Schneider Electric TM241CE24R, EAN: 3606480648830

Schneider Electric TM241CE24R PLC controller 24E/A relay Ethernet

Industrial Material > Automation > PLC Systems

Schneider Electric TM241CE24R PLC controller 24E/A relay Ethernet

Lieske Part No. 934767
Mfg Part No TM241CE24R
EAN-Code 3606480648830
Manufacturer Schneider Electric
Here only 362,71 EUR
431,62 EUR incl. VAT

Further information for Schneider Electric TM241CE24R PLC controller 24E/A relay Ethernet

Complementary
Discrete I/O number24
Maximum number of I/O expansion module7 (local I/O-Architecture); 14 (remote I/O-Architecture)
Supply voltage limits85…264 V
Network frequency50/60 Hz
Discrete input logicSink or source
Discrete input voltage24 V
Discrete input voltage typeDC
Voltage state 1 guaranteed>= 15 V for input
Discrete input current5 mA for input
Input impedance4.7 kOhm for input
Response time50 µs turn-on, I0...I13 terminal(s) for input
Configurable filtering time1 s for fast input
Discrete output logicPositive logic (source)
Output voltage limits125 V DC relay output; 30 V DC transistor output; 277 V AC relay output
Maximum output frequency1 kHz for transistor output; 20 kHz for fast output (PWM mode); 100 kHz for fast output (PLS mode)
Accuracy+/- 0.1 % at 0.02…0.1 kHz for fast output; +/- 1 % at 0.1…1 kHz for fast output
Protection typeShort-circuit protection for transistor output; Short-circuit and overload protection with automatic reset for transistor output; Reverse polarity protection for transistor output; Without protection for relay output
Reset time10 ms automatic reset output; 12 s automatic reset fast output
Memory capacity64 MB for system memory RAM
Data backed up128 MB built-in flash memory for backup of user programs
Battery typeBR2032 lithium non-rechargeable, battery life: 4 year(s)
Backup time2 years at 25 °C
Execution time for 1 KInstruction0.3 ms for event and periodic task; 0.7 ms for other instruction
Application structure8 external event tasks; 3 cyclic master tasks + 1 freewheeling task; 8 event tasks; 4 cyclic master tasks
Realtime clockWith
Positioning functionsPTO function 4 channel(s) (positioning frequency: 100 kHz)
Counting input number4 fast input (HSC mode) at 200 kHz; 14 standard input at 1 kHz
Control signal typeA/B at 100 kHz for fast input (HSC mode); Pulse/direction at 200 kHz for fast input (HSC mode); Single phase at 200 kHz for fast input (HSC mode)
Integrated connection typeNon isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface ; Non isolated serial link serial 2 with removable screw terminal block connector and RS485 interface ; USB port with mini B USB 2.0 connector; Ethernet with RJ45 connector
Supply(serial 1)serial link supply: 5 V
Transmission rate1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485; 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232; 480 Mbit/s for bus length of 3 m for USB; 10/100 Mbit/s for Ethernet
Communication port protocolNon isolated serial link: Modbus master/slave
Port Ethernet10BASE-T/100BASE-TX - 1 port(s) copper cable
Local signalling1 LED (green) for PWR; 1 LED (green) for RUN; 1 LED (red) for module error (ERR); 1 LED (red) for I/O error (I/O); 1 LED (green) for SD card access (SD); 1 LED (red) for BAT; 1 LED (green) for SL1; 1 LED (green) for SL2; 1 LED (red) for bus fault on TM4 (TM4); 1 LED per channel (green) for I/O state; 1 LED (green) for Ethernet port activity
Electrical connectionremovable screw terminal blockfor inputs and outputs (pitch 5.08 mm); removable screw terminal blockfor connecting the 24 V DC power supply (pitch 5.08 mm)
Maximum cable distance between devicesUnshielded cable:
InsulationBetween supply and internal logic at 500 V AC; Non-insulated between supply and ground
MarkingCE
Sensor power supply24 V DC at 400 mA supplied by the controller
Surge withstand2 kV power lines (AC) common mode conforming to IEC 61000-4-5; 2 kV relay output common mode conforming to IEC 61000-4-5; 1 kV shielded cable common mode conforming to IEC 61000-4-5; 1 kV power lines (AC) differential mode conforming to IEC 61000-4-5; 1 kV relay output differential mode conforming to IEC 61000-4-5; 1 kV input common mode conforming to IEC 61000-4-5; 1 kV transistor output common mode conforming to IEC 61000-4-5
Web servicesWeb server
Maximum number of connections8 Modbus server; 8 SoMachine protocol; 10 web server; 4 FTP server; 16 Ethernet/IP target; 8 Modbus client
Number of server device(s)64 Modbus TCP: ; 16 EtherNet/IP:
Cycle time10 ms 16 EtherNet/IP; 64 ms 64 Modbus TCP
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 rail conforming to IEC 60715; plate or panel with fixing kit
Height90 mm
Depth95 mm
Width150 mm
Net weight0.53 kg
Contractual warranty
Warranty (in months)18
Environment
StandardsANSI/ISA 12-12-01; CSA C22.2 No 142; CSA C22.2 No 213; IEC 61131-2:2007; Marine specification (LR, ABS, DNV, GL); UL 508
Product certificationsRCM; cULus; CE; UKCA; DNV-GL; ABS; LR
Resistance to electrostatic discharge8 kV in air conforming to IEC 61000-4-2; 4 kV on contact conforming to IEC 61000-4-2
Resistance to electromagnetic fields10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3; 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3; 1 V/m 2 GHz...3 GHz conforming to IEC 61000-4-3
Resistance to fast transients2 kV (power lines) conforming to IEC 61000-4-4; 2 kV (relay output) conforming to IEC 61000-4-4; 1 kV (Ethernet line) conforming to IEC 61000-4-4; 1 kV (serial link) conforming to IEC 61000-4-4; 1 kV (input) conforming to IEC 61000-4-4; 1 kV (transistor output) conforming to IEC 61000-4-4
Resistance to conducted disturbances10 V 0.15...80 MHz conforming to IEC 61000-4-6; 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL); 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Immunity to microbreaks10 ms
Ambient air temperature for operation-10…50 °C (vertical installation); -10…55 °C (horizontal installation)
Ambient air temperature for storage-25…70 °C
Relative humidity10…95 %, without condensation (in operation); 10…95 %, without condensation (in storage)
IP degree of protectionIP20 with protective cover in place
Pollution degree2
Operating altitude0...2000 m
Storage altitude0…3000 m
Vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail; 3 gn at 8.4…150 Hz on symmetrical rail; 3.5 mm at 5…8.4 Hz on panel mounting; 3 gn at 8.4…150 Hz on panel mounting
Shock resistance15 gn for 11 ms
Logistical informations
Country of originID
Main
Range of productModicon M241
Product or component typeLogic controller
[Us] rated supply voltage100...240 V AC
Discrete input number14, discrete input 8 fast input conforming to IEC 61131-2 Type 1
Discrete output typeRelay; Transistor
Discrete output number6 relay; 4 transistor 4 fast output
Discrete output voltage5...125 V DC for relay output; 5...250 V AC for relay output; 24 V DC for transistor output
Discrete output current2 A for relay output (Q4...Q9); 0.1 A for fast output (PTO mode) (TR0...TR3); 0.5 A for transistor output (TR0...TR3)
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.208 cm
Package 1 Width13.04 cm
Package 1 Length18.656 cm
Package 1 Weight760.0 g
Unit Type of Package 2S03
Number of Units in Package 28
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight6.97 kg
Unit Type of Package 3P06
Number of Units in Package 364
Package 3 Height75.0 cm
Package 3 Width40.0 cm
Package 3 Length80.0 cm
Package 3 Weight66 kg
The PLC controller Modicon M241 from manufacturer Schneider Electric, type TM241CE24R, is a logic controller for automating compact, powerful, and networked industrial machines. It features a total of 24 integrated digital I/O, with 14 inputs (6 standard and 8 fast inputs at 200 kHz) and 10 outputs (6 relay and 4 transistor outputs). The fast inputs support the HSC mode (High-Speed Counter) with a maximum counting frequency of 200 kHz, making them suitable for precise position and speed measurements. The transistor outputs can be operated as fast outputs (PTO mode), with a maximum frequency of 100 kHz. The relay outputs are rated for voltages up to 125 V DC or 277 V AC and can each handle 2 A, while the transistor outputs deliver 0.5 A (standard) or 0.1 A (fast output). The inputs operate at 24 V DC with an input logic according to IEC 61131-2 Type 1, providing a guaranteed status-1 signal at 15 V and status-0 at 5 V. The input response time is 50 µs, and the filter time for fast inputs is configurable, starting at 1 µs.

Applications

The controller is designed for use in industrial applications, particularly in machine building, packaging technology, material handling, and other areas requiring a compact, powerful, and networked control system. The integrated positioning function with PTO (Pulse Train Output) enables control of up to 4 coordinated axes, with support for 2 axes including profiles such as trapezoidal or S-profile, and operating modes such as Pulse-Direction (P/D), CW/CCW, PWM, and FG. The maximum positioning frequency is 100 kHz. The controller is therefore suitable for applications with high dynamic and precision requirements.

Functions and Equipment in Detail

The controller features an integrated system memory of 64 MB RAM and a 128 MB flash memory for secure storage of user programs. The data retention period for stored data is 2 years at an ambient temperature of 25 °C. The execution time for a boolean instruction is 0.3 ms (for event and periodic tasks) or 0.7 ms (for other instructions). The application structure includes 8 external event tasks, 3 cyclic master tasks, and one free-running task. An integrated real-time clock is provided. The controller includes a slot for an SD card, which can be used for data exchange or programming. A USB-mini-B port enables programming and configuration. A Run/Stop switch and a QR code for direct access to technical documentation are also integrated.

Technology Explained Simply

The controller is powered by a supply voltage of 100 to 240 V AC, with supply voltage limits of 85 to 264 V. The network frequency is 50/60 Hz. The digital outputs are implemented as relay and transistor outputs, with transistor outputs featuring short-circuit and overload protection with automatic reset, as well as reverse polarity protection. Relay outputs have no protection. The reset time is 10 ms for outputs and 12 s for fast outputs. The controller supports integrated control for up to 4 coordinated axes. Positioning functions include PTO with a frequency of 100 kHz. The counting inputs support HSC mode with a frequency of 200 kHz.

Compatibility and Accessories

The controller is expandable with up to one plug-in module. Various modules are available for expansion, including plug-in modules for analog inputs (e.g. TMC4TI2, TMC4AI2) and outputs (TMC4AQ2), as well as special modules for crane and lifting applications (TMC4HOIS01). Local and decentralized I/O expansion is achieved via the Modicon TM3/TM5 I/O system. The maximum number of I/O expansion modules is 7 (local) or 14 (remote). The controller features a serial interface (Serial 1) with an RJ45 socket and RS232/RS485 interface, as well as a second serial interface (Serial 2) with a detachable screw terminal block and RS485 interface. The transmission speed is 1.2 to 115.2 kBit/s (default 115.2 kBit/s). The interfaces support Modbus ASCII/RTU in master/slave mode. Additionally, an Ethernet connection with an RJ45 socket is provided. Programming is done via the software EcoStruxure Machine Expert, which can be downloaded from the website www.se.com. PLC programming follows IEC 61131-3 in programming languages Structured Text (ST), Function Block Diagram (FBD/CFC), Instruction List (AWL), Ladder Diagram (KOP), or Sequential Function Chart (SFC) based on CODESYS V3.

Mounting and Installation

The controller is connected via detachable screw terminal blocks. Mounting is either on a 35 mm DIN rail or directly on a control panel. The operating ambient temperature ranges from -10 °C to +55 °C. The controller is intended for use in non-hazardous areas, with certification for Class I, Division 2, Groups A, B, C, and D. Installation, commissioning, maintenance, and repair must only be performed by qualified personnel. Before mounting or maintenance, the entire system must be disconnected from the power supply, and de-energization must be verified using a calibrated voltage tester. After maintenance, all covers, cables, and connections must be re-secured, and grounding must be checked before power is restored.

Advantages in Operation

The controller offers high flexibility through the combination of integrated I/O, expandable modules, and various interfaces. The integrated positioning function enables drive control without additional hardware. Support for Modbus and Ethernet simplifies networking with other devices and systems. Programming via EcoStruxure Machine Expert and support for IEC 61131-3 ensure standardized and portable software development. The integrated real-time clock and 128 MB flash memory enable reliable data storage and backup. Certification according to CE, cULus, CSA, EAC, LR, ABS, DNV-GL, ODVA, and Achilles ensures compliance with international safety and quality standards.

The controller is designed for industrial environments and meets requirements for reliability, performance, and networking. The combination of compact design, powerful functions, and open interfaces makes it a versatile solution for modern automation tasks.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/934767
qrcode für Schneider Electric TM241CE24R PLC controller 24E/A relay Ethernet