Further information for Schneider Electric R9DX01610 residual current circuit breaker 1P+N 10 A
Additional features
Device position in system
Outlet
Network frequency
50 Hz
[Ue] Operational rated voltage
230 V AC
Magnetic trip threshold
3 - 5 x In0AC
Earth fault trip technology
Voltage-independent
[Ics] Rated operational breaking capacity
6000 A 100 % - 230 V AC
Rated breaking force and rated power
Icn 6000 A at 230 V AC corresponds to EN/IEC 61009-2-1
Limiting class
3
[Ui] Rated insulation voltage
440 V AC
[Uimp] Rated impulse voltage withstand
4 kV
Inrush current
250 A
Control type
Toggle switch
Local signalling
ON/OFF indicator
Mounting mode
Plug-in
Mounting bracket
DIN rail
Terminal pitch
9 mm
9-mm pitch
2
Height
91 mm
Width
18 mm
Depth
69 mm
Product weight
125 g
Colour
White (RAL 9003)
Mechanical life
10000 cycles
Electrical lifetime
10000 cycles
Description of locking options
Padlock; Sealing possible
Connections - terminals
Tunnel terminals (top or bottom) - 1 - 16 mm² - solid; Tunnel terminals (top or bottom) - 1 - 10 mm² - stranded; Tunnel terminals (top or bottom) - 1 - 10 mm² - stranded with ferrule
Wire stripping length
12 mm for top or bottom connection
[M] tightening torque
2 Nm top or bottom
Earth fault protection
Integrated
Contact position indicator
Compatibility of comb rails and distribution blocks
Provisions for padlocks
Contractual warranty
Warranty (in months)
18
Main features
Product series
Resi9
Product name
Resi9 RCBO
Product or component type
Residual current circuit breaker with overcurrent protection (FI/LS)
Device short name
Resi9 RCBO
Device application
Distribution
Pole description
1P + N
Neutral position
Left
Number of protected poles
1
[In] Rated current
10 A at 30 °C
Earthing system
TN-S; TT; TN-C-S; TN
Type of network
AC
Trigger technology
Thermal-magnetic
Cam disc
B
Earth fault sensitivity
30 mA
Earth fault protection time delay
Instantaneous
Earth fault protection class
Type A
Breaking capacity
6000 A Icn at 230 V AC 50 Hz conforms to EN/IEC 61009-2-1
Conformity marking
VDE; KEMA
Suitability for insulation
Mounting
Standards
EN/IEC 61009-1; EN/IEC 61009-2-1
Degree of protection (IP)
IP20; IP40 (modular housing)
Degree of protection (IK)
IK05
Pollution degree
2
Over voltage category
III
Electromagnetic compatibility
8/20 µs impulse resistance, 250 A corresponds to EN/IEC 61009-2-1
Drip-proof
2 corresponds to IEC 60068-1
Relative humidity
95 % at 55 °C
Operating altitude
2.000 m
Operating ambient temperature
-25…60 °C
Ambient temperature during storage
-40…80 °C
Packaging units
VPE 1 type
PCE
Number of devices per package
1
VPE 1 height
11,4 cm
VPE 1 width
2,2 cm
VPE 1 length
8,1 cm
Packaging weight (Lbs)
138 g
VPE 2 type
S02
VPE 2 quantity
45
VPE 2 height
15 cm
VPE 2 width
30 cm
VPE 2 length
40 cm
VPE 2 weight
6,51 kg
VPE 3 type
P12
VPE 3 quantity
720
VPE 3 height
45 cm
VPE 3 width
80 cm
VPE 3 length
120 cm
VPE 3 weight
116,16 kg
Optimaler Fehlerstromschutz für Personen und Anlagen mit unserem neuen kompakten Resi9 Typ A FI-LS 1P+N 10A von Schneider Electric. Eingesetzt wird dieser kompakte FILS 1TE (18mm) bei einer Netzfrequenz von 50Hz und einer Betriebsspannung von 230V AC. B, mit einem Kurzschlussvermögen von 6kA bei 230V AC nach EN/IEC 61009-2-1 Standard. Nennfehlerstrom 30 mA, Typ A, Löst bei AC-Fehlerströmen aus und geht nicht in die Sättigung bis 6mA DC-Fehlerströme. Einsetzbar bei einer Betriebstemperatur von -25°C bis 60°C. Mechanische rote Anzeige bei Fehlerauslösung des LS-Schalters und seperaten mechanische rote Anzeige bei Fehlerstromauslösung des FI-Schutzschalters an der Frontseite des Gerätes. Die Prüftaste ist mit einem 'T' markiert. Beim drücken dieser Taste kann die Funktionalität des Schutzgerätes getestet werden. Die Resi9 FILS Serie bietet den bestmöglichen Schutz im Wohnbau.