Schneider Electric LRD32, EAN: 3389110346855

Schneider Electric LRD32 motor protection relay 23-32A

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LRD32 motor protection relay 23-32A

Lieske Part No. 214799
Mfg Part No LRD32
EAN-Code 3389110346855
Manufacturer Schneider Electric
Here only 115,90 EUR
137,92 EUR incl. VAT

Further information for Schneider Electric LRD32 motor protection relay 23-32A

Complementary
Network frequency0...400 Hz
Mounting supportPlate, with specific accessories; Rail, with specific accessories; Under contactor
Tripping threshold1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Auxiliary contact composition1 NO + 1 NC
[Ith] conventional free air thermal current5 A for signalling circuit
Permissible current1.5 A at 240 V AC-15 for signalling circuit; 0.1 A at 250 V DC-13 for signalling circuit
[Ue] rated operational voltage690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1
Associated fuse rating4 A gG for signalling circuit; 4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage6 kV
Phase failure sensitivityTripping current 130 % of Ir on two phase, the last one at 0
Control typeRed push-button: stop; Blue push-button: reset
Temperature compensation-20…60 °C
Connections - terminalsControl circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid; Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end; Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end; Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² solid
Tightening torqueControl circuit: 1.7 N.m - on screw clamp terminals; Power circuit: 2.5 N.m - on screw clamp terminals
Height66 mm
Width45 mm
Depth70 mm
Net weight0.124 kg
Contractual warranty
Warranty (in months)18
Environment
Climatic withstandconforming to IACS E10
IP degree of protectionIP20 conforming to IEC 60529
Ambient air temperature for operation-20…60 °C without derating conforming to IEC 60947-4-1
Ambient air temperature for storage-60…70 °C
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations: 6 Gn conforming to IEC 60068-2-6; Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
Dielectric strength1.89 kV at 50 Hz conforming to IEC 60947-1
StandardsEN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; GB/T 14048.4; GB/T 14048.5; EN 50495
Product certificationsIEC; UL; CSA; CCC; EAC; BV; RINA; DNV-GL; LROS (Lloyds register of shipping); ATEX INERIS; UKCA
Logistical informations
Country of originFR
Main
RangeTeSys; TeSys Deca
Product nameTeSys LRD; TeSys Deca
Product or component typeDifferential thermal overload relay
Device short nameLRD
Relay applicationMotor protection
Product compatibilityLC1D32; LC1D25; LC1D38
Network typeAC; DC
Thermal overload classClass 10A conforming to IEC 60947-4-1
Thermal protection adjustment range23…32 A
[Ui] rated insulation voltagePower circuit: 600 V conforming to CSA; Power circuit: 600 V conforming to UL; Power circuit: 690 V conforming to IEC 60947-4-1
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width7.800 cm
Package 1 Length8.800 cm
Package 1 Weight142.000 g
Unit Type of Package 2S02
Number of Units in Package 224
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight3.720 kg
Unit Type of Package 3P06
Number of Units in Package 3384
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight67.520 kg
The motor protection relay LRD32 from the TeSys Deca series by Schneider Electric is a thermal overload relay with differential protection, specifically designed for protecting electric motors in industrial applications. It serves as a protective component mounted directly beneath a contactor and covers motor ratings from 23 to 32 amperes. The devices are designed for use in AC and DC networks and operate within a frequency range of 0 to 400 Hz. The thermal trip class 10 A complies with IEC 60947-4-1 and ensures precise response to overloads, with the trip threshold set at 1.14 ± 0.06 times the set nominal current (Ir). Temperature compensation in the range of -20 to 60 °C ensures reliable operation regardless of environmental influences.

Applications include motor protection in production plants, conveyor systems, pump and fan drives, and other industrial drive systems where high operational reliability is required. The device is compatible with contactor types LC1D32, LC1D25, and LC1D38, enabling flexible integration into existing control systems. Phase loss sensitivity is defined by a trip condition of 130 % of the set current on two phases when the third phase is disconnected, providing reliable protection against unbalanced operating conditions.

Functions and features in detail include a spring-loaded connection for mounting beneath the contactor, as well as a front panel with two control buttons: a red button for triggering the test function and a blue button for Off" and "Manual reset functions. A yellow mechanical indicator visually signals the tripped state. Resetting can be done either manually or automatically, with the setting adjusted directly on the device front. The auxiliary contacts consist of 1 normally closed and 1 normally open contact (1S+1Oe), which can be used for control and signaling purposes.

Technology explained simply shows that the relay features screw terminals for both power and control circuits. In the power circuit, cables with a cross-section of 1.5 to 10 mm² (flexible or rigid) can be connected, with flexible cables without end ferrules allowing a cross-section of 1 to 6 mm². In the control circuit, cables with 1 to 2.5 mm² (flexible or rigid) are permissible. The torque values are 2.5 Nm for the power circuit and 1.7 Nm for the control circuit. The rated operational voltage is 690 V AC, the rated insulation voltage is 600 V (CSA/UL) or 690 V (IEC). The impulse voltage withstand is specified at 6 kV, ensuring high electrical strength. The dielectric strength is 1.89 kV at 50 Hz.

Compatibility and accessories include use with the mentioned contactor types LC1D32, LC1D25, and LC1D38. Accessories available include, for example, the wiring kit LAD7C2 for D25–D38, remote tripping units such as LAD703F or LA-D703M, and reset buttons such as XB5AL84101 (red, projecting) or XB5AA86102 (blue, flush). These components enable extended functionality, such as remote control or improved operability in complex systems.

Mounting and installation can be done directly beneath the contactor, on a plate (with special accessories), or on a rail (also with special accessories). The protection rating IP20 according to IEC 60529 protects against finger contact and solid foreign objects, but is not suitable for outdoor use or in damp environments. The ambient temperature during operation ranges from -20 to 60 °C without performance reduction. The flame retardancy corresponds to class V1 according to UL 94. Mechanical robustness is defined by vibration loads of 6 Gn (IEC 60068-2-6) and shock loads of 15 Gn for 11 ms (IEC 60068-2-7).

Operational advantages include reliable overload and phase loss protection, easy operation via front buttons, clear visual indication, and flexible mounting options. Compliance with international standards such as EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, and GB/T 14048.4 ensures suitability for various markets. Certifications include IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS (Lloyds Register of Shipping), and ATEX INERIS, confirming suitability for demanding industrial and marine applications. The rated operational voltage of 690 V AC and the impulse voltage withstand of 6 kV ensure high electrical safety. The climate resistance meets IACS E10, supporting use in marine environments.

The device is available in single packaging (PCE) with a weight of 0.124 kg. Dimensions are 45 mm (width), 66 mm (height), and 70 mm (depth).
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/214799
qrcode für Schneider Electric LRD32 motor protection relay 23-32A