Further information for Schneider Electric M9D11606 circuit breaker 1-pole+N 6A
Complementary
Network frequency
50 Hz
[Ue] rated operational voltage
240 V AC 50 Hz
Magnetic tripping limit
8.5 x In +/- 20 % AC
Residual current tripping technology
Voltage independent
[Ics] rated service breaking capacity
4.5 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50 Hz
[Ui] rated insulation voltage
400 V AC 50 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 60947-2
Surge current
250 A
Control type
Toggle
Local signalling
ON/OFF indication; Fault indication
Mounting mode
Clip-on
Mounting support
DIN rail
Connection pitch
9 mm between phase and neutral
9 mm pitches
4
Height
81 mm
Width
36 mm
Depth
70 mm
Net weight
0.125 kg
Colour
Grey
Mechanical durability
20000 cycles
Electrical durability
20000 cycles
Provision for padlocking
Padlockable
Connections - terminals
Tunnel type terminal (top or bottom)0.75…16 mm² - rigid; Tunnel type terminal (top or bottom)0.33…10 mm² - flexible; Tunnel type terminal (top or bottom)0.33…10 mm² - flexible with ferrule
Wire stripping length
13 mm for top or bottom connection
Tightening torque
2 N.m top or bottom
Earth-leakage protection
Integrated
Contact position indicator
Contractual warranty
Warranty (in months)
18
Environment
IP degree of protection
IP20 conforming to IEC 60529; IP40 (modular enclosure) conforming to IEC 60529
Pollution degree
3 conforming to EN/IEC 60947-2
Overvoltage category
IV
Electromagnetic compatibility
8/20 µs impulse withstand, 250 A
Tropicalisation
2 conforming to IEC 60068-1
Relative humidity
95 % at 55 °C
Ambient air temperature for operation
-5…60 °C
Ambient air temperature for storage
-30…70 °C
Logistical informations
Country of origin
ES
Main
Range
Multi9
Product name
Multi9 N40 Vigi
Product or component type
Residual current breaker with overcurrent protection (RCBO)
Device short name
N40 Vigi
Device application
Distribution
Poles description
1P + N
Neutral position
Left
Number of protected poles
1
[In] rated current
6 A at 50 °C conforming to EN/IEC 60947-2
Network type
AC
Trip unit technology
Thermal-magnetic
Curve code
C
Earth-leakage sensitivity
30 mA
Earth-leakage protection time delay
Instantaneous
Earth-leakage protection class
Type AC
Breaking capacity
6 kA Icu at 240 V AC 50 Hz conforming to EN/IEC 60947-2
Utilisation category
Category A conforming to EN/IEC 60947-2
Suitability for isolation
Yes conforming to EN/IEC 60947-2
Standards
EN/IEC 60947-2
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
4.000 cm
Package 1 Width
8.200 cm
Package 1 Length
11.000 cm
Package 1 Weight
201.000 g
Unit Type of Package 2
S03
Number of Units in Package 2
54
Package 2 Height
30.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
11.261 kg
FI/LS switch Multi 9 OEM, N40 Vigi, 6kA (IEC/EN 61009-1). 1-pole+N, nominal current 6A, C characteristic, nominal residual current 30 mA, operating voltage (Ue) 240V AC, insulation voltage (Ui) 400V AC. Fastened using a normal clip fastener on a DIN rail. Snap action for low-wear switching of the contacts. Test button - for regular function testing. FI/LS switch N40 Vigi for protecting people in the event of direct contact, systems against fire hazards, overloads and short circuits and for switching and disconnecting circuits. Technology of the trip unit - thermomagnetic. Additional auxiliary modules that can be connected in series (optional) - display of switch position (OF), fault tripping (SD), shunt release (MX, MX+OF), undervoltage release (MN, MNs, MNx). Tool-free installation on the left side of the device. The N40 Vigi complies with the following standards - IEC/EN 61009-1.