Schneider Electric LV516342, EAN: 3606480229282

Schneider Electric LV516342 power circuit breaker 4P 36 kA

Schneider Electric LV516342 power circuit breaker 4P 36 kA

Lieske Part No. 921129
Mfg Part No LV516342
EAN-Code 3606480229282
Manufacturer Schneider Electric
Here only 615,02 EUR
731,87 EUR incl. VAT

Further information for Schneider Electric LV516342 power circuit breaker 4P 36 kA

Additional features
[Uimp] Rated impulse voltage withstand8 kV corresponds to EN/IEC 60947-2
Network frequency50/60 Hz
Breaking capacityF
[Ics] Rated operational breaking capacity18 kA at 440 V AC 50/60 Hz according to IEC 60947-2; 36 kA at 380/415 V AC 50/60 Hz according to IEC 60947-2; 70 kA at 220/240 V AC 50/60 Hz according to IEC 60947-2
Neutral positionLeft
Mechanical life25000 cycles
Electrical lifetime12000 cycles 415 V In corresponds to IEC 60947-2
Control typeToggle switch
Adjustable range for thermal protection87,5…125 A
Neutral conductor protection settingNo protection (3D)
[Ir] type of long-time pickup settingAdjustable
Adjustment range for long exposure0,7 - 1 x In
Type of long-time delay settingFixed
[Ii] type of instantaneous short-circuit settingFixed
Adjustment range of instantaneous short circuit1.250 A
Mounting bracketRear panel
Mounting modeFixed
Connection on top sidefront side
Connection on undersidefront side
Connections - terminalsScrewed connection
Terminal pitch35 mm
Compatibility codeCVS160
Width140 mm
Depth86 mm
Height161 mm
Product weight1,9 kg
Contact position indicatorJa
Contractual warranty
Warranty (in months)18
Main features
Product seriesEasyPacT
Product nameEasyPacT CVS
Device short nameCVS160F
Product or component typePower-cut-out switch
Device applicationDistribution
Pole description4P
Description of protected poles3D
Earth fault protection (Vigi Add On)None
[In] Rated current125 A at 40 °C
Type of networkAC
Application categoryCategory A
Rated ultimate short-circuit breaking capacity [Icu]36 kA Icu at 440 V AC 50/60 Hz, complies with IEC 60947-2; 36 kA Icu at 380/415 V AC 50/60 Hz, complies with IEC 60947-2; 70 kA Icu at 220/240 V AC 50/60 Hz, complies with IEC 60947-2
Trigger nameTM-D
Trigger technologyThermal-magnetic
Trigger power125 A at 40 °C
Degree of protectionOverload protection (thermal); short-circuit protection (magnetic)
Mounting
StandardsIEC 60947-2; EN 60947-2
Product certificationsIEC; GOST
Protection class for electric shocksClass II
Pollution degree3 entspricht IEC 60664-1
Degree of protection (IP)IP40
Operating ambient temperature-25…70 °C
Ambient temperature during storage-50…85 °C
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height14,000 cm
VPE 1 width15,000 cm
VPE 1 length19,000 cm
Packaging weight (Lbs)2,600 kg
VPE 2 typeS03
VPE 2 quantity4
VPE 2 height30,000 cm
VPE 2 width30,000 cm
VPE 2 length40,000 cm
VPE 2 weight11,200 kg