| Complementary |
| Network frequency | 0...400 Hz |
| Mounting support | Plate, with specific accessories; Rail, with specific accessories; Under contactor |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Permissible current | 1.5 A at 240 V AC-15 for signalling circuit; 0.1 A at 250 V DC-13 for signalling circuit |
| [Ue] rated operational voltage | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit; 4 A BS for signalling circuit |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Control type | Red push-button: stop; Blue push-button: reset |
| Temperature compensation | -20…60 °C |
| Connections - terminals | Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid; Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end; Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end; Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² solid |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminals; Power circuit: 2.5 N.m - on screw clamp terminals |
| Height | 66 mm |
| Width | 45 mm |
| Depth | 70 mm |
| Net weight | 0.124 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Climatic withstand | conforming to IACS E10 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Ambient air temperature for storage | -60…70 °C |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations: 6 Gn conforming to IEC 60068-2-6; Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 |
| Dielectric strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
| Standards | EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; GB/T 14048.4; GB/T 14048.5; EN 50495 |
| Product certifications | IEC; UL; CSA; CCC; EAC; BV; RINA; DNV-GL; LROS (Lloyds register of shipping); ATEX INERIS; UKCA |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys; TeSys Deca |
| Product name | TeSys LRD; TeSys Deca |
| Product or component type | Differential thermal overload relay |
| Device short name | LRD |
| Relay application | Motor protection |
| Product compatibility | LC1D25; LC1D32; LC1D38 |
| Network type | DC; AC |
| Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
| Thermal protection adjustment range | 16…24 A |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to CSA; Power circuit: 600 V conforming to UL; Power circuit: 690 V conforming to IEC 60947-4-1 |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 7.600 cm |
| Package 1 Length | 8.800 cm |
| Package 1 Weight | 142.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 3.712 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 384 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 68.500 kg |
The
motor protection relay LRD22 from the
TeSys Deca series by
Schneider Electric provides electrical protection for motors against overload. It is designed as a
thermal overload relay with differential protection and offers an adjustable range from 16 to 24 amperes. The protection function operates via a thermal trip class 10 A, specified according to IEC 60947-4-1. This means the relay trips within 10 seconds when the current reaches 1.14 times the set rated current, with a tolerance of ±0.06 Ir. The trip sensitivity for phase loss is set at 130 % of the set current on two phases, with the last phase at 0 %, enabling reliable detection of phase faults.
Applications
This relay is designed for use in industrial installations where motor protection is required. It is compatible with contactors LC1D25, LC1D32, and LC1D38, and is mounted directly beneath the contactor. The devices are rated for operating voltages up to 690 V AC (0–400 Hz), with a rated insulation voltage of 690 V (IEC 60947-4-1). The impulse voltage withstand is 6 kV, ensuring high electrical safety. The operating temperature ranges from -20 °C to 60 °C without performance reduction, and the storage temperature ranges from -60 °C to 70 °C.
Functions and Equipment in Detail
The device features
manual or automatic reset, selectable via the front panel. Resetting is performed using a
blue button, which also serves the Off" and "Manual Reset functions. A
red button is used to trigger the test function. When the relay trips, a
yellow mechanical indicator becomes visible, providing a visual signal of the operating status. The auxiliary contacts are configured as
1 S + 1 Ö, enabling integration into control and monitoring systems. The control buttons are color-coded: red for stop, blue for reset.
Technology Explained Simply
The relay operates thermally, with heat generation caused by motor current controlling the tripping function.
Temperature compensation ensures that the tripping function remains constant regardless of ambient temperature between -20 °C and 60 °C. The
screw terminals allow secure connections for the power circuit (1.5–10 mm² flexible or rigid, with or without wire ends) and the control circuit (1–2.5 mm² flexible or rigid, with or without wire ends). The tightening torques are 2.5 Nm for the power circuit and 1.7 Nm for the control circuit. Mechanical robustness is designed for vibrations of 6 Gn (IEC 60068-2-6) and shocks of 15 Gn (11 ms, IEC 60068-2-7).
Compatibility and Accessories
The LRD22 is specifically intended for use with contactors LC1D25, LC1D32, and LC1D38. Compatible accessories include contactors such as LC1D25B7 and LC1D25P7, remote tripping devices such as LA-D703M and LAD703F, and wiring kits such as LAD7C2. Mounting is done directly beneath the contactor, with optional mounting on a plate or rail using special accessories. The associated fuse rating is 4 A gG or 4 A BS for the signal circuit.
Mounting and Installation
Mounting is done directly beneath the contactor, with device dimensions of 45 mm (width), 66 mm (height), and 70 mm (depth). The screw terminals allow for easy and secure connections. Mechanical robustness and climatic resistance (IACS E10) ensure reliable performance in industrial environments. The protection rating IP20 protects against finger contact and solid foreign objects, but not against water or dust.
Operational Advantages
The relay provides reliable motor protection with a thermal tripping function that responds to actual heat generation in the motor. The differential protection function detects phase loss and protects against motor damage. Manual and automatic reset options allow flexible adaptation to the requirements of the installation. The visual indicator and color-coded buttons simplify operation and maintenance. Compatibility with common contactor types and compliance with international standards (IEC 60947-4-1, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX INERIS, UKCA) ensure safe and standard-compliant integration into industrial installations.