| Complementary |
| Utilisation category | AC-3; AC-3e; AC-4 |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 6 A (at |
| Control circuit type | DC wide range |
| [Uc] control circuit voltage | 24 V DC |
| Motor power kW | 1.5 kW at 220...230 V AC 50/60 Hz AC-3; 2.2 kW at 380...415 V AC 50/60 Hz AC-3; 3 kW at 440/690 V AC 50/60 Hz AC-3; 1.5 kW at 220...230 V AC 50/60 Hz AC-3e; 2.2 kW at 380...415 V AC 50/60 Hz AC-3e; 3 kW at 440/690 V AC 50/60 Hz AC-3e; 1.5 kW at 220...230 V AC 50/60 Hz AC-4; 2.2 kW at 380...415 V AC 50/60 Hz AC-4; 3 kW at 440/690 V AC 50/60 Hz AC-4 |
| Auxiliary contact composition | 1 NO |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for control circuit conforming to IEC 60947; 10 A gG for control circuit conforming to VDE 0660; 25 A gG at |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Control circuit: 690 V conforming to BS 5424; Control circuit: 690 V conforming to IEC 60947; Power circuit: 690 V conforming to BS 5424; Power circuit: 690 V conforming to IEC 60947; Power circuit: 690 V conforming to NF C 20-040; Control circuit: 750 V conforming to VDE 0110 group C; Power circuit: 750 V conforming to VDE 0110 group C; Control circuit: 600 V conforming to CSA C22.2 No 14; Power circuit: 600 V UL 508 certified conforming to CSA C22.2 No 14 |
| Insulation resistance | > 10 MOhm for control circuit |
| Inrush power in W | 1.8 W (at 20 °C) |
| Hold-in power consumption in W | 1.8 W at 20 °C |
| Heat dissipation | 1.8 W |
| Control circuit voltage limits | Operational: 0.7...1.3 Uc (at = 0.10 Uc (at |
| Maximum operating rate | 3600 cyc/h |
| Coil technology | With integral suppression device |
| Auxiliary contacts type | type instantaneous 1 NO |
| Minimum switching current | 5 mA for control circuit |
| Minimum switching voltage | 17 V for control circuit |
| Mounting support | Rail; Plate |
| Operating time | 25...35 ms coil energisation and NC opening; 30...40 ms between energisation of coil and closing of NO contact; 10...20 ms coil de-energisation and NO opening; 15...25 ms coil de-energisation and NC opening |
| Mechanical durability | 30 Mcycles |
| Electrical durability | 1.3 Mcycles 6 A AC-3 at Ue |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Net weight | 0.235 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; GB/T 14048.4 |
| Product certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
| IP degree of protection | IP2X |
| Protective treatment | TC conforming to IEC 60068 |
| Ambient air temperature for operation | -25…50 °C |
| Ambient air temperature for storage | -50…80 °C |
| Operating altitude | 2000 m without derating |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | Class C2 conforming to NF F 16-101; Class C2 conforming to NF F 16-102; V1 conforming to UL 94 |
| Main |
| Range | TeSys |
| Product or component type | Contactor |
| Device short name | LP4K |
| Contactor application | Motor control |
| Quantity per set | Set of 10 |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.0 cm |
| Package 1 Width | 29.0 cm |
| Package 1 Length | 29.5 cm |
| Package 1 Weight | 220.0 g |
| Unit Type of Package 2 | CAR |
| Number of Units in Package 2 | 30 |
| Package 2 Height | 7.0 cm |
| Package 2 Width | 29.0 cm |
| Package 2 Length | 29.5 cm |
| Package 2 Weight | 6.62 kg |
The LP4K contactor from the TeSys series by Schneider Electric is a 3-pole contactor for motor control in industrial, infrastructure, and building technical applications. It has a rated operational current of 6 A at 400 V AC in category AC-3 and enables control of motors with a power of 2.2 kW under these conditions. The coil is designed for a control circuit voltage of 24 V DC and features low power consumption, with both pickup and holding power rated at 1.8 W at 20 °C. The integrated bidirectional amplitude-limiting diode ensures effective suppression of voltage spikes in the control circuit, increasing the coil's lifespan and control reliability.
Applications
This contactor is designed for applications in simple machine control, particularly in industrial environments, infrastructure projects, and building installations. It is suitable for use in control systems operated by electronic devices such as PLCs (Programmable Logic Controllers). Categories AC-3, AC-3e, and AC-4 cover various operating modes, including control of motors with high starting currents or frequent switching operations.
Functions and Equipment in Detail
The device features three normally open contacts in the main current circuit (3 S) and one additional auxiliary contact, also configured as a normally open contact (1 S). The auxiliary contacts are non-delayed and serve for signal transmission in control circuits. The rated impulse voltage withstand is 8 kV, ensuring high insulation strength against transient voltage spikes. The rated insulation voltage is 690 V for the current circuit and 690 V for the control circuit according to IEC and BS standards, with an insulation strength of 750 V for the control circuit specified under VDE Group C. The insulation resistance of the control circuit exceeds 10 MΩ.
Technology Explained Simply
The contactor coil operates with a control circuit voltage of 24 V DC and is designed for operation within a wide voltage range, with operating limits between 0.7 and 1.3 times the nominal voltage. The integrated suppression unit reduces electromagnetic interference generated when the coil is switched off. The mechanical life is 30 million switching cycles, while the electrical life is 1.3 million switching cycles at 6 A AC-3 and nominal voltage. The operating time is 25–35 ms for coil energization and NC opening, and 30–40 ms between energization and closure of the NO contact.
Compatibility and Accessories
The contactor is compatible with various motor protection circuit breakers from the GV2ME and GV2LE series, as well as with motor protection relays from the LR2K series. These components enable complete motor control with integrated overload protection. The mentioned accessories are available in various rated currents and configurations to cover different motor powers and protection requirements. Mounting is either on a rail or a plate, allowing flexible integration into existing control panels.
Mounting and Installation
Mounting is done on a standard rail holder (e.g., DIN rail) or directly on a mounting plate. Dimensions are 45 mm (width) × 58 mm (height) × 57 mm (depth), allowing integration into compact control enclosures. The product weight is 0.235 kg. Installation requires adherence to safety regulations, particularly disconnecting all power supplies before any maintenance or mounting to avoid risks of electric shock, explosion, or arc flash.
Operational Advantages
The contactor offers high reliability during frequent switching operations, thanks to its high mechanical and electrical life. The integrated suppression unit minimizes interference in the control circuit and protects the coil from voltage spikes. The low power consumption of the coil reduces energy usage and heat generation. Compatibility with various motor protection systems enables flexible and safe motor control across different application areas. Certifications according to GOST, CSA, UL, and compliance with standards such as IEC, VDE, BS, and NF C 63-110 ensure adherence to international safety and quality standards.