| Complementary |
| Contacts type and composition | 1 C/O timed contact |
| Time delay type | Star-delta |
| Time delay range | 1...10 min; 6...60 s; 0.1...1 s; 1...10 h; 1...10 s; 6...60 min; 10...100 h |
| Control type | Rotary knob front panel |
| [Us] rated supply voltage | 24...240 V AC; 24 V DC |
| Voltage range | 0.85...1.1 Us |
| Supply frequency | 50...60 Hz +/- 5 % |
| Connections - terminals | Screw terminals, 2 x 1.5 mm² with cable end; Screw terminals, 2 x 2.5 mm² without cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Polycarbonate |
| Repeat accuracy | +/- 0.5 % conforming to IEC 61812-1 |
| Temperature drift | +/- 0.05 %/°C |
| Voltage drift | +/- 0.2 %/V |
| Setting accuracy of time delay | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 |
| Control signal pulse width | 30 ms; 100 ms under load |
| Insulation resistance | 100 MOhm at 500 V DC conforming to IEC 60664-1 |
| Recovery time | 120 ms on de-energisation |
| Immunity to microbreaks | 10 ms |
| Power consumption in VA | 50 VA at 240 V AC |
| Power consumption in W | 0.7 W at 24 V DC |
| breaking capacity | 2000 VA |
| Minimum switching current | 10 mA at 5 V |
| Maximum switching current | 8 mA |
| Maximum switching voltage | 250 V |
| Electrical durability | 100000 cycles for resistive load, 8 A at 250 V, AC |
| Mechanical durability | 10000000 cycles |
| Rated impulse withstand voltage | 5 kV for 1.2…50 µs conforming to IEC 60664-1; 5 kV conforming to IEC 61812-1 |
| Power on delay | 100 ms |
| Safety reliability data | MTTFd = 182.6 years; B10d = 170000 |
| Mounting position | Any position in relation to normal vertical mounting plane |
| Mounting support | 35 mm DIN rail conforming to IEC 60715 |
| Status LED | LED green (flashing) for timing in progress; LED green (steady) for power ON; LED yellow for relay energised |
| Function available | Q-Star-delta relay (2 NO outputs with same common)-1 C/O |
| Width | 22.5 mm |
| Net weight | 0.086 kg |
| Number of functions | 1 |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Dielectric strength | 2.5 kV for 1 mA/1 minute at 50 Hz conforming to IEC 61812-1 |
| Standards | IEC 61000-6-4; IEC 61000-6-2; IEC 61000-6-3; IEC 61000-6-1; IEC 61812-1 |
| Directives | 2006/95/EC - low voltage directive; 2004/108/EC - electromagnetic compatibility |
| Product certifications | CSA; EAC; RCM; CE; CCC; GL; cULus |
| Ambient air temperature for operation | -20…60 °C |
| Ambient air temperature for storage | -30…60 °C |
| IP degree of protection | IP40 housing: conforming to IEC 60529; IP20 terminal block: conforming to IEC 60529; IP40 front face: conforming to IEC 60529 |
| Vibration resistance | 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Relative humidity | 93 %, without condensation conforming to IEC 60068-2-30 |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range of product | Harmony Timer Relays |
| Discrete output type | Relay |
| Product or component type | Modular timing relay |
| Device short name | RE22 |
| nominal output current | 8 A |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.6 cm |
| Package 1 Width | 8.2 cm |
| Package 1 Length | 9.6 cm |
| Package 1 Weight | 98.0 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 40 |
| Package 2 Height | 15.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 4.309 kg |
The
modular time relay RE22R1QMU from the Harmony Time series by Schneider Electric is an electronic control device for automation applications in industrial and technical installations. It is specifically designed for controlling
star-delta starting circuits, where a motor is initially started in star operation and then switched to delta operation after a preset delay time. The device is mounted on a
35 mm DIN rail and occupies a width of 22.5 mm, making it suitable for use in compact enclosures. The supply voltage is 24 V DC or 24–240 V AC, with the operating voltage functioning stably within a tolerance range of 0.85 to 1.1 times the nominal voltage. The frequency of the supply voltage ranges between 50 and 60 Hz, with a tolerance of ±5 %. Power supply is via the network cable, with power consumption being 50 VA at 240 V AC and 0.7 W at 24 V DC. The operating temperature ranges from -20 °C to 60 °C, and the storage temperature from -30 °C to 60 °C. Relative humidity may reach 93 %, but condensation is not permitted.
Applications
This time relay is used in industrial installations where a time-controlled switch from star to delta operation is required, for example in controlling asynchronous motors. The function reduces starting current and protects the system from excessive mechanical and electrical stress. Typical applications include pump systems, fan controls, conveyor systems, and other drive systems where a smooth motor start is necessary. The
star-delta function enables controlled switching, with the time delay adjusted via a rotary knob on the front panel. Adjustment ranges include: 0.1 to 1 second, 1 to 10 seconds, 6 to 60 seconds, 1 to 10 minutes, 6 to 60 minutes, 1 to 10 hours, and 10 to 100 hours. Additionally, a range of 20 to 140 milliseconds is available for very short delays. Adjustment accuracy is ±10 % of the scale end value at 25 °C, repeatability is ±0.5 %, and temperature deviation is ±0.05 % per degree Celsius. Voltage drift is ±0.2 % per volt.
Functions and Features in Detail
The device features a
relay output with a changeover contact rated up to 8 A. The maximum switching voltage is 250 V, and the minimum switching current is 10 mA at 5 V. The electrical life under resistive load is 100,000 cycles at 8 A and 250 V AC, while the mechanical life is 10,000,000 cycles. The switching function is operated via a rotary knob on the front panel, protected under a transparent cover to prevent unintended changes. Operation is performed using a test button to verify functions. Status indication is provided by LEDs: a green LED blinks during timing, remains steadily lit when power is applied, and a yellow LED indicates that the relay is energized. Connections are made via screw terminals, with two terminals for 1.5 mm² with cable end ferrules and two for 2.5 mm² without cable end ferrules. The tightening torque is 0.6 to 1 Nm, ensuring secure and reliable connections.
Technology Explained Simply
The time relay operates electronically and is designed for high reliability. The time delay is controlled by an integrated timer, adjusted via the rotary knob on the front panel. The star-delta start function allows the motor to be started in star mode to reduce starting current, then switched to delta mode after the set time to achieve full power. Settings are accessible via the front panel, with the transparent cover protecting against unintended changes. LED indicators provide visual feedback on the operating status, simplifying maintenance and diagnostics. Insulation resistance is 100 MΩ at 500 V DC, and the rated impulse voltage withstand is 5 kV for 1.2 to 50 µs. Voltage withstand is 2.5 kV at 1 mA/1 minute at 50 Hz. Shock resistance is 15 Gn for 11 ms, and vibration resistance is 20 m/s² in the frequency range of 10 to 150 Hz.
Compatibility and Accessories
The device is compatible with other products in the Harmony Time series and can be used in combination with other time relays such as the RE22R1QMQ or RE22R2MYMR. These models offer extended functions such as multifunctionality or NFC adjustment, with specific uses varying between models. Mounting is on a 35 mm DIN rail, enabling universal integration into existing enclosures. The protection rating is IP40 for the housing and front, and IP20 for the terminal block, providing protection against touch and dust, but not against water. The mounting position is arbitrary relative to a vertical mounting plate.
Mounting and Installation
Mounting is on a 35 mm DIN rail, with a width of 22.5 mm allowing for compact placement. Cable connections are made via screw terminals, with designated cross-sections (1.5 mm² with cable end ferrules, 2.5 mm² without cable end ferrules) ensuring secure and durable connections. The tightening torque of 0.6 to 1 Nm must be observed to ensure reliable connections. The front panel with the rotary knob is easily accessible, and the transparent cover can be removed to make adjustments. LED indicators allow for quick visual inspection of the operating status. Installation is in a closed enclosure, with ambient conditions (temperature, humidity) remaining within the specified limits.
Operational Advantages
The time relay offers high reliability with an MTTFd of 182.6 years and a B10d value of 170,000, emphasizing its longevity and stability. Adjustment options are diverse and cover a wide time range, from milliseconds to 100 hours. LED indicators simplify diagnostics and maintenance, and the IP40 protection rating provides sufficient protection for industrial environments. Mounting on the DIN rail enables flexible integration into existing systems. The versatile supply voltage allows the device to be used in various installation configurations. The mechanical and electrical life, along with high insulation and shock resistance values, guarantee robust and long-term performance.