Heat dissipation3 W for control circuit with LUCA, LUCB, LUCC, LUCD; 1.8 W for control circuit with LUCM
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating time35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit; 50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit; 60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit; 70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit; 65 ms closing with LUCM for control circuit
Mechanical durability15 Mcycles
maximum operating rate3600 cyc/h
Product certificationsCE; UL; CSA; CCC; EAC
StandardsEN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier
[Ui] rated insulation voltage690 V conforming to IEC 60947-6-2 (pollution degree 3); 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-6-2
Safe separation of circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Fixing modeClipped (DIN rail); Screw-fixed (plate)
Connections - terminalsPower circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigid; Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end; Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable end; Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable end; Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigid; Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end; Control circuit: without connection
Tightening torqueControl circuit: 0.8…1.2 N.m flat screwdriver 5 mm; Control circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mm; Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm; Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm; Power circuit: 1.9…2.5 N.m pozidriv No 2 screwdriver 6 mm
Width45 mm
Height154 mm
Depth126 mm
Net weight0.865 kg
Compatibility codeLUB
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 conforming to IEC 60947-1 (front panel and wired terminals); IP20 conforming to IEC 60947-1 (other faces); IP40 conforming to IEC 60947-1 (front panel outside connection zone)
Protective treatmentTH conforming to IEC 60068
Ambient air temperature for operation-25…60 °C with LUCM; -25…70 °C with LUCA, LUCB, LUCC, LUCD
Ambient air temperature for storage-40…85 °C
Fire resistance960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12
Operating altitude2000 m
Shock resistance10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27; 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27
Resistance to electrostatic discharge8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2
Non-dissipating shock wave1 kV serial mode 24...240 V AC conforming to IEC 60947-6-2; 1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2; 2 kV common mode 24...240 V AC conforming to IEC 60947-6-2; 2 kV common mode 48...220 V DC conforming to IEC 60947-6-2
Resistance to fast transients2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Resistance to radiated fields10 V/m 3 conforming to IEC 61000-4-3
Immunity to radioelectric fields10 V conforming to IEC 61000-4-6
Immunity to microbreaks3 ms for control circuit
Immunity to voltage dips70 % / 500 ms conforming to IEC 61000-4-11
Logistical informations
Country of originFR
Main
RangeTeSys
Product nameTeSys Ultra
Device short nameLUB
Product or component typeNon reversing power base
Device applicationMotor control; Motor protection
Poles description3P
[Ue] rated operational voltage690 V AC for power circuit
Network frequency40...60 Hz
[Ith] conventional free air thermal current38 A
[Ie] rated operational current35 A at
Utilisation categoryAC-43; AC-41
[Ics] rated service breaking capacity25 kA at 230 V; 25 kA at 440 V; 10 kA at 500 V; 4 kA at 690 V
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1; type mirror contact (1 NC) conforming to IEC 60947-1
[Uc] control circuit voltage24 V AC 50/60 Hz; 24 V DC; 48...72 V AC 50/60 Hz; 48...72 V DC; 110...240 V AC 50/60 Hz; 110...220 V DC
Suitability for isolationYes
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.300 cm
Package 1 Width14.500 cm
Package 1 Length16.700 cm
Package 1 Weight828.000 g
Unit Type of Package 2S02
Number of Units in Package 210
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.501 kg
TeSys U advanced power base, 3 Pole (3NO), 38A/690V, zu ergänzen mit einer Steuereinheit LUC, um eine TeSys U Startersteuerung zu bilden, für 3-Phasen-Motoranwendungen bis zu 18,5kW@400V. Basis bestehend aus Leistungskontakten, Steuerspule, Drehgriff, mit modularem Aufbau für zusätzliche Module zur Bildung eines 'all in one'-Startercontrollers mit einfachen oder erweiterten Schutz- und Steuerfunktionen. Er ist mit Hilfsmeldekontakten (1NO+1NC), einem Steuerklemmenblock und Blindabdeckungen für die leeren Hohlräume ausgestattet. Es bietet ein hohes Ausschaltvermögen Icu 25kA@400V, Start-Stopp-Steuerung garantiert für 3600 Zyklen/Stunde. Sehr kompakt (45mm Breite), DIN-Schienen-Montage und Schraubbefestigung, mit einem abschließbaren Drehgriff. Zertifiziert bei Verwendung in Verbindung mit einer LUC-Steuereinheit (IEC, UL, CSA, CCC, EAC), Green Premium-konform (RoHS/REACh).