| Complementary |
| Poles description | 3P + N; 1P + N; 3P |
| Type of measurement | Active energy total; Active energy per phase; Active energy partial |
| Metering type | Active energy (signed, two quadrant) |
| Device application | Partial meter; Sub billing |
| Accuracy class | Class 1 active energy conforming to IEC 62053-21 |
| input type | Direct connection |
| [In] rated current | 125 A |
| Rated voltage | 100…277 V; 173…480 V |
| Network frequency | 60 Hz; 50 Hz |
| Technology type | Electronic |
| Display type | LCD display |
| Sampling rate | 32 samples/cycle |
| Measurement current | 0…125 A |
| Maximum value measured | 99999999.9 kWh |
| Communication port protocol | Modbus RTU at 9.6, 19.2 and 38.4 kbauds even/odd or none, insulation 4000 V |
| Communication port support | Screw terminal block: RS485 |
| Local signalling | Green indicator light: power ON; Yellow flashing LED: accuracy checking; Yellow indicator light: communications are active on the Modbus port (Modbus) |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| Connections - terminals | Current circuit: screw terminals 50 mm² cable(s) |
| Overvoltage category | III |
| Standards | BS EN 61557-12:2021; IEC 61557-12:2021; EN 61557-12:2021; BS EN 61326-1; IEC 61326-1; EN 61326-1; BS EN 62052-11:2020; IEC 62052-11:2020; EN 62052-11:2020; BS EN 62053-21; IEC 62053-21; EN 62053-21; BS EN 62052-31:2015; IEC 62052-31:2015; EN 62052-31:2015; BS EN 61010-1:2010; EN 61010-1:2010; IEC 61010-1:2010; UL 61010-1:2010; BS EN 61010-2-30; IEC 61010-2-30; EN 61010-2-30; UL 61010-2-30; BS EN 50470-3; EN 50470-3; BS EN 50470-1; EN 50470-1; ANSI C12.16 |
| Product certifications | CE conforming to IEC 61010-1 (safety); CE conforming to EN 61557-12 (power monitor); CE conforming to EN/IEC 61326-1 (EMC); UKCA conforming to BS EN 61010-1 (safety); UKCA conforming to BS EN 61557-12 (power monitor); UKCA conforming to BS EN 61326-1 (EMC); CULus conforming to UL 61010-1 (safety); CULus conforming to EN 61010-1 (safety); MID conforming to EN 50470-1 (sub-meter); MID conforming to EN 50470-3 (sub-meter) |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| IP degree of protection | IP40 front panel: conforming to IEC 60529; IP20 body: conforming to IEC 60529 |
| Pollution degree | 2 |
| Relative humidity | 5…95 % at 50 °C |
| Ambient air temperature for operation | -25…70 °C - MID; -25…70 °C - IEC |
| Ambient air temperature for storage | -40…85 °C |
| Operating altitude | < 2000 m |
| Colour | White |
| 9 mm pitches | 14 |
| Width | 126 mm |
| Height | 103.2 mm |
| Depth | 69.3 mm |
| Main |
| Range | PowerLogic |
| range of product | PowerLogic EM3000 |
| Product or component type | Energy meter |
| Device short name | EM3424 |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.500 cm |
| Package 1 Width | 11.000 cm |
| Package 1 Length | 13.200 cm |
| Package 1 Weight | 676.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 11.190 kg |
Die PowerLogic EM3000-Serie umfasst eine Reihe von dreiphasigen, auf DIN-Schienen montierten Energiezählern mit hinterleuchtetem LCD-Display. Messung von Wirkenergie und Wirkleistung. Die Versorgungsspannung kann in Netzen mit 50 Hz oder 60 Hz zwischen 100 und 277 VAC oder zwischen 173 und 480 VAC liegen. Der Bemessungsstrom der Leitung für dieses Messgerät beträgt bis zu 125 A. Das Messgerät liefert die folgenden Genauigkeiten, Wirkenergieklasse 1 nach IEC62053-21, IEC61557-12 und Klasse B nach EN50470-3. Das Kommunikationsprotokoll ist Modbus RTU. Dieses Messgerät kann für Teilabrechnungs- und Teilzählungsanwendungen eingesetzt werden. Die Produktabmessungen sind wie folgt: Breite 126 mm, Tiefe 69 mm, Höhe 103 mm und Produktgewicht 590,2 g. Zur zusätzlichen lokalen Signalisierung gehören eine grüne LED-Betriebsanzeige, eine blinkende gelbe LED für die Genauigkeitsprüfung und Kommunikationsanzeigen. Zu den Zertifizierungen gehören CE, UL und MID. Das Messgerät kann in einphasigen und neutralen (1P+N), dreiphasigen (3P) und dreiphasigen und neutralen (3P+N) Netzen installiert werden. Kompatibel mit Energiemanagementsoftware zur Nutzung der Vorteile der digitalen IoT-Energieverteilung.