Schneider Electric LU2B38FU, EAN: 3606481493675

Schneider Electric LU2B38FU reversing combination 38A 110-240V AC/DC

Schneider Electric LU2B38FU reversing combination 38A 110-240V AC/DC

Lieske Part No. 1017134
Mfg Part No LU2B38FU
EAN-Code 3606481493675
Manufacturer Schneider Electric
Here only 232,59 EUR
276,78 EUR incl. VAT

Further information for Schneider Electric LU2B38FU reversing combination 38A 110-240V AC/DC

Complementary
Typical current consumption1000 mA at 110...220 V DC I maximum while closing; 1000 mA at 110...240 V AC I maximum while closing
Heat dissipation3 W for control circuit with LUCA, LUCB, LUCC, LUCD; 1.8 W for control circuit with LUCM
Inrush restraint duration25 ms AC 50/60 Hz; 15 ms DC
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating time150 ms with change of direction for power circuit; 35 ms opening for control circuit; 75 ms without change of direction for power circuit; 50 ms closing for control circuit
Mechanical durability15 Mcycles
maximum operating rate3600 cyc/h
Product certificationsCE; UL; CSA; CCC; EAC
StandardsEN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier
[Ui] rated insulation voltage690 V conforming to IEC 60947-6-2 (pollution degree 3); 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-6-2
Safe separation of circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Fixing modeClipped (DIN rail); Screw-fixed (plate)
Tightening torqueControl circuit: 0.8…1.2 N.m flat screwdriver 5 mm; Control circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mm; Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm; Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm; Power circuit: 1.9…2.5 N.m pozidriv No 2 screwdriver 6 mm
Width45 mm
Height224 mm
Depth126 mm
Net weight1.27 kg
Compatibility codeLU2B
Contractual warranty
Warranty (in months)18
Environment
IP degree of protectionIP20 conforming to IEC 60947-1 (front panel and wired terminals); IP20 conforming to IEC 60947-1 (other faces); IP40 conforming to IEC 60947-1 (front panel outside connection zone)
Protective treatmentTH conforming to IEC 60068
Ambient air temperature for operation-25…60 °C with LUCM; -25…70 °C with LUCA, LUCB, LUCC, LUCD
Ambient air temperature for storage-40…85 °C
Fire resistance960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12
Operating altitude2000 m
Shock resistance10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27; 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27
Resistance to electrostatic discharge8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2
Non-dissipating shock wave1 kV serial mode conforming to IEC 60947-6-2; 2 kV common mode conforming to IEC 60947-6-2
Resistance to fast transients2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Resistance to radiated fields10 V/m 3 conforming to IEC 61000-4-3
Immunity to radioelectric fields10 V conforming to IEC 61000-4-6
Immunity to microbreaks3 ms for control circuit
Immunity to voltage dips70 % / 500 ms conforming to IEC 61000-4-11
Logistical informations
Country of originFR
Main
RangeTeSys
Product nameTeSys Ultra
Device short nameLU2B
Product or component typeReversing power base
Device applicationMotor control; Motor protection
Product compatibilityControl unit LUC.X6FU; Control unit LUC.1XFU; Control unit LUC.05FU; Control unit LUC.12FU; Control unit LUC.18FU; Control unit LUC.32FU; Control unit LUC.38FU
Poles description3P
[Ue] rated operational voltage690 V AC for power circuit
Network frequency40...60 Hz
[Ith] conventional free air thermal current38 A
[Ie] rated operational current35 A at
Utilisation categoryAC-43; AC-41
[Ics] rated service breaking capacity25 kA at 230 V; 25 kA at 440 V; 10 kA at 500 V; 4 kA at 690 V
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1; type mirror contact (1 NC) conforming to IEC 60947-1
[Uc] control circuit voltage110...240 V AC 50/60 Hz; 110...220 V DC
Control circuit voltage limits55 V DC drop-out; 55 V AC drop-out; 88...242 V DC in operation; 88...264 V AC in operation
Suitability for isolationYes
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.500 cm
Package 1 Width15.000 cm
Package 1 Length25.200 cm
Package 1 Weight1.303 kg
Unit Type of Package 2S03
Number of Units in Package 22
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight3.077 kg
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1017134
qrcode für Schneider Electric LU2B38FU reversing combination 38A 110-240V AC/DC