Schneider Electric METSEPM5100, EAN: 3606480621239

Schneider Electric METSEPM5100 meter without Modbus

Measurement > Counter / coin, hour meter

Schneider Electric METSEPM5100 meter without Modbus

Lieske Part No. 557462
Mfg Part No METSEPM5100
EAN-Code 3606480621239
Manufacturer Schneider Electric
Here only 235,60 EUR
280,36 EUR incl. VAT

Further information for Schneider Electric METSEPM5100 meter without Modbus

Complementary
Power quality analysisup to the 15th harmonic
Device applicationPower monitoring
Type of measurementCurrent; Voltage; Frequency; Power factor; Energy; Active and reactive power
[Us] rated supply voltage90...450 V AC 45...65 Hz; 100...300 V DC
Network frequency60 Hz; 50 Hz
[In] rated current5 A; 1 A
type of network3P + N; 1P + N; 3P
Maximum power consumption in VA11 VA at 415 V
Ride-through time80 ms 120 V AC typical; 100 ms 230 V AC typical; 100 ms 415 V AC typical; 50 ms 125 V DC typical
Display typeMonochrome graphic LCD
Display resolution128 x 128 pixels
Sampling rate64 samples/cycle
Measurement current50…8500 mA
Analogue input typeVoltage (impedance 5 MOhm); Current (impedance
Measurement voltage35…760 V AC 45...65 Hz between phases; 20…400 V AC 45...65 Hz between phase and neutral
Frequency measurement range45…65 Hz
Number of inputs0
Measurement accuracyActive energy +/- 0.5 %; Reactive energy +/- 2 %; Active power +/- 0.5 %; Apparent power +/- 0.5 %; Frequency +/- 0.05 %; Power factor +/- 0.5; Current +/- 0.5 %; Voltage +/- 0.5 %; Apparent energy +/- 0.5 %; Reactive power +/- 2 %
Accuracy classClass 0.5S active energy conforming to IEC 62053-22
Number of outputs1 pulse (energy)
Communication port protocol-
Communication port support-
Data recordingMin/max of instantaneous values; Time stamping
Connections - terminalsVoltage circuit: screw terminal block4; Control circuit: screw terminal block2; Current transformer: screw terminal block6; Input/output circuit: screw terminal block6; RS485 link: screw terminal block4
Mounting modeFlush-mounted
Mounting supportFramework
StandardsEN 50470-1; IEC 62053-22:2020; UL 61010-1; IEC 62053-24; IEC 61557-12:2015; EN 50470-3; IEC 60529; IEC 62053-23:2020; IEC 62052-11:2020; IEC 62052-31:2015
Product certificationsCE conforming to IEC 61010-1; CULus conforming to UL 61010-1
Width96 mm
Depth72 mm
Height96 mm
Net weight380 g
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP54 display: conforming to IEC 60529; IP30 rear: conforming to IEC 60529
Relative humidity5…95 % at 50 °C non-condensing
Pollution degree2
Ambient air temperature for operation-25…70 °C meter; -20…70 °C display; -25…-20 °C (with reduced performance) display
Ambient air temperature for storage-40…85 °C
Operating altitude2000 m CAT III
Logistical informations
Country of originIN
Main
RangePowerLogic
Product namePowerLogic PM5000
Product or component typePower meter
Device short namePM5100
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height12.000 cm
Package 1 Width13.000 cm
Package 1 Length13.000 cm
Package 1 Weight477.000 g
Unit Type of Package 2S03
Number of Units in Package 212
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.331 kg
Unit Type of Package 3P06
Number of Units in Package 396
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight61.436 kg
The PowerLogic PM5100 from Schneider Electric is a universal measuring device for front mounting in enclosures, designed for current monitoring in industrial and commercial installations. It features an integrated, monochrome graphic LCD display with a resolution of 128 x 128 pixels, which is backlit and thus remains clearly readable even in poor lighting conditions. The device is designed for use in networks with 50 Hz or 60 Hz and supports various network types, including 1P + N, 3P, and 3P + N. The supply voltage ranges from 90 to 450 V AC (45–65 Hz) as well as 100 to 300 V DC, making it flexible for use in different electrical systems.

Applications

The PM5100 is suitable for monitoring and measuring electrical parameters in installations with a voltage of 35 to 760 V AC between phases and 20 to 400 V AC between phase and neutral conductor. It is designed for measurements in industrial environments, energy distribution systems, and for monitoring machines and installations where precise energy balancing and power quality analysis are required. Measurement is performed at a sampling rate of 64 samples per cycle, enabling precise capture of electrical parameters.

Functions and Equipment in Detail

The device measures active and reactive power, apparent power, voltage, current, frequency, power factor, as well as active and reactive energy. It offers 4-quadrant energy measurement, meaning it captures energy flows in both forward and reverse directions. Measurement accuracy is ± 0.5 % for active energy, active power, apparent power, voltage, current, and frequency, and ± 2 % for reactive energy and reactive power. The accuracy class 0.5S for active energy corresponds to the standard IEC 62053-22. Additionally, the device analyzes power quality up to the 15th harmonic, which is important for detecting harmonics and disturbances in the network.

Technology Explained Simply

Measurement is performed via an integrated current transformer connection equipped with screw terminal strips. The rated currents are 1 A or 5 A, with a current measurement range from 50 to 8500 mA. The maximum power consumption is 11 VA at 415 V AC. The response time varies depending on voltage: typically 80 ms at 120 V AC, 100 ms at 230 V AC and 415 V AC, and 50 ms at 125 V DC. The device includes a pulse output for energy transmission, which can be used for external metering or control systems. Data logging includes minimum and maximum values of real-time parameters with timestamping, enabling later analysis.

Compatibility and Accessories

The PM5100 is compatible with a wide range of current transformers available for different rated currents and mounting types. These include, for example, current transformers for 200/5 A, 100/5 A, 40/5 A, 50/5 A, 75/5 A, 250/5 A, 300/5 A, 400/5 A, 600/5 A, 800/5 A, 1250/5 A, 2000/5 A, 2500/5 A, and 5000/5 A. These transformers allow adaptation to various load currents and installation scenarios, such as cables or busbars. Communication occurs exclusively via the pulse output; there is no integrated network function such as Modbus or other protocols.

Mounting and Installation

The device is mounted flush into enclosures with a front opening of 96 mm x 96 mm. Mounting is done via frame conditions, with connections made via screw terminal strips. The protection rating is IP54 at the display (according to IEC 60529) and IP30 at the rear. The operating environment must have a relative humidity of 5 to 95 % at 50 °C (non-condensing) and an ambient temperature between -25 °C and 70 °C. The display can operate at temperatures from -20 °C to 70 °C; performance is reduced between -25 °C and -20 °C. The operating altitude is up to 2000 m above sea level in category CAT III.

Operational Advantages

The PM5100 offers high measurement accuracy and comprehensive analysis of electrical parameters, including power quality up to the 15th harmonic. The integrated data logging with timestamping enables detailed analysis of load profiles. The 33 configurable alarms support early detection of operational deviations. The robust construction and compliance with international standards such as IEC 62053-22, IEC 62053-24, IEC 61557-12:2015, EN 50470-1, EN 50470-3, and IEC 60529 ensure reliability and safety. The device is certified with CE and CULus, confirming compliance with relevant safety and functional requirements.