Further information for Schneider Electric R9D01613 FI/LS switch 1P+N
Additional features
Network frequency
50/60 Hz
[Ue] Operational rated voltage
230 V
Magnetic trip threshold
3 - 5 x In
[Ui] Rated insulation voltage
400 V
Inrush current
250 A
Control type
Toggle switch
Local signalling
ON/OFF indicator
Mounting mode
Plug-in
Mounting bracket
DIN rail
9-mm pitch
4
Height
82 mm
Width
36 mm
Depth
70,5 mm
Product weight
186 g
Colour
White
Mechanical life
20000 cycles
Electrical lifetime
7500 cycles
Connections - terminals
Tunnel terminals (top or bottom) - 1 - 16 mm² - solid; Tunnel terminals (top or bottom) - 1 - 10 mm² - stranded; Tunnel terminals (top or bottom) - 1 - 10 mm² - stranded with ferrule
Wire stripping length
13 mm for top or bottom connection
[M] tightening torque
2 Nm
Earth fault protection
Integrated
Provisions for padlocks
Contractual warranty
Warranty (in months)
18
Main features
Product series
Resi9
Product name
Resi9 RCBO
Product or component type
Residual current circuit breaker with overcurrent protection (FI/LS)
Device application
Distribution
Pole description
1P + N
Neutral position
Left
Number of protected poles
1
[In] Rated current
13 A
Type of network
AC
Trigger technology
Thermal-magnetic
Cam disc
B
Earth fault sensitivity
30 mA
Earth fault protection time delay
Instantaneous
Earth fault protection class
Type A
Breaking capacity
6000 A Icn at 230 V AC 50 Hz conforms to EN/IEC 61009-2-1
Conformity marking
VDE
Mounting
Standards
EN/IEC 61009-1; EN/IEC 61009-2-1
Degree of protection (IP)
IP20
Over voltage category
III
Drip-proof
2 corresponds to IEC 60068-1
Relative humidity
95 % at 55 °C
Operating ambient temperature
-25…40 °C
Ambient temperature during storage
-40…60 °C
Packaging units
VPE 1 type
PCE
Number of devices per package
1
VPE 1 height
4,100 cm
VPE 1 width
8,500 cm
VPE 1 length
10,000 cm
Packaging weight (Lbs)
210,000 g
VPE 2 type
S03
VPE 2 quantity
60
VPE 2 height
30,000 cm
VPE 2 width
30,000 cm
VPE 2 length
40,000 cm
VPE 2 weight
13,188 kg
Residual current circuit breaker Resi9. 1 pole + N, 13A. B characteristic, nominal residual current 30 mA, type A, rated breaking capacity 6kA, in accordance with EN/IEC 61009-1. Operating voltage (Ue) 230V AC, operating frequency 50 Hz, neutral position on the left. Residual current circuit breaker with integrated circuit breaker. Mechanical red indicator when the circuit breaker is tripped and separate mechanical red indicator when the residual current circuit breaker is tripped on the front of the device. Color RAL 9003.