| Complementary |
| Network number of phases | Single phase |
| [Us] rated supply voltage | 24...48 V |
| Supply voltage type | DC |
| Supply voltage limits | 12…48 V |
| Maximum motor phase current | 5 A |
| Voltage state 0 guaranteed | 0...0.8 V for general purpose I/O defined as inputs |
| Voltage state 1 guaranteed | 2.2...24 V |
| Input current | 1.75 mA - high level for general purpose I/O defined as inputs |
| Output current | 600 mA - single channel, duty cycle = 0.8 for general purpose I/O defined as outputs; 275 mA - four channels, continuous for general purpose I/O defined as outputs |
| Input voltage | 0...24 V for general purpose I/O defined as inputs; 0...24 V for general purpose I/O defined as outputs |
| Residual ripple | 2 V at nominal voltage |
| Electrical connection | 1 connector wire crimp 4 pins for motor interface; 1 connector wire crimp 2 pins for supply voltage; 1 connector wire crimp 14 pins for multifunction interface; 1 connector wire crimp 10 pins for communication interface |
| Transmission rate | 4.8, 9.6, 19.2, 38.4, 115 kbauds |
| Type of cooling | Convection |
| Width | 76 mm |
| Height | 54 mm |
| Depth | 99 mm |
| Marking | CE |
| Net weight | 0.34 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Electromagnetic compatibility | Electrostatic discharge conforming to IEC 61000-4-2; Immunity to radiated radio-electrical interference conforming to IEC 61000-4-3; Immunity to electrical transients conforming to IEC 61000-4-4; Voltage/current impulse conforming to IEC 61000-4-5; Immunity to voltage dips conforming to IEC 61000-4-11; Immunity to conducted RF disturbances conforming to IEC 61000-4-6 |
| Standards | EN 55011 group 1 class A; EN 61000-3-3; IEC 61000-3-2 |
| Ambient air temperature for operation | 0…50 °C without derating with flange motor mounted on a steel plate 300 x 300 x 10 mm; 50…65 °C with power derating of 2.2 % per °C with flange motor mounted on a steel plate 300 x 300 x 10 mm |
| Ambient air temperature for storage | -25…70 °C |
| Relative humidity | 15…85 % without condensation |
| IP degree of protection | IP20 |
| Main |
| Range of product | Lexium SD2 |
| Product or component type | Motion stepper drive |
| Device short name | SD218 |
| Communication interface | RS485 |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 9.0 cm |
| Package 1 Width | 13.4 cm |
| Package 1 Length | 19.7 cm |
| Package 1 Weight | 519.0 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 8 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 4.865 kg |
Lexium SD2 Motion Control Schrittmotorverstärker Zur Ansteuerung der zweiphasigen BRS2-Schrittmotoren stehen die SD2-Schrittmotorverstärker zur Verfügung. Das hohe Drehmoment sowie niedrige Drehzahl des Verstärkers ermöglichen insbesondere Anwendungen im Bereich der Kurzstreckenpositionierungen. Das hohe Haltemoment im Stillstand reduziert ferner die Implementierungskosten bei Pick-and-Place-Anwendungen. Dieser Schrittmotorverstärker verfügt über eine Ansteuerung mittels serieller RS485-Schnittstelle und einen Spitzenausgangsstrom von 5 A. Die Versorgungsspannung beträgt 24-48 VDC.