| Additional features |
| Device application | Revenue settlement; S0 pulse recording for measurement of water, air, gas, electricity, steam; Data aggregation; Power monitoring |
| Measured value type | Current; total voltage; total frequency; total active and reactive power; total apparent power; total power factor; active and reactive power per phase, RMS; apparent power per phase, RMS; power factor per phase, RMS; active and reactive energy; total apparent energy |
| Supply voltage | 20 - 60 V DC ± 10 % |
| Network frequency | 50 Hz; 60 Hz |
| [In] Rated current | 10 A; 1 A; 5 A |
| Pole description | 1P + N; 3P; 3P + N |
| Power consumption in W | 17 W |
| Display type | Without display |
| Scanning interval | 512 samples/cycle |
| Measurement current | 50…10000 mA |
| Analogue input type | Voltage (impedance 5 MOhm); current (impedance 0.3 mOhm) |
| Measuring voltage | 57…400 V AC 42 - 69 Hz between phase and neutral; 100…690 V AC 42 - 69 Hz between phases |
| Measuring range for frequency | 42…69 Hz |
| Number of inputs | 3 digital 30 V AC; 3 digital 60 V DC |
| Accuracy of measurement | Current ± 0.1 %; Voltage ± 0.1 %; Active energy ± 0.2 % |
| Accuracy class | Class 0.2S active energy corresponds to IEC 62053-22; Class 0.2 active energy corresponds to ANSI C12.20; Class 0.2 active power corresponds to IEC 61557-12; Class 0.5S reactive energy corresponds to IEC 62053-24; Class 0.5 power factor corresponds to IEC 61557-12; Class 0.2 voltage corresponds to IEC 61557-12; Class 0.2 current corresponds to IEC 61557-12; Class 0.2 frequency corresponds to IEC 61557-12; Class 0.2 active energy corresponds to IEC 61557-12 |
| Number of outputs | 1 impulse |
| Displayed information | Voltage; current; frequency; power; energy consumption; harmonic distortion |
| Communications protocol | Modbus RTU at 115 kBaud - 2-wire; ION at 115 kBaud - 2-wire; DNP3; IEC 61850; Modbus TCP/IP; Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s; RSTP 801.1d 2004; DLMS |
| Support for communication interfaces | Ethernet; Screw terminal block: RS485; Mini-B-USB: USB |
| Communication network type | IPv6 (Internet protocol) |
| Data logging | Sequence of event recording; trend curves/forecasts; harmonic logs; timestamping; GPS synchronization; waveform logs; minimum/maximum values of real-time values; voltage dip and overvoltage capture; data logs; event recording; alarm logs; 64 data loggers |
| Memory capacity | 512 MB |
| Web services | Customizable homepage; uploading/downloading files via FTP; uploading/downloading files via SFTP; web server; alarm notification by email; display of captured waveform (FTP); display of captured waveform (web); HTTPS server |
| Communication service | NTP time synchronization; E-mail notification via SMTP; RSTP support; DHCP; SNMP; PTP time synchronization |
| Cybersecurity | Activation/deactivation of communication ports; robust security protocols; hardening; password protection; Syslog logging support |
| Mounting mode | Plug-in |
| Mounting bracket | DIN rail |
| Installation type | Indoor installation |
| Installation category | III |
| Safety design | III400…690 V complies with IEC 61010-1:Ed. 3; III400…690 V complies with EN 61010-1:Ed. 3; III347…600 V complies with UL 61010-1:Ed. 3; III347…600 V complies with CSA C22.2 No. 61010-1:Ed. 3 |
| Standards | IEC 61326-1; IEC 62053-22; IEC 62053-24; IEC 62052-11; IEC 61557-12; IEEE 1588; IEC 62586 |
| Product certifications | CE; CULus; N998 |
| Width | 90,5 mm |
| Depth | 90,8 mm |
| Height | 90,5 mm |
| Product weight | 528 g |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | PowerLogic |
| Product name | PowerLogic ION7400 |
| Product or component type | Power meter |
| Device short name | ION7413 |
| Model type | Extended |
| Mounting |
| Degree of protection (IP) | IP30 corresponds to IEC 60529 |
| Relative humidity | 5…95 % |
| Operating ambient temperature | -25…70 °C |
| Ambient temperature during storage | -40…85 °C |
| Operating altitude | 3.000 m |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 14,0 cm |
| VPE 1 width | 14,0 cm |
| VPE 1 length | 18,5 cm |
| Packaging weight (Lbs) | 854 g |
| VPE 2 type | S03 |
| VPE 2 quantity | 8 |
| VPE 2 height | 30 cm |
| VPE 2 width | 30 cm |
| VPE 2 length | 40 cm |
| VPE 2 weight | 7,386 kg |
Die PowerLogic ION7413A Netzanalysatoren werden in einem Formfaktor für die DIN-Schienenmontage und DC Steuerspannung geliefert. Es wurde entwickelt, um Ihnen ein besseres Verständnis der Betriebsabläufe und mehr Effizienz für Ihre Versorgungsnetzanwendungen in Umspannwerken zu ermöglichen. Es ermöglicht Energietransparenz und liefert verwertbare Daten aus komplexen Netzqualitätsbedingungen. Mit seiner modularen, flexiblen und leistungsstarken ION-Technologie können Sie für jeden Netzanalysator individuelle Anwendungen erstellen. Es verfügt über eine Genauigkeit auf Einnahmenebene, Berichte zur Spannungsqualität, mehrere Kommunikationsanschlüsse und ein farbiges Grafikdisplay. Messung der Netzqualität durch Erfassung der harmonischen Verzerrungen von Strom und Spannung sowie der einzelnen Oberschwingungen - über Anzeige oder Weboberfläche bis zur 63. Ordnung und über EcoStruxure Software bis zur 127. Ordnung. Von unabhängigen Prüflaboren zertifiziert für Energiegenauigkeit (IEC 62052-22, IEC 62052-24). Zertifiziert auch für Netzqualität der Klasse A (IEC61000-4-30, IEC62586-2). Zu den Cybersecurity Funktionen gehören sichere Protokolle (HTTPS, SFTP, Secure ION), die Protokollierung von Sicherheitsereignissen sowie das Syslog Protokoll. Möglichkeit zum Aktivieren/Deaktivieren von Kommunikationsports sowie Unterstützung von 50 konfigurierbaren Benutzerkonten zur Verwaltung des Zugriffs. Mit 512¿MB Speicher zur Unterstützung von bis zu 64 Datenlogs (1024 Kanäle), über 50 benutzerdefinierten Alarmen, Wellenformerfassung, 512 Samples pro Zyklus bzw. Abtastrate. Der Speicher kann auch für benutzerdefinierte Webseiten, Min-/Max-Protokolle, Energietrends und Nutzungszeiten verwendet werden. Die Möglichkeit, Ereignisse mithilfe von Zeitsynchronisation mit einer Genauigkeit von +/-1 ms zu zeitstempeln. Zeitsynchronisationsmethode, die PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) und Netzwerk-Zeiteinstellungsfunktion umfasst. 3 digitale Eingänge und ein digitaler Ausgang sowie die Möglichkeit, bis zu 4 Optionsmodule hinzuzufügen. Die E/A-Optionsmodule umfassen 2 Relais und 6 digitale Eingänge oder 2 analoge Ausgänge und 4 analoge Eingänge. Breiter Regelbereich von 20-60 VDC. Betriebsumgebung von -25 bis +70 °C, Luftfeuchtigkeit von 5 % bis 95 %, Höhe bis zu 3000 m.