| Complementary |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at |
| Inrush power in W | 3 W (at 20 °C) |
| Hold-in power consumption in W | 3 W at 20 °C |
| Heat dissipation | 3 W |
| Auxiliary contacts type | type instantaneous 1 NC |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Non overlap distance | 0.5 mm |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| IP degree of protection | IP20 conforming to VDE 0106 |
| Protective treatment | TC conforming to IEC 60068; TC conforming to DIN 50016 |
| Ambient air temperature for operation | -25…50 °C |
| Ambient air temperature for storage | -50…80 °C |
| Operating altitude | 2000 m without derating |
| Flame retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
| Height | 58 mm |
| Width | 90 mm |
| Depth | 57 mm |
| Net weight | 0.48 kg |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys |
| Product name | TeSys K |
| Product or component type | Reversing contactor |
| Device short name | LP2K |
| Device application | Control |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-3e; AC-4; AC-1 |
| Device presentation | Preassembled with reversing power busbar |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: 690 V AC 50/60 Hz; Signalling circuit: |
| [Ie] rated operational current | 9 A (at |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz; 4 kW at 380...415 V AC 50/60 Hz; 4 kW at 440/690 V AC 50/60 Hz |
| Control circuit type | DC standard |
| [Uc] control circuit voltage | 24 V DC |
| Auxiliary contact composition | 1 NC |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
| Electrical durability | 1.3 Mcycles 9 A AC-3 at Ue |
| Interlocking type | Mechanical |
| Mounting support | Plate; Rail |
| Standards | EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1 |
| Product certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
| Tightening torque | 0.8…1.3 N.m - on screw clamp terminals Philips No 2; 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm; 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2 |
| Operating time | 30...40 ms coil energisation and NO closing; 10 ms coil de-energisation and NO opening |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 5 Mcycles |
| Maximum operating rate | 3600 cyc/h |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.500 cm |
| Package 1 Width | 9.300 cm |
| Package 1 Length | 6.000 cm |
| Package 1 Weight | 454.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 20 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 9.330 kg |
The
reversing contactor LP2K0901BD3 from the
TeSys K series by
Schneider Electric is a 3-pole contactor for controlling electric drives and resistive loads. It is specifically designed for motor control applications and supports power ratings up to 4 kW at 380–415 V AC (category AC-3) as well as at 440–690 V AC. The rating is based on a service rated current of 9 A in the circuit, with the maximum motor power varying between 2.2 kW and 4 kW depending on the voltage range. Control is achieved via a
24 V DC coil, equipped with an integrated bidirectional peak-limiting diode suppressor to limit voltage spikes in the control circuit and extend the coil’s service life.
Applications include industrial motor control, particularly in systems requiring reversible rotation, such as conveyor belts, pumps, or machine tools. The device is approved for use categories AC-1, AC-3, AC-3e, and AC-4, enabling broad applicability across various load types. The integrated
auxiliary contact arrangement with one normally open contact (1NO) allows direct integration into control circuits, for example, for status indication or feedback to a higher-level control system. The
mechanical interlock ensures that the contactors cannot be energized simultaneously, which is essential for reversing operations to prevent short circuits.
Functions and features in detail include a pre-assembled reversing power busbar, simplifying installation and wiring. Connections are made via
screw terminals, designed for cable cross-sections from 0.34 to 4 mm² (flexible or rigid), with tightening torques ranging from 0.8 to 1.3 Nm. The terminals are compatible with Phillips screwdrivers size 2, flat screws Ø 6 mm, and position 2. The
rated operating voltage in the circuit is 690 V AC at 50/60 Hz, with insulation strength at 690 V according to IEC 60947-4-1. The
rated impulse voltage withstand is 8 kV, and the overvoltage category is III, enabling use in industrial environments with high transient voltages.
Technology explained simply shows that the contactor is designed for high operational reliability. The
electrical service life is 1.3 million switching cycles at 9 A and AC-3 operation, while the
mechanical service life reaches 5 million cycles. The maximum operating rate is 3600 switching operations per hour, sufficient for high dynamics in control technology. Operating times are 30–40 ms for coil energization and NO closure, and 10 ms for coil de-energization and NO opening. The
rated short-time current withstand is defined for various durations, with the current value at 50 °C and 1 second being 90 A. The
rated breaking capacity is 110 A for voltage ranges up to 440 V and reduces to 70 A at 660–690 V, ensuring reliability during load interruption.
Compatibility and accessories include use with motor protection circuit breakers such as GV2ME14 or GV2LE14, as well as auxiliary switch blocks like LA1KN02, LA1KN22, or LA1KN31. These can be used to extend control functions, such as status feedback or interlocking. Certification according to
EN/IEC 60947-4-1 and additional standards such as UL 60947-4-1, CSA C22.2 No. 60947-4-1, and JIS C8201-4-1 ensures international usability. Product certifications include CB Scheme, CCC, UL, CSA, EAC, CE, and UKCA. The device is also suitable for safety applications, as it features a certified S-type mirror contact meeting safety level B10d = 1,369,863 cycles at rated load according to EN/ISO 13849-1.
Mounting and installation are performed on DIN rails or directly on a panel. The compact design with a width of 90 mm, height of 58 mm, and depth of 57 mm allows dense mounting in enclosures. The
mounting bracket is designed for both rail and panel mounting, offering flexibility during installation. The
associated protection is 25 A gG, ensuring safety in fault conditions. The
average impedance is 3 MΩ at a thermal current of 20 A and 50 Hz in the circuit.
Operational advantages include high reliability, long service life, and easy installation. The integrated diode in the coil reduces electromagnetic interference and extends the life of control components. Multi-standard certification enables use in various markets, and RoHS/REACH compliance ensures environmental compatibility. The contactor is designed for industrial environments where high mechanical and electrical stresses occur.
Key terms in the text:
reversing contactor,
TeSys K,
24 V DC coil,
S-type mirror contact,
DIN rail mounting,
AC-3.