Further information for Schneider Electric LU2B12FU contactor 12 A 110–220 V DC
Complementary
Typical current consumption
1000 mA at 110...220 V DC I maximum while closing; 1000 mA at 110...240 V AC I maximum while closing
Heat dissipation
2 W for control circuit with LUCA, LUCB, LUCC, LUCD; 1.7 W for control circuit with LUCM
Inrush restraint duration
25 ms AC 50/60 Hz; 15 ms DC
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating time
150 ms with change of direction for power circuit; 35 ms opening for control circuit; 75 ms without change of direction for power circuit; 50 ms closing for control circuit
Mechanical durability
15 Mcycles
maximum operating rate
3600 cyc/h
Product certifications
CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
Standards
EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier
[Ui] rated insulation voltage
690 V conforming to IEC 60947-6-2 (pollution degree 3); 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-6-2
Safe separation of circuit
400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Fixing mode
Clipped (DIN rail); Screw-fixed (plate)
Tightening torque
Control circuit: 0.8…1.2 N.m flat screwdriver 5 mm; Control circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mm; Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm; Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm; Power circuit: 1.9…2.5 N.m pozidriv No 2 screwdriver 6 mm
Width
45 mm
Height
224 mm
Depth
126 mm
Net weight
1.27 kg
Compatibility code
LU2B
Contractual warranty
Warranty (in months)
18
Environment
IP degree of protection
IP20 conforming to IEC 60947-1 (front panel and wired terminals); IP20 conforming to IEC 60947-1 (other faces); IP40 conforming to IEC 60947-1 (front panel outside connection zone)
Protective treatment
TH conforming to IEC 60068
Ambient air temperature for operation
-25…60 °C with LUCM; -25…70 °C with LUCA, LUCB, LUCC, LUCD
Ambient air temperature for storage
-40…85 °C
Fire resistance
960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12
Operating altitude
2000 m
Shock resistance
10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance
2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27; 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27
Resistance to electrostatic discharge
8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2
Non-dissipating shock wave
1 kV serial mode conforming to IEC 60947-6-2; 2 kV common mode conforming to IEC 60947-6-2
Resistance to fast transients
2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Resistance to radiated fields
10 V/m 3 conforming to IEC 61000-4-3
Immunity to radioelectric fields
10 V conforming to IEC 61000-4-6
Immunity to microbreaks
3 ms for control circuit
Immunity to voltage dips
70 % / 500 ms conforming to IEC 61000-4-11
Logistical informations
Country of origin
FR
Main
Range
TeSys
Product name
TeSys Ultra
Device short name
LU2B
Product or component type
Reversing power base
Device application
Motor control; Motor protection
Product compatibility
Control unit LUC.X6FU; Control unit LUC.1XFU; Control unit LUC.05FU; Control unit LUC.12FU
Poles description
3P
[Ue] rated operational voltage
690 V AC for power circuit
Network frequency
40...60 Hz
[Ith] conventional free air thermal current
12 A
[Ie] rated operational current
12 A at
Utilisation category
AC-43; AC-44; AC-41
[Ics] rated service breaking capacity
50 kA at 230 V; 50 kA at 440 V; 10 kA at 500 V; 4 kA at 690 V
Auxiliary contact composition
1 NO + 1 NC
Auxiliary contacts type
type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1; type mirror contact (1 NC) conforming to IEC 60947-1
[Uc] control circuit voltage
110...240 V AC 50/60 Hz; 110...220 V DC
Control circuit voltage limits
55 V DC drop-out; 55 V AC drop-out; 88...242 V DC in operation; 88...264 V AC in operation
Suitability for isolation
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
25.500 cm
Package 1 Width
5.500 cm
Package 1 Length
15.300 cm
Package 1 Weight
1.295 kg
Unit Type of Package 2
S03
Number of Units in Package 2
9
Package 2 Height
30.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
12.141 kg
Basic units Universal basic equipment, standard to 12/32 A and with 2 auxiliary contacts (1 NO + 1 NC), width up to 15 kW only 45 mm, complete coordination according to IEC 947-6-2, reversing contactor only 45 mm wide. Finish: Direction of rotation ( en) 2 Product Class: Rated power AC-3, 400 V, 0.1 ... 5.5 kW Type: LU2B12FU