| Complementary |
| Power quality analysis | conforming to EN 50160: 2010 compliance report; conforming to IEEE 519: 2014 compliance report; conforming to IEC 61000-4-30: class S power quality measurement; up to the 63rd harmonic; harmonic distortion; waveform capture; voltage sag and swell detection; programmablity (logic and math functions); conforming to IEC 62586 power quality monitoring; disturbance direction detection; rapid voltage change |
| Device application | WAGES metering; Power monitoring |
| Type of measurement | Current; Voltage; Frequency; Active and reactive power total; Apparent power total; Power factor total; Active and reactive power per phase, rms; Apparent power per phase, rms; Power factor per phase, rms |
| supply voltage | 90...415 V AC 45...65 Hz +/- 10 %; 110...415 V DC +/- 10 % |
| Network frequency | 50 Hz; 60 Hz |
| [In] rated current | 10 A; 5 A; 1 A |
| Poles description | 3P; 1P + N; 3P + N |
| Power consumption in VA | 16 VA at 230 V AC |
| Display type | Remote LCD display |
| Display resolution | 320 x 240 pixels QVGA |
| Sampling rate | 256 samples/cycle |
| Measurement current | 50…10000 mA |
| Analogue input type | Voltage (impedance 5 MOhm); Current (impedance 0.3 mOhm) |
| Measurement voltage | 57…400 V AC 42...69 Hz between phase and neutral; 100…690 V AC 42...69 Hz between phases |
| Frequency measurement range | 42…69 Hz |
| Number of inputs | 3 digital 30 V AC; 3 digital 60 V DC |
| Measurement accuracy | Current +/- 0.1 %; Voltage +/- 0.1 %; Active energy +/- 0.2 % |
| Accuracy class | Class 0.2S active energy conforming to IEC 62053-22; Class 0.2 active energy conforming to ANSI C12.20; Class 0.2 active power conforming to IEC 61557-12; Class 0.5S reactive energy conforming to IEC 62053-24; Class 0.5 power factor conforming to IEC 61557-12; Class 0.2 voltage conforming to IEC 61557-12; Class 0.2 current conforming to IEC 61557-12 |
| Number of outputs | 1 pulse |
| Information displayed | Voltage; Current; Frequency; Power; Energy consumption; Harmonic distortion |
| Communication port protocol | Modbus RTU at 115 kbauds - 2-wire; ION at 115 kbauds - 2-wire; DNP3; IEC 61850; Modbus TCP/IP; Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s; RSTP 801.1d 2004 |
| Communication port support | ETHERNET; Screw terminal block: RS485 |
| Communication network type | IPv6 (internet protocol) |
| Data recording | Sequence of event recording; Event logs; Min/max of instantaneous values; Harmonics logs; Alarm logs; GPS synchronisation; Waveform logs; Data logs; Time stamping; Trending/forecasting; Sag and swell logs; 50 data recorders |
| Memory capacity | 512 MB |
| Web services | Customizable home page; File upload/download via FTP; File upload/download via SFTP; Web server; Alarm notification by e-mail; Viewing of captured waveform (FTP); Viewing of captured waveform (web); HTTPS server |
| Communication service | SMTP e-mail notification; RSTP support; NTP time synchronization; DHCP; PTP time synchronization |
| Cybersecurity | Password protection; Syslog protocol support; Port hardening; Robust security logs; Enable/disable communication ports |
| Mounting mode | Flush-mounted; Clip-on |
| Mounting support | DIN rail meter device; Framework remote display |
| Provided equipment | Remote display |
| Installation category | III |
| Safety Construction | III400…690 V conforming to IEC 61010-1:ed. 3; III400…690 V conforming to EN 61010-1:ed. 3; III347…600 V conforming to UL 61010-1:ed. 3; III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3 |
| Standards | IEC 62053-22; IEC 62053-24; IEC 62052-11; IEC 61557-12; IEEE 1588; IEC 62586-2; IEC 61326-1 |
| Product certifications | CE; CULus; N998 |
| Width | 90.5 mm |
| Depth | 90.8 mm |
| Height | 90.5 mm |
| Net weight | 528 g |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| IP degree of protection | IP30 conforming to IEC 60529 |
| Relative humidity | 5…95 % |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Operating altitude | 3000 m |
| Compatibility code | PM8244 |
| Logistical informations |
| Country of origin | CA |
| Main |
| Range | PowerLogic |
| Product name | PowerLogic PM8000 |
| Product or component type | Power meter |
| Device short name | PM8244 |
| model type | Standard |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 13.800 cm |
| Package 1 Width | 14.000 cm |
| Package 1 Length | 36.800 cm |
| Package 1 Weight | 1.305 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.212 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 32 |
| Package 3 Height | 45.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 61.696 kg |
The PowerLogic PM8244 is a DIN rail power analyzer for low and medium voltage applications with a remote display for front mounting 96 x 96 mm and AC/DC control voltage. It is designed to ensure the availability and efficiency of your energy-critical systems. It creates energy transparency and provides actionable data on complex power quality conditions. The modular, flexible and powerful ION technology allows individual applications to be created for each measuring device. It has high accuracy, multiple communication ports, a web-based user interface and a graphical color display. This power analyzer also has integrated power quality analysis and patented fault direction detection. Certified by independent laboratories for Class 0.2S accuracy for active energy (IEC62052-11, IEC62053-24, IEC62053-22). Also certified for power quality (IEC62586-2, IEC61000-4-30 Class S). Cybersecurity features include secure protocols (HTTPs, sFTP, Secure ION), security event logging, Syslog protocol. Ability to enable/disable communication ports and support for 50 configurable user accounts to manage access. With 512MB memory for up to 50 data logs (800 channels), 50+ user-definable alarms, waveform recordings up to 256 samples/cycle, 1/2 cycle root mean square (RMS) logging. Memory can also be used for custom web pages, min/max logs, energy trends and run hours. Time stamping for events with +/-1ms accuracy using time synchronization. Time synchronization methods that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time setting function. 3 digital inputs and one digital output, plus the ability to add up to 4 option modules. The input/output option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Wide control voltage range of 90-415 VAC / 110-415 VDC. Operating environment from -25 to +70°C, humidity from 5% to 95% and operating altitude up to 3000 m.