Schneider Electric LR9D5367, EAN: 3389110113099

Schneider Electric LR9D5367 motor protection relay 60-100 A

Industrial Material > Control devices / Pilot devices > Motor protection switch

Schneider Electric LR9D5367 motor protection relay 60-100 A

Lieske Part No. 1773985
Mfg Part No LR9D5367
EAN-Code 3389110113099
Manufacturer Schneider Electric
Here only 460,75 EUR
548,29 EUR incl. VAT

Further information for Schneider Electric LR9D5367 motor protection relay 60-100 A

Complementary
Network frequency50...60 Hz
[Us] rated supply voltage24 V DC
Supply voltage limits17…32 V
Mounting supportUnder contactor; Rail
Tripping threshold1.05 +/- 0.06 In alarm conforming to IEC 60947-4-1; 1.12 +/- 0.06 In de-energisation conforming to IEC 60947-4-1
Auxiliary contact composition1 NO + 1 NC
[Ith] conventional free air thermal current5 A for signalling circuit
[Ue] rated operational voltage690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1
Associated fuse rating4 A gG for signalling circuit; 4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
Phase failure sensitivityTripping in 4 s +/- 20 % conforming to IEC 60947-4-1
Control typeRed push-button: stop; Blue push-button: reset
Temperature compensation-20…60 °C
Switching capacity in mA0...150 mA
Connections - terminalsPower circuit: bars; Control circuit: screw clamp terminals 1 cable(s) 0.5…1.5 mm² flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 0.5…1.5 mm² flexible without cable end; Alarm circuit: screw clamp terminals 1 cable(s) 0.5…1.5 mm² flexible without cable end
Tightening torqueAlarm circuit: 0.45 N.m - on screw clamp terminals; Power circuit: 18 N.m - on bars M8; Control circuit: 1.2 N.m - on screw clamp terminals
Height118 mm
Width115 mm
Depth125 mm
Net weight0.885 kg
Contractual warranty
Warranty (in months)18
Environment
Climatic withstandconforming to IACS E10
IP degree of protectionIP20 conforming to IEC 60529
Ambient air temperature for operation-20…60 °C without derating conforming to IEC 60947-4-1
Ambient air temperature for storage-60…70 °C
Mechanical robustnessVibrations: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6; Shocks: 13 Gn for 11 ms conforming to IEC 60068-2-7
Dielectric strength1.89 kV at 50 Hz conforming to IEC 60947-1
StandardsEN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; GB/T 14048.4; GB/T 14048.5
Product certificationsUL; CSA; CCC; UKCA
Logistical informations
Country of originFR
Main
RangeTeSys
Product nameTeSys LRD; TeSys Deca
Product or component typeElectronic thermal overload relay
Device short nameLR9D
Relay applicationMotor protection
Product compatibilityLC1D115; LC1D150; NSX circuit breaker
Network typeAC
Thermal overload classClass 10 conforming to IEC 60947-4-1
Signalling functionAlarm
Thermal protection adjustment range60…100 A
[Ui] rated insulation voltagePower circuit: 1000 V conforming to IEC 60947-4-1; Power circuit: 600 V conforming to CSA; Power circuit: 600 V conforming to UL
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.000 cm
Package 1 Width16.000 cm
Package 1 Length13.000 cm
Package 1 Weight934.000 g
Unit Type of Package 2S04
Number of Units in Package 212
Package 2 Height30.000 cm
Package 2 Width40.000 cm
Package 2 Length60.000 cm
Package 2 Weight11.978 kg
Unit Type of Package 3P06
Number of Units in Package 348
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight56.000 kg
The motor protection relay LR9D5367 from the TeSys series by Schneider Electric is an electronic thermal overload relay designed for industrial applications. It protects electric motors against thermal overload and is specifically designed for applications in the 60 to 100 A range. The device is part of the TeSys LRD and TeSys Deca families and is used in combination with contactors such as LC1D115, LC1D150, or NSX circuit breakers to create a compact and reliable motor starter. The protection function operates according to thermal trip class 10, as defined by IEC 60947-4-1, ensuring precise adaptation to the thermal characteristics of the motor.

Applications
This relay is designed for use in industrial drive systems, particularly in installations with motors in the power range of 0.06 to 75 kW. It protects motors against overload caused by continuous or short-term current overloads, phase loss, and other disturbances. The relay is used in electrical control panels where reliable motor monitoring is required, for example in manufacturing, process engineering, or pump and fan applications. The operating temperature range of -20 to 60 °C allows use in a wide variety of environments without requiring derating.

Functions and Features in Detail
The device features manual and automatic reset, with reset performed via a red pushbutton (stop) and a blue pushbutton (reset). Signaling is provided by an integrated alarm, which activates when the relay trips. The auxiliary contacts are configured as 1 NO + 1 NC, enabling flexible integration into control and monitoring systems. The trip threshold is 1.05 ± 0.06 In for alarm and 1.12 ± 0.06 In for disconnection, in accordance with IEC 60947-4-1. In the event of phase loss, the relay trips within 4 seconds ± 20%. The temperature compensation function ensures stable protection performance in ambient temperatures between -20 and 60 °C.

Technical Explanation
The relay operates using an electronic thermal overload protection function, which simulates heat development in the motor and disconnects the motor when permissible values are exceeded. Power supply is via 24 V DC, with a tolerance range of 17 to 32 V. The rated operating voltage for the power circuit is 690 V AC at frequencies from 0 to 400 Hz. The rated insulation voltage is 1000 V (IEC 60947-4-1), 600 V (CSA), and 600 V (UL). The rated impulse withstand voltage is 6 kV, ensuring high electrical strength even under transient voltage surges. The dielectric strength is 1.89 kV at 50 Hz. The conventional thermal current in the signaling circuit is 5 A.

Compatibility and Accessories
The relay is compatible with contactors LC1D115, LC1D150, and NSX circuit breakers. It can be enhanced with accessories such as the reset button XB5AL84101 (red, projecting) or XB5AA86102 (blue, flush) to optimize operation. Remote operation is possible using accessory LA7D305. Alternatively, the device can be combined with other TeSys products such as GV4LE115N or GV4L115N. The successor model is specified as LR9G115 (28–115 A).

Mounting and Installation
Mounting is either under the contactor or on a rail. Connections consist of rails for the power circuit and screw terminals for the control and alarm circuits. Cable cross-sections for control and alarm circuits range from 0.5 to 1.5 mm² flexible, without cable ends. Tightening torques are 18 Nm for rails, 1.2 Nm for control terminals, and 0.45 Nm for alarm circuits. The protection rating IP20 according to IEC 60529 protects against finger contact and solid foreign objects, but is not waterproof. Mechanical robustness is certified according to IEC 60068-2-6 (vibrations: 2 Gn, 5–300 Hz) and IEC 60068-2-7 (shocks: 13 Gn, 11 ms).

Operational Advantages
The relay offers high reliability through electronic thermal simulation, enabling precise adaptation to motor load. The integrated signaling and manual/automatic reset simplify maintenance and operation. Combination with TeSys D contactors results in a compact starter, saving space in the enclosure. Certifications according to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, and CCC ensure compliance with international safety and quality standards. The operating temperature range of -20 to 60 °C and mechanical robustness make the device suitable for demanding industrial applications.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1773985
qrcode für Schneider Electric LR9D5367 motor protection relay 60-100 A