Schneider Electric LR2K0316, EAN: 3389110230581

Schneider Electric LR2K0316 motor protection relay 8,0-11,5A

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LR2K0316 motor protection relay 8,0-11,5A

Lieske Part No. 364241
Mfg Part No LR2K0316
EAN-Code 3389110230581
Manufacturer Schneider Electric
Here only 67,92 EUR
80,82 EUR incl. VAT

Further information for Schneider Electric LR2K0316 motor protection relay 8,0-11,5A

Complementary
Mounting supportUnder contactor; Plate, with specific accessories; Rail, with specific accessories
Auxiliary contact composition1 NO + 1 NC
[Ith] conventional free air thermal current6 A for signalling circuit
Associated fuse rating6 A gG for signalling circuit conforming to VDE 0660; 6 A gG for signalling circuit conforming to IEC 60947
[Uimp] rated impulse withstand voltage6 kV
Power dissipation per pole2 W
Phase failure sensitivityYes conforming to IEC 60947-4-1
Local signallingTrip indicator (yellow)
Control typeRed push-button: trip test function; Blue push-button: stop and manual reset; selector switch: manual or automatic reset
Connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Tightening torque1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2; 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; 1.3 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Height58 mm
Width45 mm
Depth65 mm
Net weight0.145 kg
Contractual warranty
Warranty (in months)18
Environment
StandardsIEC 60947; VDE 0660; BS 4941; NF C 63-650
Product certificationsUL; CSA; UKCA
Protective treatmentTC conforming to IEC 60068; TC conforming to DIN 50016
IP degree of protectionIP2X conforming to IEC 60529
Ambient air temperature for operation-20…55 °C without derating conforming to IEC 60947; -30…60 °C with derating conforming to IEC 60947
Ambient air temperature for storage-40…70 °C
Operating altitude2000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102
Mechanical robustnessShocks NO contact: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks NC contact: 10 Gn for 11 ms conforming to IEC 60068-2-27; Vibrations NO contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6; Vibrations NC contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Logistical informations
Country of originCZ
Main
RangeTeSys
Product nameTeSys LRK
Product or component typeDifferential thermal overload relay
Device short nameLR2K
Relay applicationMotor protection
Product compatibilityLC7K; LP1K; LC1K; LP4K
Network typeDC; AC
Thermal overload classClass 10A conforming to IEC 60947-4-1
Thermal protection adjustment range8…11.5 A
[Ui] rated insulation voltagePower circuit: 690 V conforming to BS 4941; Power circuit: 690 V conforming to IEC 60947; Power circuit: 750 V conforming to VDE 0110 group C; Power circuit: 600 V conforming to CSA C22.2 No 14
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.200 cm
Package 1 Width4.800 cm
Package 1 Length8.500 cm
Package 1 Weight157.000 g
Unit Type of Package 2S02
Number of Units in Package 241
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.855 kg
The motor protection relay LR2K0316 from the TeSys series by Schneider Electric is a thermal overload relay with differential protection, specifically designed for use in industrial drive systems. It protects electric motors against overload and phase failure, with the thermal protection setting range between 8 and 11.5 A. The trip class is Class 10 A, enabling fast response to overloads in accordance with IEC 60947-4-1. The device is designed for use in AC and DC networks and is suitable for motor protection applications with contactor types LC7K, LP1K, LC1K, and LP4K.

Applications include industrial automation, particularly in systems with electric drives, where reliable motor monitoring is required. The relay is designed for operation in environments with an operating temperature of -20 to 55 °C without derating, while derating is required at temperatures from -30 to 60 °C. The operating altitude is up to 2,000 m without derating. The protection rating IP2x in accordance with IEC 60529 protects against contact with fingers and larger solid objects, but not against water or dust.

Functions and equipment in detail include a temperature-compensated tripping function with differential protection, which detects phase failures. Local signaling is provided by a yellow mechanical trip indicator, visible when tripped. Resetting can be set via a selector switch to manual or automatic. A red pushbutton is used to activate the test function, while a blue pushbutton performs the Off" and "manual reset functions. The auxiliary contacts consist of 1 normally closed and 1 normally open contact, facilitating integration into control systems.

Technology explained simply shows that the relay features screw terminals suitable for various cable cross-sections: rigid 1.5 to 4 mm², flexible 0.75 to 4 mm² without cable end ferrule, and flexible 0.34 to 2.5 mm² with cable end ferrule. The tightening torque is 1.3 Nm, with installation using a Phillips screwdriver No. 2, a flat screwdriver Ø 6, or a positioning screwdriver No. 2. The rated insulation voltage is 690 V in accordance with IEC 60947 and BS 4941, as well as 750 V in accordance with VDE 0110 Group C and 600 V in accordance with CSA C22.2 No. 14. The rated impulse voltage withstand is 6 kV, and the power loss per pole is 2 W. The associated fuse for the signaling circuit is a 6 A gG fuse in accordance with VDE 0660 and IEC 60947.

Compatibility and accessories include use with contactor types LC7K, LP1K, LC1K, and LP4K. Suitable accessories include various contactors from the TeSys series, such as LC1K0910R7, LC1K0910F72, LC1K0910D7, LC1K0901B72, LP2K0901BD, LC2K0910B7TQ, LC1K09107E7, LC2K0910D7, carrier LA7-K0064 for LR2-K, LC1K0910E7, LP1K0910SD, LC2K0901E7, LC1K0901V7, LP1K0901ED, LP1K0910BD, LC1K0910B7TQ, LC1K0910U7, LP1K0910ED3, LC2K0910P7, and LC2K0901F72. These components enable flexible integration into existing systems.

Mounting and installation is done directly under the contactor, with mounting on panel or rail also possible using special accessories. Dimensions are 58 mm height, 45 mm width, and 65 mm depth, with a product weight of 0.145 kg. Mechanical robustness is certified in accordance with IEC 60068-2-27 and IEC 60068-2-6 for shocks (10 Gn, 11 ms) and vibrations (2 Gn, 5–300 Hz). Flame retardancy meets UL 94 V1, NF F 16-101 Requirement 2, and NF F 16-102 Requirement 2. Fire resistance is 850 °C in accordance with IEC 60695-2-1.

Operational advantages include reliable motor monitoring via differential protection, which detects phase failures, and simple operation via front pushbuttons and selector switch. The temperature-compensated tripping ensures precise response regardless of ambient temperature. Integration into existing contactor systems is easy and quick due to compatibility with various TeSys contactors. Certifications in accordance with IEC 60947, VDE 0660, BS 4941, NF C 63-650, as well as product certifications UL, CSA, and UKCA, guarantee compliance with international standards.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/364241
qrcode für Schneider Electric LR2K0316 motor protection relay 8,0-11,5A