| Complementary |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 9 A (at |
| Control circuit type | DC wide range |
| [Uc] control circuit voltage | 24 V DC |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-3; 4 kW at 380...415 V AC 50/60 Hz AC-3; 4 kW at 440/690 V AC 50/60 Hz AC-3; 2.2 kW at 220...230 V AC 50/60 Hz AC-3e; 4 kW at 380...415 V AC 50/60 Hz AC-3e; 4 kW at 440/690 V AC 50/60 Hz AC-3e; 2.2 kW at 220...230 V AC 50/60 Hz AC-4; 4 kW at 380...415 V AC 50/60 Hz AC-4; 4 kW at 440/690 V AC 50/60 Hz AC-4 |
| Auxiliary contact composition | 1 NC |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Inrush power in W | 1.8 W (at 20 °C) |
| Hold-in power consumption in W | 1.8 W at 20 °C |
| Heat dissipation | 1.8 W |
| Control circuit voltage limits | Operational: 0.7...1.3 Uc (at = 0.10 Uc (at |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end; Power circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end |
| Maximum operating rate | 3600 cyc/h |
| Coil technology | With integral suppression device |
| Auxiliary contacts type | type instantaneous 1 NC |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Mounting support | Rail; Plate |
| Tightening torque | 0.8…1.3 N.m - on screw clamp terminals Philips No 2; 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm; 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2 |
| Operating time | 10...20 ms coil de-energisation and NO opening; 30...40 ms coil energisation and NO closing |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 30 Mcycles |
| Electrical durability | 1.3 Mcycles 9 A AC-3 at Ue |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Net weight | 0.235 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; GB/T 14048.4 |
| Product certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
| IP degree of protection | IP2X |
| Ambient air temperature for operation | -25…50 °C |
| Ambient air temperature for storage | -50…80 °C |
| Operating altitude | 2000 m without derating |
| Flame retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys |
| Product or component type | Contactor |
| Device short name | LP4K |
| Contactor application | Motor control; Resistive load |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.600 cm |
| Package 1 Width | 4.800 cm |
| Package 1 Length | 6.200 cm |
| Package 1 Weight | 221.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 40 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 9.222 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 320 |
| Package 3 Height | 45.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 82.540 kg |
The LP4K0901BW3 contactor from the TeSys series by Schneider Electric is a 3-pole contactor for controlling motors and resistive loads in industrial, infrastructure, and building technical applications. It features a coil with a control circuit voltage of 24 V DC and is designed for an operational rating of 9 A, with motor power up to 4 kW at 400 V AC and category AC-3. The device is designed for use in various application categories, including AC-1, AC-3, AC-3e, and AC-4, covering a wide range of load types and operating conditions. The integrated bidirectional amplitude-limiting diode ensures effective suppression of voltage spikes in the control circuit, enhancing the reliability and service life of the contactor.
Applications
This contactor is suitable for controlling electric motors in drive systems as well as resistive loads such as heaters or lighting systems. It is used in industrial automation, building and infrastructure technology, and machine control, where reliable and simple switching functions are required. The combination of mechanical robustness and electronic controllability makes it particularly suitable for applications with PLC control.
Functions and Equipment in Detail
The device features 3 close contacts in the main current circuit and an additional auxiliary contact configured as an open contact. This configuration enables direct motor control and provides feedback of the switching status to control devices. The auxiliary contacts are instantaneous and can be used for signals, such as status indication or feedback to a PLC. The coil is equipped with an integrated suppression unit that minimizes spark generation and voltage spikes.
Technology Explained Simply
The control circuit voltage of 24 V DC is a standard value in industrial electronics and allows for easy integration into existing control systems. The rated impulse voltage withstand is 8 kV, ensuring high electrical strength and safety during transient voltage spikes. The overvoltage category III indicates that the device is designed for installations with moderate overvoltage stress. The rated insulation voltage is 690 V for the current circuit and signal circuit according to IEC 60947-4-1, ensuring safe insulation between electrical circuits. The coil consumes 1.8 W for both pull-in and holding power at 20 °C, resulting in low heat dissipation and thus high efficiency.
Compatibility and Accessories
The contactor can be combined with various accessories to extend its functionality. These include auxiliary switch blocks such as the LA1KN20 (2 close contacts) or LA1KN02 (2 open contacts), enabling additional switching functions. For motor monitoring, motor protection relays such as the LR2K0314 (5.5–8.0 A) or motor protection switches such as the GV2ME14 (3p, 6–10 A) can be used. Energy meters such as the A9MEM1573 can be integrated into the installation for energy monitoring. Mounting is done on a rail or plate, enabling flexible installation in enclosures.
Mounting and Installation
Connections are made via screw terminals designed for various cable cross-sections: rigid 1.5 to 4 mm², flexible 0.75 to 4 mm² without cable end, and flexible 0.34 to 2.5 mm² with cable end. Mounting is on a rail or plate, with the tightening torque for the screw terminals ranging between 0.8 and 1.3 Nm. The maximum operating rate is 3600 switching operations per hour, enabling high dynamic performance during operation.
Advantages in Operation
The contactor is characterized by high operational reliability, long service life, and easy integration into existing control systems. The integrated suppression unit reduces electromagnetic interference and increases reliability. The low heat dissipation of 1.8 W ensures efficient cooling, even during continuous operation. Certifications according to CSA and UL confirm compliance with international safety standards. The compact design with dimensions 45 mm (width) × 58 mm (height) × 57 mm (depth) allows space-saving installation in enclosures.