| Complementary |
| Network type | AC |
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 200...440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Earth-leakage protection | With |
| Maximum breaking time | 800 ms |
| Overvoltage category | IV |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Electrical shock protection class | Class II |
| Standards | IEC 60947-2 |
| Logistical informations |
| Country of origin | IT |
| Main |
| Range of product | ComPacT NSX100...250; ComPact NSX100...250 |
| Device short name | VigiPacT |
| Product or component type | Vigi add-on |
| Device application | Wiring |
| Range compatibility | ComPacT ComPacT NSX100 circuit breaker; ComPacT ComPacT NSX160 circuit breaker; ComPact ComPact NSX100 circuit breaker; ComPact ComPact NSX160 circuit breaker |
| Poles description | 3P |
| [In] rated current | 100 A; 160 A |
| Earth-leakage protection class | Class A; Class AC |
| Residual earth-leakage sensitity adjustment type | Adjustable |
| Earth-leakage sensitivity | 0.03 A for class A; 0.1 A for class A; 0.3 A for class A; 0.5 A for class A; 1 A for class A; 3 A for class A; 10 A for class AC; 30 A for class AC |
| Residual earth-leakage time delay adjustment type | Adjustable |
| [Δt] residual earth-leakage time delay adjustment | 0 ms; 60 ms; 150 ms; 300 ms; 500 ms; 800 ms; 1.2 s; 4 s |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 13.000 cm |
| Package 1 Width | 14.500 cm |
| Package 1 Length | 17.000 cm |
| Package 1 Weight | 1.083 kg |
| Unit Type of Package 2 | S04 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 40.000 cm |
| Package 2 Length | 60.000 cm |
| Package 2 Weight | 13.440 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 48 |
| Package 3 Height | 42.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 65.984 kg |
This is a Vigi add-on module for ComPact NSX 100/160 that provides residual current protection. It is used for 3-pole circuit breakers. The operating voltage is between 200 and 440 VAC 50/60 Hz. The differential current sensitivity is adjustable from 30 mA to 30 A. It is plugged directly onto the device connection terminals and directly activates the release in the event of a fault due to residual current. This Vigi add-on module is internally powered by the voltage of the distribution network, even if it is only powered by 2 phases. It complies with the IEC 60947-2 standard, Annex B.