Additional features
Device applicationRevenue settlement; S0 pulse recording for measurement of water, air, gas, electricity, steam; Data aggregation; Power monitoring
Measured value typeCurrent; total voltage; total frequency; total active and reactive power; total apparent power; total power factor; active and reactive power per phase, RMS; apparent power per phase, RMS; power factor per phase, RMS; active and reactive energy; total apparent energy
Supply voltage20 - 60 V DC ± 10 %
Network frequency50 Hz; 60 Hz
[In] Rated current10 A; 1 A; 5 A
Pole description1P + N; 3P; 3P + N
Power consumption in W17 W
Display typeWithout display
Scanning interval512 samples/cycle
Measurement current50…10000 mA
Analogue input typeVoltage (impedance 5 MOhm); current (impedance 0.3 mOhm)
Measuring voltage57…400 V AC 42 - 69 Hz between phase and neutral; 100…690 V AC 42 - 69 Hz between phases
Measuring range for frequency42…69 Hz
Number of inputs3 digital 30 V AC; 3 digital 60 V DC
Accuracy of measurementCurrent ± 0.1 %; Voltage ± 0.1 %; Active energy ± 0.2 %
Accuracy classClass 0.2S active energy corresponds to IEC 62053-22; Class 0.2 active energy corresponds to ANSI C12.20; Class 0.2 active power corresponds to IEC 61557-12; Class 0.5S reactive energy corresponds to IEC 62053-24; Class 0.5 power factor corresponds to IEC 61557-12; Class 0.2 voltage corresponds to IEC 61557-12; Class 0.2 current corresponds to IEC 61557-12; Class 0.2 frequency corresponds to IEC 61557-12; Class 0.2 active energy corresponds to IEC 61557-12
Number of outputs1 impulse
Displayed informationVoltage; current; frequency; power; energy consumption; harmonic distortion
Communications protocolModbus RTU at 115 kBaud - 2-wire; ION at 115 kBaud - 2-wire; DNP3; IEC 61850; Modbus TCP/IP; Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s; RSTP 801.1d 2004; DLMS
Support for communication interfacesEthernet; Screw terminal block: RS485; Mini-B-USB: USB
Communication network typeIPv6 (Internet protocol)
Data loggingSequence of event recording; trend curves/forecasts; harmonic logs; timestamping; GPS synchronization; waveform logs; minimum/maximum values of real-time values; voltage dip and overvoltage capture; data logs; event recording; alarm logs; 64 data loggers
Memory capacity512 MB
Web servicesCustomizable homepage; uploading/downloading files via FTP; uploading/downloading files via SFTP; web server; alarm notification by email; display of captured waveform (FTP); display of captured waveform (web); HTTPS server
Communication serviceNTP time synchronization; E-mail notification via SMTP; RSTP support; DHCP; SNMP; PTP time synchronization
CybersecurityActivation/deactivation of communication ports; robust security protocols; hardening; password protection; Syslog logging support
Mounting modePlug-in
Mounting bracketDIN rail
Installation typeIndoor installation
Installation categoryIII
Safety designIII400…690 V complies with IEC 61010-1:Ed. 3; III400…690 V complies with EN 61010-1:Ed. 3; III347…600 V complies with UL 61010-1:Ed. 3; III347…600 V complies with CSA C22.2 No. 61010-1:Ed. 3
StandardsIEC 61326-1; IEC 62053-22; IEC 62053-24; IEC 62052-11; IEC 61557-12; IEEE 1588; IEC 62586
Product certificationsCE; CULus; N998
Width90,5 mm
Depth90,8 mm
Height90,5 mm
Product weight528 g
Contractual warranty
Warranty (in months)18
Main features
Product seriesPowerLogic
Product namePowerLogic ION7400
Product or component typePower meter
Device short nameION7413
Model typeExtended
Mounting
Degree of protection (IP)IP30 corresponds to IEC 60529
Relative humidity5…95 %
Operating ambient temperature-25…70 °C
Ambient temperature during storage-40…85 °C
Operating altitude3.000 m
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height14,0 cm
VPE 1 width14,0 cm
VPE 1 length18,5 cm
Packaging weight (Lbs)854 g
VPE 2 typeS03
VPE 2 quantity8
VPE 2 height30 cm
VPE 2 width30 cm
VPE 2 length40 cm
VPE 2 weight7,386 kg
Die PowerLogic ION7413A Netzanalysatoren werden in einem Formfaktor für die DIN-Schienenmontage und DC Steuerspannung geliefert. Es wurde entwickelt, um Ihnen ein besseres Verständnis der Betriebsabläufe und mehr Effizienz für Ihre Versorgungsnetzanwendungen in Umspannwerken zu ermöglichen. Es ermöglicht Energietransparenz und liefert verwertbare Daten aus komplexen Netzqualitätsbedingungen. Mit seiner modularen, flexiblen und leistungsstarken ION-Technologie können Sie für jeden Netzanalysator individuelle Anwendungen erstellen. Es verfügt über eine Genauigkeit auf Einnahmenebene, Berichte zur Spannungsqualität, mehrere Kommunikationsanschlüsse und ein farbiges Grafikdisplay. Messung der Netzqualität durch Erfassung der harmonischen Verzerrungen von Strom und Spannung sowie der einzelnen Oberschwingungen - über Anzeige oder Weboberfläche bis zur 63. Ordnung und über EcoStruxure Software bis zur 127. Ordnung. Von unabhängigen Prüflaboren zertifiziert für Energiegenauigkeit (IEC 62052-22, IEC 62052-24). Zertifiziert auch für Netzqualität der Klasse A (IEC61000-4-30, IEC62586-2). Zu den Cybersecurity Funktionen gehören sichere Protokolle (HTTPS, SFTP, Secure ION), die Protokollierung von Sicherheitsereignissen sowie das Syslog Protokoll. Möglichkeit zum Aktivieren/Deaktivieren von Kommunikationsports sowie Unterstützung von 50 konfigurierbaren Benutzerkonten zur Verwaltung des Zugriffs. Mit 512¿MB Speicher zur Unterstützung von bis zu 64 Datenlogs (1024 Kanäle), über 50 benutzerdefinierten Alarmen, Wellenformerfassung, 512 Samples pro Zyklus bzw. Abtastrate. Der Speicher kann auch für benutzerdefinierte Webseiten, Min-/Max-Protokolle, Energietrends und Nutzungszeiten verwendet werden. Die Möglichkeit, Ereignisse mithilfe von Zeitsynchronisation mit einer Genauigkeit von +/-1 ms zu zeitstempeln. Zeitsynchronisationsmethode, die PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) und Netzwerk-Zeiteinstellungsfunktion umfasst. 3 digitale Eingänge und ein digitaler Ausgang sowie die Möglichkeit, bis zu 4 Optionsmodule hinzuzufügen. Die E/A-Optionsmodule umfassen 2 Relais und 6 digitale Eingänge oder 2 analoge Ausgänge und 4 analoge Eingänge. Breiter Regelbereich von 20-60 VDC. Betriebsumgebung von -25 bis +70 °C, Luftfeuchtigkeit von 5 % bis 95 %, Höhe bis zu 3000 m.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/2489880
qrcode für Schneider Electric METSEION7413A power analyzer ION Class A