| Additional features |
| Network frequency | 50 Hz |
| [Ue] Operational rated voltage | 230 V AC 50 Hz |
| [Ui] Rated insulation voltage | 440 V |
| [Uimp] Rated impulse voltage withstand | 4 kV |
| Inrush current | 250 A |
| Control type | Toggle switch |
| Local signalling | ON/OFF indicator |
| Mounting mode | Plug-in |
| Mounting bracket | DIN rail |
| Compatibility of comb rails and distribution blocks | Bottom: dual-function terminal |
| 9-mm pitch | 4 |
| Height | 81 mm |
| Width | 36 mm |
| Depth | 78,5 mm |
| Product weight | 0,18 kg |
| Colour | White |
| Mechanical life | 20000 cycles |
| Electrical lifetime | 10000 cycles |
| Connections - terminals | Tunnel terminals (top or bottom) - 1 - 25 mm² - flexible with ferrule; Tunnel terminals (top or bottom) - 1 - 25 mm² - flexible; Tunnel terminals (top or bottom) - 1 - 35 mm² - solid |
| [M] tightening torque | 3.5 Nm top or bottom |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | Resi9 |
| Product name | Resi9 RCCB |
| Product or component type | Residual current circuit breaker (RCCB) |
| Pole description | 2P |
| Neutral position | Left |
| [In] Rated current | 25 A |
| Type of network | AC |
| Earth fault sensitivity | 10 mA corresponds to EN/IEC 61008-2-1 |
| Earth fault protection time delay | Instantaneous |
| Earth fault protection class | Type A |
| Rated breaking force and rated power | IM 500 A corresponds to EN/IEC 61008-2-1 |
| Conditional rated short-circuit current | 10 kA |
| Conformity marking | VDE |
| Mounting |
| Standards | EN/IEC 61008-2-1 |
| Degree of protection (IP) | IP20 corresponds to IEC 60529; IP40 (modular housing) corresponds to IEC 60529 |
| Pollution degree | 2 |
| Operating ambient temperature | -25…40 °C |
| Ambient temperature during storage | -40…60 °C |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 4,200 cm |
| VPE 1 width | 8,100 cm |
| VPE 1 length | 9,100 cm |
| Packaging weight (Lbs) | 208,000 g |
| VPE 2 type | S03 |
| VPE 2 quantity | 54 |
| VPE 2 height | 30,000 cm |
| VPE 2 width | 30,000 cm |
| VPE 2 length | 40,000 cm |
| VPE 2 weight | 11,558 kg |
| VPE 3 type | P12 |
| VPE 3 quantity | 432 |
| VPE 3 height | 45,000 cm |
| VPE 3 width | 80,000 cm |
| VPE 3 length | 120,000 cm |
| VPE 3 weight | 108,000 kg |
Residual current circuit breaker Resi9. 1 pole + N, 25A, nominal residual current 10mA, type A. Conditional rated short-circuit current (Inc/I¿c) 10,000A, in accordance with EN 61008. Operating voltage (Ue) 230V AC, operating frequency 50 Hz, neutral position on the left. Dual function terminal for cable and fork comb rail on the underside of the device. Rear top hat rail fastening element on the underside of the device. Snap action for low-wear switching of the contacts that is independent of the user. Color RAL 9003.