTPRBC bus coupler; TPRVM voltage interface module; TPRSM SIL interface module
Poles description3P (3 NO)
Utilisation categoryAC-1; AC-2; AC-3; AC-4; AC-3e
Motor power kW9 kW at 230 V 50 Hz (AC-3); 18.5 kW at 380...415 V 50 Hz (AC-3); 18.5 kW at 440 V 50 Hz (AC-3); 18.5 kW at 500 V 50 Hz (AC-3); 18.5 kW at 690 V 50 Hz (AC-3)
motor power HP (UL / CSA)2 hp at 120 V AC 60 Hz for 1 phase motors; 5 hp at 240 V AC 60 Hz for 1 phase motors; 10 hp at 208 V AC 60 Hz for 3 phases motors; 10 hp at 240 V AC 60 Hz for 3 phases motors; 20 hp at 480 V AC 60 Hz for 3 phases motors; 25 hp at 600 V AC 60 Hz for 3 phases motors
[Ie] rated operational current38 A (at
[Ith] conventional free air thermal current40 A (at 50 °C)
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
Overvoltage categoryIII for Ue
Thermal protection adjustment range0.76…38 A
Thermal overload classClass 5…30
ResetRemotely or automatically
Irms rated making capacity550 A at 440 V conforming to IEC 60947
Rated breaking capacity550 A at 440 V conforming to IEC 60947
[Icw] rated short-time withstand current430 A 40 °C - 1 s; 310 A 40 °C - 10 s; 150 A 40 °C - 1 min; 60 A 40 °C - 10 min
Average impedance2 mOhm - Ith 40 A 50 Hz
Power dissipation per pole2.9 W AC-3 - Ith 38 A; 3.2 W AC-1 - Ith 40 A
[Uc] control circuit voltage24 V DC supplied by the bus coupler
Current consumption160 mA contactor sealed; 160 mA contactor closing
Power dissipation in W11.8 W at Ie AC-3
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.5 cm
Package 1 Width12.5 cm
Package 1 Length13 cm
Package 1 Weight772 g
Unit Type of Package 2S02
Number of Units in Package 214
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight11.109 kg
TeSys island - load management system up to 80A. Direct starter, 38 A, 18.5 kW for safety applications. Connection screw terminals, status LED. Device width 45 mm, for DIN rail mounting. 3-pole load output can be used in combination up to Ple. Optimized for single-phase to three-phase loads, no control wiring required. Rated voltage 400 V, according to AC-3. TeSys island - Industry 4.0 optimized load management system with IIOT protocols. Load output card for measuring relevant values. Functions switching, overload protection, monitoring.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1780062
qrcode für Schneider Electric TPRSS038 direct starter 38A