| Complementary |
| Control circuit voltage limits | 20...26.5 V for AC circuit 24 V in operation; 14.5 V for AC circuit 24 V drop-out |
| Typical current consumption | 140 mA at 24 V AC I maximum while closing with LUB12; 220 mA at 24 V AC I maximum while closing with LUB32; 220 mA at 24 V AC I maximum while closing with LUB38; 70 mA at 24 V AC I rms sealed with LUB12; 90 mA at 24 V AC I rms sealed with LUB32; 90 mA at 24 V AC I rms sealed with LUB38 |
| Heat dissipation | 2 W for control circuit with LUB12; 3 W for control circuit with LUB32; 3 W for control circuit with LUB38 |
| Operating time | 35 ms opening with LUB12 for control circuit; 35 ms opening with LUB32 for control circuit; 35 ms opening with LUB38 for control circuit; 70 ms closing with LUB12 for control circuit; 70 ms closing with LUB32 for control circuit; 70 ms closing with LUB38 for control circuit |
| Reset | Manual reset |
| Standards | EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier |
| Product certifications | CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-6-2; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-6-2 |
| Safe separation of circuit | 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 |
| Fixing mode | Plug-in (front face) |
| Width | 45 mm |
| Height | 66 mm |
| Depth | 60 mm |
| Compatibility code | LUCC |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| IP degree of protection | IP20 front panel and wired terminals conforming to IEC 60947-1; IP20 other faces conforming to IEC 60947-1; IP40 front panel outside connection zone conforming to IEC 60947-1 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Operating altitude | 2000 m |
| Fire resistance | 960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12 |
| Shock resistance | 10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27 |
| Vibration resistance | 2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6; 4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6 |
| Resistance to electrostatic discharge | 8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2 |
| Non-dissipating shock wave | 1 kV serial mode conforming to IEC 60947-6-2; 2 kV common mode conforming to IEC 60947-6-2 |
| Resistance to radiated fields | 10 V/m 3 conforming to IEC 61000-4-3 |
| Resistance to fast transients | 2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 |
| Immunity to radioelectric fields | 10 V conforming to IEC 61000-4-6 |
| Immunity to microbreaks | 3 ms |
| Immunity to voltage dips | 70 % / 500 ms conforming to IEC 61000-4-11 |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys |
| Range of product | TeSys Ultra |
| Product name | TeSys Ultra |
| Device short name | LUCC |
| Product or component type | Advanced control unit |
| Device application | Motor control; Motor protection |
| Product specific application | Basic protection and advanced functions, communication |
| main function available | Manual reset; Protection against overload and short-circuit; Protection against phase failure and phase imbalance; Earth fault protection |
| Product compatibility | Power base LUB12; Power base LUB32; Power base LUB38; Power base LUB120; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B12B; Reversing contactor breaker LU2B32B |
| [Ue] rated operational voltage | 690 V AC |
| Network frequency | 40...60 Hz |
| Load type | Single-phase motor |
| Utilisation category | AC-41; AC-43; AC-44 |
| Motor power kW | 2.2 kW at 400...440 V AC 50/60 Hz for 1 phase motors |
| rated motor current adjustment range | 3…12 A |
| Thermal overload class | Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…55 °C conforming to IEC 60947-6-2; Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…55 °C conforming to UL 508 |
| Tripping threshold | 14.2 x Ir +/- 20 % |
| [Uc] control circuit voltage | 24 V AC |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.5 cm |
| Package 1 Width | 8.0 cm |
| Package 1 Length | 10.0 cm |
| Package 1 Weight | 131.0 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 23 |
| Package 2 Height | 15.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 3.439 kg |
The extended control unit LUCC12B from Schneider Electric belongs to the TeSys series and is designed as part of the TeSys Ultra system. It is used for motor control and motor protection, combining control, switching, and contactor functions in a single device. The unit is modular in design and intended for industrial applications, particularly for controlling single-phase motors. The control unit is rated for an operating voltage of 690 V AC and operates within a frequency range of 40 to 60 Hz. It is suitable for usage categories AC-41, AC-43, and AC-44, qualifying it for applications with high load fluctuations and frequent switching operations.
Motor control and protection
The LUCC12B provides basic protection as well as advanced functions, including overload and short-circuit protection, phase failure and phase imbalance protection, and earth fault protection. The overload tripping class is Class 10, enabling a rapid response to overloads. The tripping threshold is set at 14.2 times the set rated current (Ir) ± 20 %, ensuring precise protection. The adjustable range for motor current is 3 to 12 A, with the unit designed for motors with a power rating of 2.2 kW at 400–440 V AC and 50/60 Hz. Manual reset allows for targeted reactivation after a tripping event.
Technology explained clearly
The control unit operates with a control voltage of 24 V AC. The control circuit voltage limits are 20–26.5 V for operation and 14.5 V for release. Typical power consumption is 140 mA at 24 V AC during closing with the base unit LUB12, with heat dissipation of 2 W. The response time is 35 ms for opening and 70 ms for closing, regardless of the connected base unit (LUB12, LUB32, LUB38). The unit is designed for an operating temperature range of -25 to 70 °C and can be used up to an operating altitude of 2,000 m. Shock resistance is 10 Gn with open current poles and 15 Gn with closed current poles; vibration resistance is 2 Gn with open and 4 Gn with closed current poles in the frequency range of 5 to 300 Hz.
Compatibility and accessories
The LUCC12B is compatible with various base units from the TeSys Ultra series, including the power bases LUB12, LUB32, LUB38, LUB120, LUB320, and LUB380, as well as the reversing contactor breakers LU2B12B and LU2B32B. The unit is plug-in mounted on the front and thus integrates flexibly into existing systems. Available accessories include communication modules such as the LULC15 for Advantys STB, the LULC033 for Modbus, or the LUFP9 as a gateway for DeviceNet/Modbus. Additionally, auxiliary switch modules such as the LUA8E20 or LUFN20, and display modules such as the LUFV2 for motor load indication, can be integrated.
Mounting and installation
Mounting is done via plug-in connection on the front of the base unit. The degree of protection is IP20 on the front plate and wired terminals, and IP40 on the front plate outside the connection zone, providing protection against touch and limited protection against solid foreign objects. The coating corresponds to category TH according to IEC 60068, indicating high resistance to environmental influences such as humidity and temperature fluctuations. Flame resistance is 960 °C for parts mounting current-carrying components and 650 °C for other parts, according to IEC 60695-2-12.
Operational advantages
The modular design enables flexible adaptation to different requirements. Integrated communication capability and support for various protection functions increase the safety and availability of the system. Compliance with international standards such as EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, and CSA C22.2 No. 60947-4-1, as well as certifications including CE, UL, CSA, CCC, EAC, ASEFA, ATEX, and Marine, ensure reliability and suitability for use in various industries. The safe circuit isolation of 400 V SELV between control and auxiliary circuits, and between control or auxiliary circuits and main circuits, complies with IEC 60947-1 and enhances operational safety.