| Complementary |
| Power quality analysis | up to the 15th harmonic |
| Device application | Multi-tariff; Power monitoring; Sub billing |
| Type of measurement | Active and reactive power; Apparent power; Current; Voltage; Energy; Power factor; Frequency; Total current harmonic distortion THD (I); Total voltage harmonic distortion THD (U) |
| supply voltage | 100...277 V AC 45...65 Hz; 173...480 V AC 45...65 Hz; 100...300 V DC |
| Network frequency | 60 Hz; 50 Hz |
| [In] rated current | 5 A; 1 A |
| type of network | 3P; 3P + N; 1P + N |
| Power consumption in VA | 5 VA |
| Display type | Backlit LCD |
| Display resolution | 128 x 96 pixels |
| Sampling rate | 32 samples/cycle |
| Measurement current | 0.02…1.2 A; 0.05…6 A |
| Analogue input type | Current 0...5 A; Current 0...1 A |
| Measurement voltage | 50…330 V AC 45...65 Hz direct; 50…330 V AC 45...65 Hz phase to neutral; 80…570 V AC 45...65 Hz direct; 80…570 V AC 45...65 Hz phase to phase; 570…999000 V AC 45...65 Hz with external VT |
| Frequency measurement range | 45…65 Hz |
| Number of inputs | 2 digital 0...4 mA 11...40 V DC |
| Measurement accuracy | Current 0.3 % 0.5...6 A; Current 0.5 % 0.1...1.2 A; Voltage 0.3 % 50...330 V; Voltage 0.3 % 80...570 V |
| Accuracy class | Class 0.5S active energy conforming to IEC 62053-22; Class 1 active energy conforming to IEC 62053-21; Class 2 reactive energy conforming to IEC 62053-23; Class C active energy conforming to EN 50470-3 |
| Number of outputs | 2 digital (static) |
| Information displayed | Tariff (4) |
| Communication port protocol | Modbus at 9.6...38.4 kbauds |
| Communication port support | RS485 |
| Data recording | Energy consumption logs; 15 alarms; Power logs; Time stamping; Min/max of instantaneous values |
| Memory capacity | 512 KB |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| Standards | BS EN 61557-12; IEC 61557-12; EN 61557-12; BS EN 61326-1; IEC 61326-1; EN 61326-1; BS EN 62052-11; IEC 62052-11; EN 62052-11; BS EN 62053-21; IEC 62053-21; EN 62053-21; BS EN 62053-22; IEC 62053-22; EN 62052-22; BS EN 62053-23; IEC 62053-23; EN 62052-23; BS EN 61010-1; EN 61010-1; IEC 61010-1; UL 61010-1; BS EN 61010-2-30; IEC 61010-2-30; EN 61010-2-30; UL 61010-2-30; ANSI C12.20 |
| Product certifications | CE conforming to IEC 61010-1 (safety); CE conforming to EN 61557-12 (power monitor); CE conforming to EN/IEC 61326-1 (EMC); UKCA conforming to BS EN 61010-1 (safety); UKCA conforming to BS EN 61557-12 (power monitor); UKCA conforming to BS EN 61326-1 (EMC); CULus conforming to EN 61010-1 (safety); CULus conforming to UL 61010-1 (safety); EAC (sub-meter); RCM |
| Width | 90 mm |
| Depth | 70 mm |
| Height | 95 mm |
| Net weight | 0.26 kg |
| Market segment | Small commercial; Residential |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Electromagnetic compatibility | Electrostatic discharge level 4 conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; Surge immunity test level 4 conforming to IEC 61000-4-5; Conducted RF disturbances level 3 conforming to IEC 61000-4-6; Magnetic field at power frequency - test level: 0.5 mT conforming to IEC 61000-4-8; Conducted and radiated emissions class B conforming to EN 55022 |
| Overvoltage category | III |
| IP degree of protection | IP40 front panel: conforming to IEC 60529; IP20 body: conforming to IEC 60529 |
| Relative humidity | 5…95 % at 50 °C |
| Pollution degree | 2 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Operating altitude | < 3000 m |
| Compatibility code | PM3255 |
| Logistical informations |
| Country of origin | CN |
| Main |
| Range | PowerLogic |
| Product name | PowerLogic PM3000 |
| Product or component type | Power meter |
| Device short name | PM3255 |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 9.400 cm |
| Package 1 Width | 13.900 cm |
| Package 1 Length | 14.000 cm |
| Package 1 Weight | 422.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 7.036 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 384 |
| Package 3 Height | 95.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 177.864 kg |
The
PowerLogic PM3255 from Schneider Electric is a
universal measuring device for
energy monitoring in buildings and small businesses. It is designed for precise measurement and analysis of electrical parameters in single-phase, single-phase with neutral conductor, and three-phase networks. The device is designed for mounting on a
DIN rail and is suitable for use in enclosures or distribution boxes. It features a
backlit LCD display with a resolution of 128 x 96 pixels, enabling the display of measured values, tariffs, and status information.
Applications include
current monitoring,
partial billing, and
multitariff measurement, making it suitable for applications in building automation, industrial energy management, and energy consumption billing in various tariff zones. The device measures
active and reactive power,
apparent power,
current,
voltage,
energy,
power factor,
frequency,
total harmonic distortion THD (I), and the
sum of harmonic voltages THD (U). Network quality analysis is performed up to the 15th harmonic, enabling detailed evaluation of power quality.
Functions and equipment in detail include an
accuracy class 0.5S for active energy according to IEC 62053-22, ensuring high measurement accuracy for energy billing. Measurement accuracy is 0.3 % for current in the range 0.5–6 A and 0.5 % in the range 0.1–1.2 A. For voltage measurements, accuracy is 0.3 % in the range 50–330 V and 80–570 V. The device supports
4-quadrant energy measurement, enabling energy capture in both directions (consumption and feed-in). The
sampling rate is 32 samples per cycle, ensuring fast and precise capture of AC signals.
Technology explained simply shows that the device can be operated with a
supply voltage of 100–277 V AC, 173–480 V AC, or 100–300 V DC. The
network frequency can be 50 Hz or 60 Hz. The
rated current is available in 1 A or 5 A, with a current measurement range of 0.02–1.2 A and 0.05–6 A. Direct voltage measurement ranges from 50–570 V AC, and with an external voltage transformer (VT), voltages up to 999000 V AC can be measured.
Frequency measurement is performed in the range 45–65 Hz.
Compatibility and accessories include support for
Modbus RTU and ASCII via an
RS485 interface with baud rates from 9.6 to 38.4 kBaud. The device features
two digital inputs (0–4 mA, 11–40 V DC) and
two digital outputs (static), which can be used for integration into control and monitoring systems.
Data logging includes energy consumption logs, power logs, timestamping, and storage of minimum and maximum values of real-time values. The
memory capacity is 512 kB, allowing up to 15 alarms and detailed measurement data to be logged.
Mounting and installation are performed by snap-on mounting on a DIN rail. The device is designed for an
operating temperature of -25 to 70 °C and can be stored at a
storage temperature of -40 to 85 °C. The
operating altitude is limited to below 3,000 m. The
protection rating is IP40 on the front panel and IP20 on the housing, providing protection against contact and dust, but not against water. The
relative humidity is 5–95 % at 50 °C. The device complies with standards
IEC 61557-12,
IEC 61326-1,
IEC 62052-11,
IEC 62053-21,
IEC 62053-22,
IEC 62053-23,
IEC 61010-1,
UL 61010-1,
ANSI C12.20, as well as corresponding EN- and BS-standards. Certifications include CE, UKCA, CULus, and RCM.
Operational advantages lie in high measurement accuracy, comprehensive data logging, and easy integration into existing systems via Modbus. The 4-quadrant measurement enables detailed energy balancing, and network quality analysis up to the 15th harmonic supports identification of disturbances in the power network. The robust construction and compliance with international standards ensure reliable and safe use in industrial and commercial applications.
The
dimensions are 90 mm (width), 70 mm (depth), and 95 mm (height), and the
weight is 0.26 kg. The device is designed for use in enclosures and distribution boxes and offers a compact yet powerful solution for energy monitoring.