| Additional features |
| Hue | White (RAL 9003) |
| Form factor | Monoconnect |
| Mounting mode | By screws (clamps) |
| Electrical connection (voltage sensing & power supply) | Plug pin and wire |
| Cable cross-section | 1 fixed cable 1.5…16 mm²; 2 stranded cable 1.5…2.5 mm²; 2 fixed cable 1.5…2.5 mm²; 1 stranded cable 1.5…16 mm² |
| Cable length | 1 m |
| Supply voltage | 200 - 240 V AC, ± 20 % |
| Cable composition | 1 x 0,33 mm² |
| Network frequency | 50 Hz; 60 Hz |
| Maximum power consumption | 1 VA |
| Standards | IEC 61557-12; IEC 61010-1; IEC 61010-2-030; IEC 61326-1; ETSI EN 300 328; ETSI EN 301 489-1 |
| Height | 16,5 mm |
| Width | 18 mm |
| Depth | 43 mm |
| Product weight | 16,4 g |
| Colour | White (RAL 9003) |
| Main colour tone | White |
| Total power losses | 0,9 W |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | PowerLogic |
| Product name | PowerTag R9 M63 |
| Product or component type | Energy sensor |
| Poles | 1P |
| [Imax] max. current | 63 A |
| Name of mobile app | Wiser by SE; Wiser Home |
| [Ib] base current | 10 A |
| Input current | 40 mA |
| Saturation current | 130 A |
| Product-specific application | Load monitoring; Power circuit monitoring; Overload alarm; Monitoring of energy generation (photovoltaic); Energy management |
| Concentrator compatibility | Wiser hub Generation 1; Wiser hub Generation 2 |
| Application | Building: power circuit breaker voltage monitoring; Building: overload alarm |
| Compatible product family | Resi9 |
| Measured value type | Voltage; Active energy; Current |
| Accuracy class | Class 1 current corresponds to IEC 61557-12; Class 0.5 voltage corresponds to IEC 61557-12; Class 1 active energy corresponds to IEC 61557-12 |
| Mounting location | Top or bottom |
| Mounting bracket | for circuit breaker |
| Product application | Switchgear |
| Event management | Voltage drop with measured current during voltage drop |
| Transmission medium | Radio frequency 2.4…2.4835 GHz corresponds to IEEE 802.15.4 |
| Transmit power | 10 mW |
| Mounting |
| Conformity marking | CE |
| Policies | 2014/53/EU - Radio Equipment Directive |
| Operating altitude | 0 - 2.000 m |
| Operating ambient temperature | -25…60 °C |
| Ambient temperature during storage | -40…85 °C |
| Over voltage category | III corresponds to IEC 61010-1 |
| Measurement category | Category III corresponds to IEC 61010-2-030 |
| Degree of protection (IP) | IP20 complies with IEC 60529 |
| Degree of protection (IK) | IK05 |
| Pollution degree | 3 |
| Relative humidity | 0…95 % at 45 °C corresponds to IEC 60721-3-3 |
| Vibration resistance | 3M4 corresponds to IEC 60721-3-3 |
| Electromagnetic compatibility | Electromagnetic environment in residential areas complies with IEC 61326-1; Radiated disturbances comply with ETSI EN 301 489-17; Electromagnetic emissions comply with IEC 62311 |
| Environmental properties | dust resistant Class 3S3 corresponds to IEC 60721-3-3; salt fog Class 3C2 corresponds to IEC 60721-3-3; for indoor use |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 5,000 cm |
| VPE 1 width | 6,000 cm |
| VPE 1 length | 8,500 cm |
| Packaging weight (Lbs) | 38,000 g |
| VPE 2 type | S02 |
| VPE 2 quantity | 48 |
| VPE 2 height | 15,000 cm |
| VPE 2 width | 30,000 cm |
| VPE 2 length | 40,000 cm |
| VPE 2 weight | 2,134 kg |
PowerTag Resi9 M63 1-pin with pin connection + N-cable, 220 - 240 V AC +/- 20%, between phase and neutral, Imax 63A Connection to the Wiser Hub via radio connection - ISM Band 2.4 GHz to 2.4835 GHz Installation from above or below on a Resi9 circuit breaker Energy sensors for transmitting the energy data to the Wiser Hub Accuracy class 1