Schneider Electric SR2PACKBD, EAN: 3389110549386

Schneider Electric SR2PACKBD logic module compact 24 VDC

Industrial Material > Automation > Small PLCs

Schneider Electric SR2PACKBD logic module compact 24 VDC

Lieske Part No. 232905
Mfg Part No SR2PACKBD
EAN-Code 3389110549386
Manufacturer Schneider Electric
Here only 263,04 EUR
313,02 EUR incl. VAT

Further information for Schneider Electric SR2PACKBD logic module compact 24 VDC

Complementary
Kit compositionSR2B121BD; Cable PC SR2USB01 for connection to PC
Input/output number12
Local displayWith
Number or control scheme lines120 with ladder programming; 0…200 with FBD programming
Cycle time6…90 ms
Backup time10 years at 25 °C
Clock drift12 min/year at 0…55 °C; 6 s/month at 25 °C
ChecksProgram memory on each power up
[Us] rated supply voltage24 V
Supply voltage limits19.2…30 V
Maximum supply current100 mA (without extension)
Power dissipation in W3 W without extension
Reverse polarity protectionWith
Discrete input typeResistive
Discrete input voltage24 V DC
Discrete input current4 mA
Counting frequency1 kHz for discrete input
Voltage state 1 guaranteed>= 15 V for I1...IA and IH...IR discrete input circuit; >= 15 V for IB...IG used as discrete input circuit
Current state 1 guaranteed>= 1.2 mA (IB...IG used as discrete input circuit); >= 2.2 mA (I1...IA and IH...IR discrete input circuit)
Input compatibility3-wire proximity sensors PNP for discrete input
Analogue input number4
Analogue input typeCommon mode
Analogue input range0...10 V; 0...24 V
Temperature probe typeNTC 10k at 25 °C; NTC 1000k at 25 °C; KTY81 210/220/221/222/250; Pt 500
Maximum permissible voltage30 V for analogue input circuit
Analogue input resolution8 bits
LSB value39 mV for analogue input circuit
Conversion timeSmart relay cycle time for analogue input circuit
Conversion error+/- 5 % at 25 °C for analogue input circuit; +/- 6.2 % at 55 °C for analogue input circuit
Repeat accuracy+/- 2 % at 55 °C for analogue input circuit
Operating distance10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
Input impedance12 kOhm for IB...IG used as analogue input circuit; 12 kOhm for IB...IG used as discrete input circuit; 7.4 kOhm for I1...IA and IH...IR discrete input circuit
Output voltage limits24...250 V AC (relay output); 5...30 V DC (relay output)
Contacts type and compositionNO for relay output
Output thermal current8 A for all 4 outputs for relay output
Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to IEC 60947-5-1; AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to IEC 60947-5-1; DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to IEC 60947-5-1; DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to IEC 60947-5-1
Switching capacity in mA>= 10 mA at 12 V (relay output)
Operating rate in Hz0.1 Hz (at Ie) for relay output; 10 Hz (no load) for relay output
Mechanical durability10000000 cycles for relay output
[Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
ClockWith
Response time10 ms (from state 0 to state 1) for relay output; 5 ms (from state 1 to state 0) for relay output
Connections - terminalsScrew terminals, 1 x 0.2...1 x 2.5 mm² (25 AWG...14 AWG) semi-solid; Screw terminals, 1 x 0.2...1 x 2.5 mm² (25 AWG...14 AWG) solid; Screw terminals, 1 x 0.25...1 x 2.5 mm² (24 AWG...14 AWG) flexible with cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) solid; Screw terminals, 2 x 0.25...2 x 0.75 mm² (24 AWG...18 AWG) flexible with cable end
Tightening torque0.5 N.m
Overvoltage categoryIII conforming to IEC 60664-1
Net weight0.7 kg
Contractual warranty
Warranty (in months)18
Environment
Immunity to microbreaks1 ms
Product certificationsCSA; C-Tick; UL; GOST; GL
StandardsIEC 61000-4-4 level 3; IEC 61000-4-12; IEC 61000-4-5; IEC 60068-2-6 Fc; IEC 61000-4-2 level 3; IEC 61000-4-6 level 3; IEC 61000-4-3; IEC 61000-4-11; IEC 60068-2-27 Ea
IP degree of protectionIP20 (terminal block) conforming to IEC 60529; IP40 (front panel) conforming to IEC 60529
Environmental characteristicEMC directive conforming to IEC 61000-6-2; EMC directive conforming to IEC 61000-6-3; EMC directive conforming to IEC 61000-6-4; EMC directive conforming to IEC 61131-2 zone B; Low voltage directive conforming to IEC 61131-2
Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
Pollution degree2 conforming to IEC 61131-2
Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2; -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
Ambient air temperature for storage-40…70 °C
Operating altitude2000 m
Maximum altitude transport3048 m
Relative humidity95 % without condensation or dripping water
Logistical informations
Country of originFR
Main
Range of productZelio Logic
Product or component typeCompact discovery packs
Discrete input number8 conforming to IEC 61131-2 Type 1
Number of outputs4 relay
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.500 cm
Package 1 Width15.500 cm
Package 1 Length23.500 cm
Package 1 Weight396.000 g
Unit Type of Package 2S03
Number of Units in Package 210
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight4.455 kg
Log Schneider Electric Zelio Logic Compact Modules - Starter Package - SR2PACKBD 12 I / O - 24 V DC
Composition of the kit:
SR2USB01 PC cable for connection to the PC
SR2B121BD logic module
Zelio Soft 2, CD-ROM with programming software Number of inputs / outputs; 12 Rated supply voltage Us 24 VD Type: SR2PACKBD item: 1 ST.