Schneider Electric METSEION95030, EAN: 3606481352347

Schneider Electric METSEION95030 power analyzer ION9000T

Schneider Electric METSEION95030 power analyzer ION9000T

Lieske Part No. 998835
Mfg Part No METSEION95030
EAN-Code 3606481352347
Manufacturer Schneider Electric
Here only 6.558,45 EUR
7.804,56 EUR incl. VAT

Further information for Schneider Electric METSEION95030 power analyzer ION9000T

Complementary
Power quality analysisEN 50160 compliance checking; conforming to IEEE 519 harmonic limit; conforming to IEC 61000-4-30: class A compliance reporting; conforming to IEEE 519 compliance reporting; waveform capture; total demand distortion; total harmonic distortion; up to the 63rd harmonic; up to the 127th harmonic with software; disturbance direction detection; dip, swell and transient; half cycle data acquisition; high-speed transient capture; coincidence disturbance waveform capture; transient detection (100 ns)
Type of measurementVoltage sags and swells; Current sags and swells; Voltage; Current; Frequency; Active and reactive power total; Apparent power total; Active and reactive power per phase; Apparent power per phase; Power factor total; Power factor per phase; Active and reactive energy; Apparent energy; Harmonic distortion (I THD & U THD)
[Us] rated supply voltage90...480 V AC 45...66 Hz +/- 10 %; 90...120 V AC 400 Hz +/- 10 %; 110...480 V DC +/- 10 %
Network frequency50 Hz; 60 Hz
Ride-through time100 ms 6 cycles at 60 Hz 120 V AC typical; 400 ms 24 cycles at 60 Hz 240 V AC typical; 1200 ms 72 cycles at 60 Hz 480 V AC typical
[In] rated current1 A; 5 A
type of network3P + N + E
Power consumption in VA38 VA at 480 V AC
Maximum power consumption in VA80 VA at 480 V AC
Display typeWithout display
Sampling rate1024 samples/cycle
Measurement current0.01…20 A
input typeVoltage (impedance 5 MOhm); External CT (impedance 0.3 mOhm)5 x
Measurement voltage57…400 V AC 42...69 Hz between phase and neutral; 100…690 V AC 42...69 Hz between phases; 10 kV AC transient
Frequency measurement range20…450 Hz
Number of inputs8 digital 30 V AC/60 V DC
Measurement accuracyVoltage +/- 0.1 %; Current +/- 0.1 %
Accuracy classClass 0.1S active energy conforming to IEC 62053-22; Class 0.1 active energy conforming to IEC 61557-12; Class 0.1 active energy conforming to ANSI C12.20; Class 0.5S reactive energy conforming to IEC 62053-24; Class 0.1 current conforming to IEC 61557-12; Class 0.1 voltage conforming to IEC 61557-12; Class 0.1 active power conforming to IEC 61557-12; Class 0.5 power factor conforming to IEC 61557-12
Number of outputs4 digital; 2 form C relay
Communication port protocolModbus RTU at 2400...115200 bps - 2-wire; ION at 2400...115200 bps - 2-wire; DNP3 at 2400...115200 bps - 2-wire; Modbus TCP at 10/100 Mbit/s; ION TCP at 10/100 Mbit/s; DNP3 TCP at 10/100 Mbit/s; IEC 61850; Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s; DHCP; DNS; DLMS
Communication port supportRS485 2 removable screw terminal block
Port Ethernet10/100BASE-TX 2 RJ45
Communication gatewayEthernet/serial
Time synchronisation protocolGPS; IRIG-B; NTP; SNTP; PTP
Data recordingTime stamping; Min/max of instantaneous values; User-definable data logs; Continuous logging or snapshot; Trending/forecasting; Event logs; Alarm logs; Configuration change; Power outage; User login/logout; Data logs; GPS synchronisation; Sequence of event recording
Memory capacity2 GB
CybersecuritySyslog protocol support; Robust security logs; Port hardening; Enable/disable communication ports; Hardware metrology lock
Web servicesViewing of captured waveform; Web page; Pass/fail report for IEEE 519; Pass/fail report for EN 50160; ITIC (CBEMA) curve; SEMI curve; NEMA motor derating curve; Alarm notification by e-mail; TLS 1.2; Push historical data via mail
Ethernet serviceDHCP client; Device Profile Web Services (DPWS); Rapid Scanning Tree Protocol (RSTP); FTP/HTTP/HTTPS
Communication serviceCompliant reports; Power quality summary; Energy report; EcoStruxure Power Events Analysis; SMTP e-mail notification; SNMP
Tamperproof of settingsProtected by sealable cover
Mounting supportDIN rail
Electrical insulation classClass III conforming to EN/IEC 62052-11
Isolation voltageIII400…690 V conforming to EN 61010-1:ed. 3; III347…600 V conforming to UL 61010-1:ed. 3; III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
Width160 mm
Depth135.3 mm
Height160 mm
Net weight1.5 kg
Market segmentData center; Healthcare; Semiconductor; Pharmaceutical; Chemical; Energy; Mining
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP65 front: ; IP30 rear:
Degree of protectionUL type 12, front
Relative humidity5…95 %
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Installation categoryIII
Operating altitude0...3000 m
StandardsANSI C12.20; ANSI C37.90.1; IEC 61000-4-15; IEC 61000-4-30; IEC 61010-1; IEC 61326-1; IEC 61557-12; IEC 61850; IEC 62052-11; IEC 62052-31; IEC 62053-22; IEC 62053-23; IEC 62053-24; IEC 62586; UL 61010-1
Quality labelsISO 9001; ISO 14000
Main
RangePowerLogic
Product or component typeEnergy and power quality meter
Device short nameION95030
Product namePowerLogic ION9000
Device applicationPower monitoring; WAGES metering; Net metering; Medium voltage; High voltage
Metering typeDemand current I1, I2, I3, I4, I5; Peak demand currents; Demand power P, Q, S; Peak demand power PM, QM, SM; Calculated active and reactive energy (+/- W.h, +/- VAR.h)
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height29.5 cm
Package 1 Width26.4 cm
Package 1 Length37.8 cm
Package 1 Weight2.5 kg
Unit Type of Package 2P06
Number of Units in Package 28
Package 2 Height45.0 cm
Package 2 Width80.0 cm
Package 2 Length60.0 cm
Package 2 Weight32.028 kg
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/998835
qrcode für Schneider Electric METSEION95030 power analyzer ION9000T