| Complementary |
| Format of the drive | Block |
| Network number of phases | Single phase |
| [Us] rated supply voltage | 100...120 V - 15...10 %; 200...230 V - 15...10 % |
| Supply voltage type | AC/DC |
| Network frequency limits | 50…60 Hz (- 15...10 %) |
| Communication interface | Pulse/direction, integrated |
| Function available | Rotation monitoring; Holding brake monitoring |
| Maximum motor phase current | 6.8 A |
| Nominal power | 280 W at 115 V; 420 W at 230 V |
| Short-circuit current | 0.5 kA |
| Associated fuse rating | 10 A at 115 V; 6 A at 230 V |
| Overvoltage category | III |
| Inrush current | 60 A |
| Maximum leakage current | 30 mA IEC 60990-3 |
| Voltage state 1 guaranteed | 15...30 V for 24 V optocoupler input signals; 2.5...5.25 V for 5 V optocoupler input signals |
| Input current | 25 mA for 5 V optocoupler input signals; 7 mA for 24 V optocoupler input signals |
| Maximum input frequency | 200 kHz for 24 V optocoupler input signals; 200 kHz for 5 V optocoupler input signals; 400 kHz for ENC_A/ENC_B signal input |
| Maximum switching voltage | 30 V DC (readiness signal output) |
| Maximum switching current | 200 mA (readiness signal output); 50 mA (24 V output signals)RM-FAULT_OUT; 1.7 mA (24 V output signals)+BRAKE_OUT |
| Physical interface | RS422 - ENC_A/ENC_B signal input |
| Input voltage | 24 V -15 %/+20 % for 24 V control voltage |
| Type of cooling | Fan |
| Maximum mechanical speed | 3000 rpm |
| Height | 145 mm |
| Width | 72 mm |
| Depth | 140 mm |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Net weight | 1.2 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Electromagnetic compatibility | Electrostatic discharge level 3 conforming to IEC 61000-4-2; Immunity to electrical transients level 4 conforming to IEC 61000-4-4; Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3; Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
| Standards | EN 61800-3; EN/IEC 61800-5-1 |
| Product certifications | UL; cUL |
| Marking | CE |
| Ambient air temperature for operation | 0…40 °C conforming to UL; 0…50 °C |
| Ambient air temperature for storage | -25…70 °C |
| Pollution degree | Level 2 |
| Relative humidity | 5…85 % without condensation |
| Operating altitude | 1000...< 2000 m without derating (maximum ambient temperature 40°C, no protective film, lateral distance of > 50mm) |
| Vibration resistance | 1 gn (f= 13…150 Hz) conforming to IEC 60068-2-6; 1.5 mm (f= 3…13 Hz) conforming to IEC 60068-2-6 |
| IP degree of protection | IP20; On upper part: IP40 (without removal of protective film) |
| Logistical informations |
| Country of origin | DE |
| Main |
| Range of product | Lexium SD3 |
| Product or component type | Motion stepper drive |
| Device short name | SD326 |
| Supply voltage limits | 100…120 V; 200…240 V |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 18 cm |
| Package 1 Width | 19.5 cm |
| Package 1 Length | 19 cm |
| Package 1 Weight | 1.325 kg |
| Unit Type of Package 2 | S04 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30 cm |
| Package 2 Width | 40 cm |
| Package 2 Length | 60 cm |
| Package 2 Weight | 9.202 kg |
Stepper motor amplifier from the Lexium SD326 series. The SD326 is a universally applicable stepper motor amplifier. In combination with selected 3-phase stepper motors, a very compact and powerful drive system is created. Setpoints are typically specified and monitored by a higher-level PLC or motion controller. This amplifier has a pulse/direction interface with speed monitoring and holding brake control. The peak current is up to 6.8 A. The supply voltage can be switched between 115/230 VAC and an EMC filter is integrated.