Schneider Electric TM221C24R, EAN: 3606480648717

Schneider Electric TM221C24R PLC controller 24 I/O relay

Industrial Material > Automation > PLC Systems

Schneider Electric TM221C24R PLC controller 24 I/O relay

Lieske Part No. 1768007
Mfg Part No TM221C24R
EAN-Code 3606480648717
Manufacturer Schneider Electric
Here only 263,44 EUR
313,49 EUR incl. VAT

Further information for Schneider Electric TM221C24R PLC controller 24 I/O relay

Complementary
Discrete I/O number24
Maximum number of I/O expansion module7 (local I/O-Architecture); 14 (remote I/O-Architecture)
Supply voltage limits85…264 V
Network frequency50/60 Hz
Inrush current40 A
Maximum power consumption in VA55 VA at 100...240 V with max number of I/O expansion module; 32 VA at 100...240 V without I/O expansion module
Power supply output current0.52 A 5 V for expansion bus; 0.16 A 24 V for expansion bus
Discrete input logicSink or source (positive/negative)
Discrete input voltage24 V
Discrete input voltage typeDC
Analogue input resolution10 bits
LSB value10 mV
Conversion time1 ms per channel + 1 controller cycle time for analogue input analog input
Permitted overload on inputs+/- 30 V DC for 5 min (maximum) for analog input; +/- 13 V DC (permanent) for analog input
Voltage state 1 guaranteed>= 15 V for input
Discrete input current7 mA for discrete input; 5 mA for fast input
Input impedance3.4 kOhm for discrete input; 100 kOhm for analog input; 4.9 kOhm for fast input
Response time35 µs turn-off, I2...I5 terminal(s) for input; 10 ms turn-on for output; 10 ms turn-off for output; 5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input; 35 µs turn-on, other terminals terminal(s) for input; 5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input; 100 µs turn-off, other terminals terminal(s) for input
Configurable filtering time0 ms for input; 3 ms for input; 12 ms for input
Output voltage limits125 V DC; 277 V AC
Maximum current per output common4 A at COM 2; 7 A at COM 0; 7 A at COM 1
Absolute accuracy error+/- 1 % of full scale for analog input
Switching frequency20 switching operations/minute with maximum load
Mechanical durability20000000 cycles for relay output
Minimum load1 mA at 5 V DC for relay output
Protection typeWithout protection at 5 A
Reset time1 s
Memory capacity256 kB for user application and data RAM with 10000 instructions; 256 kB for internal variables RAM
Data backed up256 kB built-in flash memory for backup of application and data
Data storage equipment2 GB SD card (optional)
Battery typeBR2032 or CR2032X lithium non-rechargeable
Backup time1 year at 25 °C (by interruption of power supply)
Execution time for 1 KInstruction0.3 ms for event and periodic task
Execution time per instruction0.2 µs Boolean
Exct time for event task60 µs response time
Maximum size of object areas255 %C counters; 8000 %MW memory words; 512 %M memory bits; 512 %KW constant words; 255 %TM timers
Realtime clockWith
Regulation loopAdjustable PID regulator up to 14 simultaneous loops
Counting input number4 fast input (HSC mode) at 100 kHz 32 bits
counter functionA/B; Single phase; Pulse/direction
Integrated connection typeUSB port with mini B USB 2.0 connector; Non isolated serial link serial 1 with RJ45 connector and RS485 interface ; Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface
Supply(serial)serial link supply: 5 V
Transmission rate1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485; 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232; 480 Mbit/s for USB
Communication port protocolUSB port: USB - SoMachine-Network; Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
Local signalling1 LED (green) for PWR; 1 LED (green) for RUN; 1 LED (red) for module error (ERR); 1 LED (green) for SD card access (SD); 1 LED (red) for BAT; 1 LED (green) for SL1; 1 LED (green) for SL2; 1 LED per channel (green) for I/O state
Electrical connectionremovable screw terminal block for inputs; removable screw terminal block for outputs; terminal block, 3 terminal(s) for connecting the 24 V DC power supply; connector, 4 terminal(s) for analogue inputs; Mini B USB 2.0 connector for a programming terminal
Maximum cable distance between devicesShielded cable:
MarkingCE
Sensor power supply24 V DC at 250 mA supplied by the controller
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 rail conforming to IEC 60715; plate or panel with fixing kit
Height90 mm
Depth70 mm
Width110 mm
Net weight0.395 kg
Contractual warranty
Warranty (in months)18
Environment
StandardsIEC 61131-2; UL 508; CAN/CSA C22.2 No. 213; IACS E10; ANSI/ISA 12-12-01
Product certificationsLR; ABS; DNV-GL; RCM; cULus; EAC; CE; UKCA; cULus HazLoc
Environmental characteristicOrdinary and hazardous location
Resistance to electrostatic discharge8 kV in air conforming to IEC 61000-4-2; 4 kV on contact conforming to IEC 61000-4-2
Resistance to electromagnetic fields10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3; 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3; 1 V/m 2...2.7 GHz conforming to IEC 61000-4-3
Resistance to magnetic fields30 A/m 50/60 Hz conforming to IEC 61000-4-8
Resistance to fast transients2 kV (power lines) conforming to IEC 61000-4-4; 2 kV (relay output) conforming to IEC 61000-4-4; 1 kV (I/O) conforming to IEC 61000-4-4; 1 kV (Ethernet line) conforming to IEC 61000-4-4; 1 kV (serial link) conforming to IEC 61000-4-4
Resistance to conducted disturbances10 V 0.15...80 MHz conforming to IEC 61000-4-6; 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL); 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Immunity to microbreaks10 ms
Ambient air temperature for operation-10…55 °C (horizontal installation); -10…35 °C (vertical installation)
Ambient air temperature for storage-25…70 °C
Relative humidity10…95 %, without condensation (in operation); 10…95 %, without condensation (in storage)
IP degree of protectionIP20 with protective cover in place
Operating altitude0...2000 m
Storage altitude0…3000 m
Vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail; 3.5 mm at 5…8.4 Hz on panel mounting; 1 gn at 8.4…150 Hz on symmetrical rail; 1 gn at 8.4…150 Hz on panel mounting
Shock resistance98 m/s² for 11 ms
Logistical informations
Country of originTW
Main
Range of productModicon M221
Product or component typeLogic controller
[Us] rated supply voltage100...240 V AC
Discrete input number14, discrete input conforming to IEC 61131-2 Type 1
Analogue input number2 at 0...10 V
Discrete output typeRelay normally open
Discrete output number10 relay
Discrete output voltage5...125 V DC; 5...250 V AC
Discrete output current2 A
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height10.600 cm
Package 1 Width13.900 cm
Package 1 Length15.500 cm
Package 1 Weight645.000 g
Unit Type of Package 2S04
Number of Units in Package 220
Package 2 Height30.000 cm
Package 2 Width40.000 cm
Package 2 Length60.000 cm
Package 2 Weight12.900 kg
Unit Type of Package 3P12
Number of Units in Package 3240
Package 3 Height105.000 cm
Package 3 Width80.000 cm
Package 3 Length120.000 cm
Package 3 Weight164.000 kg
Modicon M221 PLC controller in compact format with 0.2µs / Boolean instruction for the automation of simple industrial machines. A total of 24 integrated I/Os, of which 14 are digital (10 standard with 5kHz and 4 HSC with 100kHz) inputs, 10 digital outputs. Additionally 2 analog (0V to 10V / 10Bit) inputs. An RS485/RS232 interface with RJ45 socket for Modbus ASCII/RTU Master/Slave, ASCII character string, Modbus Serial IO scanner. The power supply is via 100VAC to 240VAC. The digital outputs are designed as relays (2A). Can be expanded with up to one plug-in module. 640 kB integrated RAM memory and 2 MB flash memory. Integrated control for up to 2 coordinated axes. Position Control (PTO) with trapezoidal or S-profile for 2 axes in pulse direction (P/D) mode or one axis in CW/CCW mode. Equipped with a slot for SD card, a USB mini-B port for programming, a run/stop switch and QR code for direct access to technical documentation. Local and decentralized I/O expansion with Modicon TM3 I/O system. Programming and configuration using free EcoStruxure Machine Expert - Basic software (download from www.se.com). PLC programming according to IEC 61131-3 in the programming languages instruction list (IL), ladder diagram (LD) or sequential function chart (Grafcet list/SFC). Connection via removable screw terminal block. Ambient temperature during operation -15°C to +50°C. Mounting on 35mm DIN rail or directly on control panel. Certified to CE, cULus Listing Mark, CSA, RCM, EAC, LR, ABS, DNV-GL, cCSAus Hazardous Zone.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1768007
qrcode für Schneider Electric TM221C24R PLC controller 24 I/O relay