Further information for Schneider Electric LUCB12BL Control Unit 24VDC
Complementary
Control circuit voltage limits
20...27 V for DC circuit 24 V in operation; 14.5 V for DC circuit 24 V drop-out
Typical current consumption
130 mA at 24 V DC I maximum while closing with LUB12; 220 mA at 24 V DC I maximum while closing with LUB32; 220 mA at 24 V DC I maximum while closing with LUB38; 60 mA at 24 V DC I rms sealed with LUB12; 80 mA at 24 V DC I rms sealed with LUB32; 80 mA at 24 V DC I rms sealed with LUB38
Heat dissipation
2 W for control circuit with LUB12; 3 W for control circuit with LUB32; 3 W for control circuit with LUB38
Operating time
35 ms opening with LUB12 for control circuit; 35 ms opening with LUB32 for control circuit; 35 ms opening with LUB38 for control circuit; 70 ms closing with LUB12 for control circuit; 70 ms closing with LUB32 for control circuit; 70 ms closing with LUB38 for control circuit
Reset
Manual reset
Standards
EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier
Product certifications
CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
[Ui] rated insulation voltage
690 V conforming to IEC 60947-6-2; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-6-2
Safe separation of circuit
400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
Fixing mode
Plug-in (front face)
Width
45 mm
Height
66 mm
Depth
60 mm
Compatibility code
LUCB
Contractual warranty
Warranty (in months)
18
Environment
IP degree of protection
IP20 front panel and wired terminals conforming to IEC 60947-1; IP20 other faces conforming to IEC 60947-1; IP40 front panel outside connection zone conforming to IEC 60947-1
Protective treatment
TH conforming to IEC 60068
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…85 °C
Operating altitude
2000 m
Fire resistance
960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12
Shock resistance
10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance
2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6; 4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6
Resistance to electrostatic discharge
8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2
Resistance to radiated fields
10 V/m 3 conforming to IEC 61000-4-3
Resistance to fast transients
2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Immunity to radioelectric fields
10 V conforming to IEC 61000-4-6
Immunity to microbreaks
3 ms
Immunity to voltage dips
70 % / 500 ms conforming to IEC 61000-4-11
Logistical informations
Country of origin
FR
Main
Range
TeSys
Range of product
TeSys Ultra
Product name
TeSys Ultra
Device short name
LUCB
Product or component type
Advanced control unit
Device application
Motor control; Motor protection
Product specific application
Basic protection and advanced functions, communication
main function available
Manual reset; Protection against phase failure and phase imbalance; Protection against overload and short-circuit; Earth fault protection
Product compatibility
Power base LUB12; Power base LUB32; Power base LUB38; Power base LUB120; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B12BL; Reversing contactor breaker LU2B32BL; Reversing contactor breaker LU2B38BL
[Ue] rated operational voltage
690 V AC
Network frequency
40...60 Hz
Load type
3-phase motor - cooling: self-cooled
Utilisation category
AC-41; AC-43; AC-44
Motor power kW
5.5 kW at 400...440 V AC 50/60 Hz; 5.5 kW at 500 V AC 50/60 Hz; 9 kW at 690 V AC 50/60 Hz
rated motor current adjustment range
3…12 A
Thermal overload class
Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to IEC 60947-6-2; Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to UL 508
Tripping threshold
14.2 x Ir +/- 20 %
[Uc] control circuit voltage
24 V DC
Phase failure sensitivity
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
5.000 cm
Package 1 Width
8.200 cm
Package 1 Length
8.800 cm
Package 1 Weight
124.000 g
Unit Type of Package 2
S02
Number of Units in Package 2
23
Package 2 Height
15.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
3.082 kg
The control unit Extended LUCB12BL from Schneider Electric belongs to the TeSys series and is designed as an Extended control unit for motor control and motor protection functions. It serves as a modular add-on device for the TeSys U contactor series and enables the integration of basic protection functions as well as extended monitoring and communication. The device is designed for use in industrial plants where reliable and precise control of three-phase motors is required, particularly in applications with self-cooling motors.
Applications
LUCB12BL is suitable for controlling and protecting three-phase motors in various industrial environments. It is used in plants where high operational safety and precise load monitoring are required. The usage categories AC-41, AC-43, and AC-44 indicate applications with frequent starting operations, reversing operating modes, and high mechanical loads. The motor power ranges up to 5.5 kW at 400–440 V AC and 9 kW at 690 V AC, enabling use in medium to large drive systems. The rated operational voltage is 690 V AC, allowing the device to be used in high-voltage installations.
Functions and Equipment in Detail
The control unit offers an adjustable range for rated current from 3 to 12 A, allowing flexible adaptation to different motor powers. The trip class 10 complies with standards IEC 60947-6-2 and UL 508 and ensures precise overload protection response. The trip threshold is set at 14.2 times the set value (Ir) ± 20 %, ensuring reliable response to overloads. Additionally, the device protects against phase failure and phase imbalance, which is particularly important in plants with irregular power supply. The manual reset allows targeted reactivation after a tripping event.
Technology Explained Simply
The control unit operates with a control voltage of 24 V DC, with an operating voltage range between 20 and 27 V and a drop-out value at 14.5 V. Typical power consumption is 130 mA during closing when connected to the base unit LUB12 and 60 mA in the sealed state. Heat dissipation is 2 W for the control circuit system when connected to LUB12. Response time is 35 ms for opening and 70 ms for closing, enabling rapid reaction to operational changes. The safe circuit disconnection of 400 V SELV between control and main circuits complies with IEC 60947-1 requirements and ensures a high protection standard.
Compatibility and Accessories
LUCB12BL is compatible with various base units of the TeSys U series, including Power bases LUB12, LUB32, LUB38, LUB120, LUB320, and LUB380, as well as with reversing contactor breakers LU2B12BL, LU2B32BL, and LU2B38BL. Connection is via front-side plug-in, enabling easy installation and replaceability. Available accessories include various modules, such as communication modules like the AS-i module ASILUFC51, the Modbus module LULC033, or the CANopen module LULC08. Auxiliary switch modules such as LUA8E20 or LUA1C11 can be used to extend signal transmission. The application module LUFV2 enables motor load indication via a 4–20 mA output.
Mounting and Installation
Mounting is done via plug-in connection at the front of the base unit. The protection rating is IP20 on the front plate and wired terminals, and IP40 on the front plate outside the connection zone, providing protection against contact and limited protection against solid objects and splashing water. The operating ambient temperature ranges from -25 °C to +70 °C, and the storage temperature ranges from -40 °C to +85 °C. The operating altitude is limited to 2,000 m above sea level. Flame resistance is 960 °C for mountable parts and 650 °C for other components, according to IEC 60695-2-12. Shock resistance is 10 Gn with open current poles, ensuring safe operation in mechanically stressed environments.
Operational Advantages
LUCB12BL offers high flexibility due to its modular design and compatibility with various base units. Integrated protection functions such as overload, short-circuit, and earth fault protection increase operational safety. The manual reset allows targeted reactivation, and communication modules enable integration into higher-level control systems. Compliance with international standards such as EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, and CSA C22.2 No. 60947-4-1, as well as certifications like CE, UL, CSA, CCC, EAC, ASEFA, ATEX, and Marine, ensures suitability for various markets and applications.
Standards and Certifications
The device complies with standards EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1 (with phase separator), and CSA C22.2 No. 60947-4-1 (with phase separator). The rated insulation voltage is 690 V (IEC) or 600 V (UL/CSA), and the rated impulse voltage withstand is 6 kV. Certifications include CE, UL, CSA, CCC, EAC, ASEFA, ATEX, and Marine, ensuring suitability for various industries and regions.
Dimensions and Mounting
Dimensions are 45 mm (width), 66 mm (height), and 60 mm (depth). Mounting is done via plug-in connection at the front of the base unit. The coating corresponds to category TH according to IEC 60068, ensuring high resistance to environmental conditions.