Schneider Electric LV480902, EAN: 3606480796081

Schneider Electric LV480902 series terminal block 1-pole

Industrial Material > Connection technology > Terminals

Schneider Electric LV480902 series terminal block 1-pole

Lieske Part No. 1868754
Mfg Part No LV480902
EAN-Code 3606480796081
Manufacturer Schneider Electric
Here only 241,50 EUR
287,39 EUR incl. VAT

Further information for Schneider Electric LV480902 series terminal block 1-pole

Complementary
Breaking capacity120 kA at 415 V (AC); 120 kA at 500 V (AC); 120 kA at 690 V (AC)
[Icw] rated short-time withstand current15 kA for 1 s
[Im] rated making and breaking capacity30 kA at 690 V
Rated dutyUninterrupted
Control typeFuse carriers handle
Provision for padlocking3 padlocks
Mounting positionVertical
Mounting modeFixed
Mounting supportBusbars
Mounting locationOne above the other
Contact operationSingle-break
Mechanical durability800 cycles
Electrical durabilityAC-21B: 200 cycles 690 V AC 50/60 Hz; AC-22B: 200 cycles 500 V AC 50/60 Hz; AC-23B: 200 cycles 415 V AC 50/60 Hz
Connections - terminalsScrew connection downstream M12 400 A; Direct connection upstream 400 A 185 mm
Tightening torque32 N.m
Width100 mm
Height741 mm
Depth190 mm
Net weight5 kg
StandardsEN/IEC 60947-1; EN/IEC 60947-3
Product certificationsCE; CCC
Contractual warranty
Warranty (in months)18
Environment
Electrical shock protection classClass II front face
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Ambient air temperature for operation-20…70 °C
Ambient air temperature for storage-50…85 °C
Main
RangeFuPacT
Product nameFuPacT ISFL
Device short nameISFL400
Product or component typeFuse-switch disconnector
Device applicationEquipment protection, monitoring and control; Distribution
Signalling functionSeparated fuse monitor
Poles description3 x 1P switchable
Number of fuse carriers3
Fuse typeDIN
Fuse sizeNH2
Suitability for isolationYes conforming to EN/IEC 60947-3
[Ith] conventional free air thermal current400 A ( 40 °C ) power dissipation per fuse: 34 W
[Ithe] conventional enclosed thermal current400 A at 40 °C, Power dissipation per fuse: 34 W
Maximum power dissipation per pole53 W
[Ue] rated operational voltage690 V AC 50/60 Hz; 800 V AC 50/60 Hz AC-20; 800 V DC DC-20
[Ui] rated insulation voltage1000 V AC 50/60 Hz; 1000 V DC
[Uimp] rated impulse withstand voltage8 kV
[Ie] rated operational currentAC-21B: 400 A at 220/240 V AC 50/60 Hz; AC-21B: 400 A at 380/415 V AC 50/60 Hz; AC-21B: 400 A at 440/480 V AC 50/60 Hz; AC-21B: 400 A at 500 V AC 50/60 Hz; AC-21B: 400 A at 660/690 V AC 50/60 Hz; AC-21B: 250 A at 800 V AC 50/60 Hz; AC-22B: 400 A at 220/240 V AC 50/60 Hz; AC-22B: 400 A at 380/415 V AC 50/60 Hz; AC-22B: 400 A at 440/480 V AC 50/60 Hz; AC-22B: 400 A at 500 V AC 50/60 Hz; AC-23B: 400 A at 220/240 V AC 50/60 Hz; AC-23B: 400 A at 380/415 V AC 50/60 Hz
Visible breakYes
Contact position indicatorYes
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.4 cm
Package 1 Width21.6 cm
Package 1 Length78.7 cm
Package 1 Weight6.0 kg
Unit Type of Package 2P12
Number of Units in Package 250
Package 2 Height117.0 cm
Package 2 Width80.0 cm
Package 2 Length120.0 cm
Package 2 Weight312.0 kg
ISFL400A - 185 mm busbar, single-pole switchable with M12 screws.