| Complementary |
| Mounting support | Under contactor; Plate, with specific accessories; Rail, with specific accessories |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Ith] conventional free air thermal current | 6 A for signalling circuit |
| Associated fuse rating | 6 A gG for signalling circuit conforming to VDE 0660; 6 A gG for signalling circuit conforming to IEC 60947 |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Power dissipation per pole | 2 W |
| Phase failure sensitivity | Yes conforming to IEC 60947-4-1 |
| Local signalling | Trip indicator (yellow) |
| Control type | Red push-button: trip test function; Blue push-button: stop and manual reset; selector switch: manual or automatic reset |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
| Tightening torque | 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2; 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; 1.3 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 65 mm |
| Net weight | 0.145 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | IEC 60947; VDE 0660; BS 4941; NF C 63-650 |
| Product certifications | UL; CSA; UKCA |
| Protective treatment | TC conforming to IEC 60068; TC conforming to DIN 50016 |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Ambient air temperature for operation | -20…55 °C without derating conforming to IEC 60947; -30…60 °C with derating conforming to IEC 60947 |
| Ambient air temperature for storage | -40…70 °C |
| Operating altitude | 2000 m without derating |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
| Mechanical robustness | Shocks NO contact: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks NC contact: 10 Gn for 11 ms conforming to IEC 60068-2-27; Vibrations NO contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6; Vibrations NC contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Logistical informations |
| Country of origin | CZ |
| Main |
| Range | TeSys |
| Product name | TeSys LRK |
| Product or component type | Differential thermal overload relay |
| Device short name | LR2K |
| Relay application | Motor protection |
| Product compatibility | LC7K; LP1K; LP4K; LC1K |
| Network type | DC; AC |
| Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
| Thermal protection adjustment range | 2.6…3.7 A |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to BS 4941; Power circuit: 690 V conforming to IEC 60947; Power circuit: 750 V conforming to VDE 0110 group C; Power circuit: 600 V conforming to CSA C22.2 No 14 |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 7.000 cm |
| Package 1 Length | 8.500 cm |
| Package 1 Weight | 158.400 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 41 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.731 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 656 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 60.000 cm |
| Package 3 Weight | 115.702 kg |
The Schneider Electric TeSys LRK motor protection relay, type LR2K0310, is a thermal overload relay with differential protection, specifically designed for use in industrial drive applications. It provides protection for electric motors against overload and phase failure. The device is part of the TeSys product range and is used in combination with contactors of types LC7K, LP1K, LP4K, and LC1K. The thermal trip class is 10 A according to IEC 60947-4-1, ensuring a rapid response to overloads. The adjustment range for thermal protection is between 2.6 and 3.7 A, making it suitable for motors with a rated current within this range. The rated insulation voltage is 690 V (IEC 60947) and 750 V (VDE 0110 Group C), enabling safe use in industrial networks.
Applications
This relay is intended for use in industrial plants, particularly in drive technology, where reliable motor protection is required. It is mounted directly beneath a contactor, creating a compact and integrated solution. Installation is on a plate or rail, requiring special accessories. The operating ambient temperature ranges from -20 °C to 55 °C without derating, with derating required between -30 °C and 60 °C. Storage temperature is -40 °C to 70 °C, and the operating altitude is up to 2,000 m without derating.
Functions and Features in Detail
The relay includes local signalling in the form of a yellow trip indicator, visible when tripped. Control functions include a red push-button for test function activation and a blue push-button for the Off function and manual reset. A selector switch allows selection between manual and automatic reset. The auxiliary contacts consist of one normally open (1 S) and one normally closed (1 Ö) contact, facilitating integration into control logic. Connections are made via screw terminals, designed for rigid cables 1.5 to 4 mm² and flexible cables 0.75 to 4 mm² (without cable end) or 0.34 to 2.5 mm² (with cable end). The tightening torque is 1.3 Nm, and installation can be performed using a Phillips screwdriver No. 2, a flat screwdriver Ø 6, or a screwdriver position No. 2.
Technology Explained Simply
The thermal overload relay responds to heat generation in the motor caused by excessive current flow. Temperature compensation ensures the trip function operates independently of ambient temperature. Differential protection detects phase failure, which is particularly important for three-phase motors. The rated impulse voltage withstand is 6 kV, ensuring high electrical strength. The power loss per pole is 2 W, limiting the thermal load on the device. The conventional thermal current (Ith) is 6 A for the signal circuit, with the corresponding fuse being 6 A gG (VDE 0660, IEC 60947).
Compatibility and Accessories
The relay is compatible with contactors of types LC7K, LP1K, LP4K, and LC1K. Suitable accessories include various contactor variants, such as reversing contactor combinations like LC2K0610P7, LC2K0610B7, LC2K0601U7, LP2K0601BD, LP5K0610BW3, LC2K0601P72, as well as power contactors like LC1K0610N7, LP1K0601SD, LC1K0610P7, LC1K0601E7, LC1K0610V7, LC1K0601B7, LC1K0610Q7, LC1K0610B7, LC1K0601P7TQ, LP4K0610BW3, LP4K0601BW3. These enable flexible integration into existing installations.
Mounting and Installation
Mounting is directly beneath the contactor, with fastening possible on a plate or rail using special accessories. Dimensions are 58 mm (height), 45 mm (width), and 65 mm (depth). The product weight is 0.145 kg. Mechanical robustness is specified according to IEC 60068-2-27 and IEC 60068-2-6, allowing shocks of 10 Gn for 11 ms and vibrations of 2 Gn in the frequency range 5–300 Hz. The coating corresponds to TC (IEC 60068, DIN 50016), and fire resistance is 850 °C (IEC 60695-2-1). Flame retardancy corresponds to V1 (UL 94) and requirement 2 (NF F 16-101, NF F 16-102).
Operational Advantages
The relay provides reliable motor protection with integrated phase failure detection. Local signalling and the test function simplify maintenance and diagnostics. The option for manual or automatic reset increases operational flexibility. Screw terminals enable secure and easy wiring. Certifications including UL, CSA, and UKCA, along with compliance with standards IEC 60947, VDE 0660, BS 4941, and NF C 63-650, guarantee the quality and safety of the device.