| Complementary |
| [Us] rated supply voltage | self-powered |
| Supply voltage limits | 114…329 V AC |
| Power consumption in VA | 0…3.9 VA AC |
| Measurement range | 120...277 V AC |
| Voltage detection threshold | 114 V |
| Maximum measuring cycle | 150 ms measurement cycle as true rms value |
| Threshold adjustment voltage | 2...20 % of Un selected |
| Hysteresis | 2 % |
| Repeat accuracy | +/- 0.5 % for input and measurement circuit; +/- 1 % for time delay |
| Measurement error | < 1 % over the whole range with voltage variation; 0.05 %/°C with temperature variation |
| Time delay type | Adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault |
| Setting accuracy of time delay | 10 % |
| Reset time | 1500 ms time delay |
| Response time | < 200 ms (in the event of a fault) |
| Power on delay | 650 ms |
| Output contacts | 1 C/O + 1 C/O, 1 per threshold |
| nominal output current | 5 A |
| Maximum switching voltage | 250 V AC/DC |
| Switching capacity in VA | 1250 VA |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 5 A AC/DC |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Control circuit frequency | 50...60 Hz +/- 15 % |
| Measurement accuracy | +/- 10 % of the full scale value |
| Quality labels | CE |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4; Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3; Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
| Standards | IEC 60255-1 |
| Product certifications | UL; C-Tick; GL; CSA; GOST |
| Directives | 73/23/EEC - low voltage directive; 89/336/EEC - electromagnetic compatibility |
| Ambient air temperature for storage | -40…70 °C; -40…70 °C |
| Ambient air temperature for operation | -20…50 °C |
| Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529; IP30 (casing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Overvoltage category | III conforming to IEC 60664-1 |
| Dielectric test voltage | 2 kV, 1 min AC 50 Hz |
| Insulation resistance | > 500 MOhm at 500 V DC conforming to IEC 60255-5 |
| [Ui] rated insulation voltage | 400 V conforming to IEC 60664-1 |
| Operating position | Any position without derating |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (20 AWG...11 AWG) solid without cable end; Screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end; Screw terminals, 1 x 0.2...2 x 2.5 mm² (24 AWG...12 AWG) flexible with cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Polycarbonate |
| Local signalling | LED (green) for power ON; LED (yellow) for relay ON |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Reliability data | B10d = 470000; MTTFd = 502.2 years |
| Height | 90 mm; 88.9 mm |
| Width | 35 mm; 35.6 mm |
| Depth | 72 mm; 71.1 mm |
| Net weight | 0.13 kg; 0.13 kg |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range of product | Harmony Control Relays |
| Relay type | Voltage control relay |
| Product or component type | 3-phase control relay |
| Relay name | RM35UB3 |
| Relay monitored parameters | Absence of neutral; Overvoltage and undervoltage between phases; Overvoltage and undervoltage between neutral |
| Control type | Without test button |
| Contacts type and composition | 2 C/O |
| Product specific application | For 3-phase supply |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.700 cm |
| Package 1 Width | 7.800 cm |
| Package 1 Length | 9.700 cm |
| Package 1 Weight | 123.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.529 kg |
Harmony Control. This voltage monitoring relay monitors three-phase supplies for phase failure, as well as the mains voltage for exceeding or falling below an adjustable limit. The neutral conductor is also monitored. The voltage range between phase and neutral conductor is 120-277 VAC. Two relay changeover switches are available for reporting, which can handle up to 5 A. One relay is available for each over- and under-limit reporting. In the event of a phase failure, both relays switch. The two limit values and a switch-off delay are adjustable. The settings are made using controls on the front, which can be protected against changes under a transparent cover. Two LEDs show the status. The device is powered by the measuring voltage. The width is 17.5 mm and it is mounted on a top-hat rail.