Schneider Electric SR3PACK2BD, EAN: 3389110550047

Schneider Electric SR3PACK2BD logic module 24 VDC

Industrial Material > Automation > Small PLCs

Schneider Electric SR3PACK2BD logic module 24 VDC

Lieske Part No. 584378
Mfg Part No SR3PACK2BD
EAN-Code 3389110550047
Manufacturer Schneider Electric
Here only 394,05 EUR
468,92 EUR incl. VAT

Further information for Schneider Electric SR3PACK2BD logic module 24 VDC

Complementary
Kit compositionCable PC SR2USB01 for connection to PC; SR3B261BD
Input/output number26
Local displayWith
Number or control scheme lines120 with ladder programming; 0…200 with FBD programming
Cycle time6…90 ms
Backup time10 years at 25 °C
Clock drift12 min/year at 0…55 °C; 6 s/month at 25 °C
ChecksProgram memory on each power up
[Us] rated supply voltage24 V
Supply voltage limits19.2…30 V
Maximum supply current190 mA (without extension); 300 mA (with extensions)
Power dissipation in W10 W with extensions; 6 W without extension
Reverse polarity protectionWith
Discrete input typeResistive
Discrete input voltage24 V DC
Discrete input current4 mA
Counting frequency1 kHz for discrete input
Voltage state 1 guaranteed>= 15 V for I1...IA and IH...IR discrete input circuit; >= 15 V for IB...IG used as discrete input circuit
Current state 1 guaranteed>= 1.2 mA (IB...IG used as discrete input circuit); >= 2.2 mA (I1...IA and IH...IR discrete input circuit)
Input compatibility3-wire proximity sensors PNP for discrete input
Analogue input number6
Analogue input typeCommon mode
Analogue input range0...10 V; 0...24 V
Temperature probe typeNTC 10k at 25 °C; NTC 1000k at 25 °C; KTY81 210/220/221/222/250; Pt 500
Maximum permissible voltage30 V for analogue input circuit
Analogue input resolution8 bits
LSB value39 mV for analogue input circuit
Conversion timeSmart relay cycle time for analogue input circuit
Conversion error+/- 5 % at 25 °C for analogue input circuit; +/- 6.2 % at 55 °C for analogue input circuit
Repeat accuracy+/- 2 % at 55 °C for analogue input circuit
Operating distance10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
Input impedance12 kOhm for IB...IG used as analogue input circuit; 12 kOhm for IB...IG used as discrete input circuit; 7.4 kOhm for I1...IA and IH...IR discrete input circuit
Output voltage limits24...250 V AC (relay output); 5...30 V DC (relay output)
Contacts type and compositionNO for relay output
Output thermal current5 A for 2 outputs for relay output; 8 A for 8 outputs for relay output
Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to IEC 60947-5-1; AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to IEC 60947-5-1; DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to IEC 60947-5-1; DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to IEC 60947-5-1
Switching capacity in mA>= 10 mA at 12 V (relay output)
Operating rate in Hz0.1 Hz (at Ie) for relay output; 10 Hz (no load) for relay output
Mechanical durability10000000 cycles for relay output
[Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
ClockWith
Response time10 ms (from state 0 to state 1) for relay output; 5 ms (from state 1 to state 0) for relay output
Connections - terminalsScrew terminals, 1 x 0.2...1 x 2.5 mm² (25 AWG...14 AWG) semi-solid; Screw terminals, 1 x 0.2...1 x 2.5 mm² (25 AWG...14 AWG) solid; Screw terminals, 1 x 0.25...1 x 2.5 mm² (24 AWG...14 AWG) flexible with cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) solid; Screw terminals, 2 x 0.25...2 x 0.75 mm² (24 AWG...18 AWG) flexible with cable end
Tightening torque0.5 N.m
Overvoltage categoryIII conforming to IEC 60664-1
Net weight0.85 kg
Contractual warranty
Warranty (in months)18
Environment
Immunity to microbreaks1 ms
Product certificationsGOST; GL; UL; CSA; C-Tick
StandardsIEC 61000-4-4 level 3; IEC 61000-4-12; IEC 60068-2-6 Fc; IEC 60068-2-27 Ea; IEC 61000-4-5; IEC 61000-4-6 level 3; IEC 61000-4-2 level 3; IEC 61000-4-3; IEC 61000-4-11
IP degree of protectionIP20 (terminal block) conforming to IEC 60529; IP40 (front panel) conforming to IEC 60529
Environmental characteristicEMC directive conforming to IEC 61000-6-2; EMC directive conforming to IEC 61000-6-3; EMC directive conforming to IEC 61000-6-4; EMC directive conforming to IEC 61131-2 zone B; Low voltage directive conforming to IEC 61131-2
Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
Pollution degree2 conforming to IEC 61131-2
Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2; -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
Ambient air temperature for storage-40…70 °C
Operating altitude2000 m
Maximum altitude transport3048 m
Relative humidity95 % without condensation or dripping water
Logistical informations
Country of originFR
Main
Range of productZelio Logic
Product or component typeModular discovery packs
Discrete input number16 conforming to IEC 61131-2 Type 1
Number of outputs10 relay
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.600 cm
Package 1 Width15.500 cm
Package 1 Length23.500 cm
Package 1 Weight531.000 g
Unit Type of Package 2S03
Number of Units in Package 210
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight5.803 kg
Starter kit for Zelio Logic in modular design (SR3). The set consists of 1x Zelio Logic (SR3B261BD) and 1x programming cable (SR2USB01).
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/584378
qrcode für Schneider Electric SR3PACK2BD logic module 24 VDC