| Complementary |
| [Us] rated supply voltage | 220...240 V AC/DC 50/60 Hz, self-powered |
| Supply voltage limits | 198…264 V AC |
| Maximum power consumption in VA | 12 VA AC |
| Measurement range | 0.5...10 A current AC 50/60 Hz |
| Maximum measuring cycle | 100 ms measurement cycle as true rms value |
| Hysteresis | 5…50 % adjustable of threshold setting; 3 % fixed of full scale for window mode |
| Setting accuracy of the switching threshold | +/- 10 % of the full scale |
| Repeat accuracy | +/- 0.5 % for input and measurement circuit; +/- 2 % for time delay |
| Measurement error | < 1 % over the whole range with voltage variation; 0.5 %/°C with temperature variation |
| Time delay type | Adjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault |
| Reset time | 1500 ms time delay |
| Power on Delay | 500 ms |
| Output contacts | 1 C/O |
| nominal output current | 5 A |
| Maximum switching voltage | 250 V AC |
| Switching capacity in VA | 1250 VA |
| Minimum switching current | 10 mA at 12 V AC |
| Maximum switching current | 5 A AC/DC |
| Electrical durability | 100000 cycles |
| Mechanical durability | 10000000 cycles |
| operating voltage tolerance | - 10 % + 10 % Un |
| Control circuit frequency | 50...60 Hz +/- 5 % |
| Resistance across terminals | 0.005 Ohm at L - Li |
| Measurement accuracy | +/- 10 % of the full scale value |
| Threshold setting | 10...100 % |
| Insulation | Between supply and measurement |
| Tightening torque | 5.3...8.8 lb.in; 0.6...1 N.m |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4; Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3; Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
| Standards | EN/IEC 60255-1; UL 508 |
| Product certifications | DNV-GL; cULus; UKCA; RCM; CE; CCC |
| Marking | ROHS; WEEE; China RoHS |
| Ambient air temperature for storage | -40…70 °C; -40…70 °C |
| Ambient air temperature for operation | -20…60 °C |
| Relative humidity | 93…97 % at 25…55 °C conforming to IEC 60068-2-30 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529; IP30 (housing) conforming to IEC 60529; IP50 (front panel) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Overvoltage category | III conforming to IEC 60664-1 |
| Dielectric test voltage | 2 kV, 1 min AC 50 Hz conforming to IEC 60255-5 |
| Insulation resistance | > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5 |
| [Ui] rated insulation voltage | 250 V conforming to IEC 60664-1 |
| Operating position | Any position without derating |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 3.3 mm² (20 AWG...12 AWG) solid without cable end; Screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end; Screw terminals, 1 x 0.5...1 x 2.5 mm² (20 AWG...14 AWG) flexible with cable end; Screw terminals, 2 x 0.5...2 x 1.5 mm² (20 AWG...16 AWG) flexible with cable end |
| Housing material | Polycarbonate |
| Local signalling | LED (green) for power ON; LED (yellow) for relay ON |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Height | 90 mm; 88.9 mm |
| Width | 17.5 mm; 17.8 mm |
| Depth | 72 mm; 71.1 mm |
| Net weight | 0.08 kg; 0.08 kg |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range of product | Harmony Control Relays |
| Relay type | Current control relay |
| Product or component type | Current control relay |
| Relay name | RM17JA |
| Relay monitored parameters | Overcurrent or undercurrent in window mode; Overcurrent or undercurrent detection |
| Control type | Without test button |
| Contacts type and composition | 1 C/O |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.700 cm |
| Package 1 Width | 7.900 cm |
| Package 1 Length | 10.000 cm |
| Package 1 Weight | 84.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.352 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 1152 |
| Package 3 Height | 104.600 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 112.943 kg |
Die Stromwächter RM17JA der Baureihe Harmony Control ermöglicht eine einfache Stromüberwachung in 1-phasigen Netzen. Dieses modulare, multifunktionale 1-phasige Steuerrelais eignet sich ideal zur Überwachung elektrischer Werte in Industrie- und Gebäudeanwendungen. Dieser Stromwächter ist konzipiert für den Einsatz in einem Spannungsbereich von 220V bis 240V AC. Die flexible und einfache Montage und Installation erfolgt bequem auf einer Hutschiene. Zudem bietet es neben der präzisen Einstellmöglichkeit an der Vorderseite des Geräts eine versiegelbare Abdeckung. Dieses Relais dient zur Überwachung von Überstrom- und Unterstrombedingungen im Bereich von 0,5 bis 10 A. Aufgrund der Vielzahl von vorhandenen Produktstandards und Zertifizierungen geeignet für den internationalen Einsatz. Zudem können Sie detaillierte Informationen zu Materialinhalten, Umweltauswirkungen und Kreislaufwirtschaft erhalten, die Ihre Nachhaltigkeitsziele unterstützen.