| Complementary |
| Mechanical durability | 30 Mcycles |
| Electrical durability | 1.65 Mcycles 25 A AC-3 at Ue 440 V; 2 Mcycles 30 A AC-1 at Ue 440 V |
| Maximum operating rate | 3600 cyc/mn AC-3 |
| Operating time | < 100 ms closing; < 30 ms opening |
| Safety function | Safe stop: category 0 conforming to IEC 60204-1 when associated with a TPRSM module; Safe stop: category 1 conforming to IEC 60204-1 when associated with a TPRSM module |
| Safety integrity level | SIL 2 conforming to IEC 61508 in single channel system architecture; SILCL 2 conforming to IEC 62061 in single channel system architecture; PL = d category 2 conforming to ISO 13849-1 in single channel system architecture |
| Safety performance level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Protection type | Thermal overload protection; Motor overheat; Overcurrent; Undercurrent; Jam; Long start; Stall; Rapid cycle lockout; Phase sequence; Rapid restart lockout; Phase reversal; Phase loss; Phase unbalance; Ground current |
| Monitoring type | Time device ON; Time device switch ON; Number of faults; Number of switching cycles; Number of device power cycles; Average current Iavg; Average voltage Vavg; Max current Imax; Max voltage Vmax; Active and reactive power with voltage module; Active and reactive energy with voltage module; True power factor with voltage module |
| Local signalling | 1 LED (green/red) for DS (device status); 1 LED (green/red) for LS (load status) |
| Standards | EN/IEC 60947-1; EN/IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1 |
| Product certifications | CCC; EAC; UL; CSA |
| Mounting mode | Horizontal and vertical (35 mm symmetrical DIN rail) |
| Connections - terminals | Screw-clamp terminals 1 cable(s) 1.5…10 mm² (16 AWG...8 AWG) rigid; Screw-clamp terminals 2 cable(s) 1.5…10 mm² (16 AWG...8 AWG) rigid; Screw-clamp terminals 1 cable(s) 2.5…10 mm² (14 AWG...8 AWG) flexible without cable end; Screw-clamp terminals 2 cable(s) 2.5…10 mm² (14 AWG...8 AWG) flexible without cable end; Screw-clamp terminals 1 cable(s) 1.5…10 mm² (16 AWG...10 AWG) flexible with cable end; Screw-clamp terminals 2 cable(s) 1.5…6 mm² (16 AWG...10 AWG) flexible with cable end |
| Tightening torque | 2.5 N.m - with screwdriver flat Ø 6 mm; 2.5 N.m - with screwdriver Philips No 3 |
| Width | 45 mm |
| Height | 121 mm |
| Depth | 115 mm |
| Net weight | 0.718 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Ambient air temperature for storage | -25…70 °C |
| Ambient air temperature for operation | -10…50 °C without derating; 50…60 °C with current derating |
| Relative humidity | 5…95 % |
| Operating altitude | 0...2000 m without derating |
| IP degree of protection | IP20 |
| Pollution degree | 2 |
| Protective treatment | TC |
| Fire resistance | 960 °C conforming to UL 94; 850 °C conforming to IEC 60695-2-1; 650 °C conforming to IEC 60695-2-12 |
| Shock resistance | 15 gn (duration = 11 ms) conforming to IEC 60068-2-27 |
| Vibration resistance | 1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys |
| Product name | TeSys island |
| Device short name | TPRSS |
| Product or component type | SIL motor starter |
| Motor starter type | Direct on line |
| Device presentation | Direct starter connected to an automation controller through a bus coupler; Operational only when connected to a bus coupler |
| Function available | Upstream voltage presence detection; Electrical line and load protection; Power and energy monitoring when connected with TPRVM voltage module; Safe stop function available when connected with a TPRSM module |
| Product compatibility | TPRBC bus coupler; TPRVM voltage interface module; TPRSM SIL interface module |
| Poles description | 3P (3 NO) |
| Utilisation category | AC-1; AC-2; AC-3; AC-4; AC-3e |
| Motor power kW | 5.5 kW at 230 V 50 Hz (AC-3); 11 kW at 380...415 V 50 Hz (AC-3); 11 kW at 440 V 50 Hz (AC-3); 15 kW at 500 V 50 Hz (AC-3); 15 kW at 690 V 50 Hz (AC-3) |
| motor power HP (UL / CSA) | 2 hp at 120 V AC 60 Hz for 1 phase motors; 3 hp at 240 V AC 60 Hz for 1 phase motors; 7.5 hp at 208 V AC 60 Hz for 3 phases motors; 7.5 hp at 240 V AC 60 Hz for 3 phases motors; 15 hp at 480 V AC 60 Hz for 3 phases motors; 20 hp at 600 V AC 60 Hz for 3 phases motors |
| [Ie] rated operational current | 25 A (at |
| [Ith] conventional free air thermal current | 30 A (at 50 °C) |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
| Overvoltage category | III for Ue |
| Thermal protection adjustment range | 0.5…25 A |
| Thermal overload class | Class 5…30 |
| Reset | Remotely or automatically |
| Irms rated making capacity | 450 A at 440 V conforming to IEC 60947 |
| Rated breaking capacity | 450 A at 440 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 380 A 40 °C - 1 s; 240 A 40 °C - 10 s; 120 A 40 °C - 1 min; 50 A 40 °C - 10 min |
| Average impedance | 2 mOhm - Ith 30 A 50 Hz |
| Power dissipation per pole | 1.25 W AC-3 - Ith 25 A; 1.8 W AC-1 - Ith 30 A |
| [Uc] control circuit voltage | 24 V DC supplied by the bus coupler |
| Current consumption | 160 mA contactor sealed; 160 mA contactor closing |
| Power dissipation in W | 6.6 W at Ie AC-3 |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.0 cm |
| Package 1 Width | 12.5 cm |
| Package 1 Length | 13.0 cm |
| Package 1 Weight | 772.0 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 14 |
| Package 2 Height | 15.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 11.104 kg |
TeSys island - load management system up to 80A. Direct starter, 25 A, 11 kW for safety applications. Connection screw terminals, status LED. Device width 45 mm, for DIN rail mounting. 3-pole load output can be used in combination up to Ple. Optimized for single-phase to three-phase loads, no control wiring required. Rated voltage 400 V, according to AC-3. TeSys island - Industry 4.0 optimized load management system with IIOT protocols. Load output card for measuring relevant values. Functions switching, overload protection, monitoring.