General
ManufacturerSchneider Electric
Product family/seriesTeSys U
Product typeBase unit / power base
Nominal current12 A
Control unit configurationScrew terminals
Number of poles3-pole (3P)
Complementary
Heat dissipation2 W for control circuit with LUCA, LUCB, LUCC, LUCD; 1.7 W for control circuit with LUCM
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating time35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit; 50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit; 60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit; 70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit; 75 ms closing with LUCM for control circuit
Mechanical durability15 Mcycles
maximum operating rate3600 cyc/h
Product certificationsCE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
StandardsEN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier
[Ui] rated insulation voltage690 V conforming to IEC 60947-6-2 (pollution degree 3); 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-6-2
Safe separation of circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Fixing modeClipped (DIN rail); Screw-fixed (plate)
Tightening torqueControl circuit: 0.8…1.2 N.m flat screwdriver 5 mm; Control circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mm; Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm; Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm; Power circuit: 1.9…2.5 N.m pozidriv No 2 screwdriver 6 mm
Width45 mm
Height154 mm
Depth126 mm
Net weight0.9 kg
Compatibility codeLUB
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 conforming to IEC 60947-1 (front panel and wired terminals); IP20 conforming to IEC 60947-1 (other faces); IP40 conforming to IEC 60947-1 (front panel outside connection zone)
Protective treatmentTH conforming to IEC 60068
Ambient air temperature for operation-25…60 °C with LUCM; -25…70 °C with LUCA, LUCB, LUCC, LUCD
Ambient air temperature for storage-40…85 °C
Fire resistance960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12
Operating altitude2000 m
Shock resistance10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27; 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27
Resistance to electrostatic discharge8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2
Non-dissipating shock wave1 kV serial mode 24...240 V AC conforming to IEC 60947-6-2; 1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2; 2 kV common mode 24...240 V AC conforming to IEC 60947-6-2; 2 kV common mode 48...220 V DC conforming to IEC 60947-6-2
Resistance to fast transients2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Resistance to radiated fields10 V/m 3 conforming to IEC 61000-4-3
Immunity to radioelectric fields10 V conforming to IEC 61000-4-6
Immunity to microbreaks3 ms for control circuit
Immunity to voltage dips70 % / 500 ms conforming to IEC 61000-4-11
Logistical informations
Country of originFR
Main
RangeTeSys
Product nameTeSys Ultra
Device short nameLUB
Product or component typeNon reversing power base
Device applicationMotor control; Motor protection
Poles description3P
[Ue] rated operational voltage690 V AC for power circuit
Network frequency40...60 Hz
[Ith] conventional free air thermal current12 A
[Ie] rated operational current12 A at
Utilisation categoryAC-43; AC-44; AC-41
[Ics] rated service breaking capacity50 kA at 230 V; 50 kA at 440 V; 10 kA at 500 V; 4 kA at 690 V
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1; type mirror contact (1 NC) conforming to IEC 60947-1
[Uc] control circuit voltage24 V AC 50/60 Hz; 24 V DC; 48...72 V AC 50/60 Hz; 48...72 V DC; 110...240 V AC 50/60 Hz; 110...220 V DC
Suitability for isolationYes
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.200 cm
Package 1 Width13.500 cm
Package 1 Length17.000 cm
Package 1 Weight844.000 g
Unit Type of Package 2S02
Number of Units in Package 210
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.698 kg
Unit Type of Package 3P06
Number of Units in Package 3160
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight147.668 kg
The Schneider Electric LUB12 is a universal base unit of the TeSys U series, specifically designed as a power base for industrial motor starters. It combines the functions of a motor protection switch and a contactor in a compact module, enabling efficient and reliable motor control. With a rated current of 12 A and a rated power of 0.1 to 5.5 kW, it covers a wide range of applications, particularly for drives with low to medium power. The compact width of only 45 mm for powers up to 15 kW ensures space-saving installation, especially in control cabinets with limited space. A key advantage of the LUB12 is its modular design: the control voltage and exact current range are set only during final assembly via a plug-in control unit, offering high flexibility and adaptability to different requirements. The integrated protection and switching combination is standard-equipped with two auxiliary contacts (1 NC + 1 NO) and complies with IEC 947-6-2 requirements, including arc-free coordination. This makes the device suitable for use in demanding industrial environments where reliability and safety are paramount.